LabGard ES AIR NU-543 Class II Type A2 Biosafety Cabinet

The NU-543 is configurable for a broad range of applications and geographies with a choice of NSF listed access openings, an optional smooth interior, EN 12469 listed configurations, and a global supply chain.

Overview

The NU-543 carries the LabGard® value proposition across the boundaries of geography and scientific applications by offering the broadest choice of configurations. This model features a dual thermistor airflow sensor and alphanumeric display for laboratories requiring a clear measurement of their cabinet’s performance and a choice of three NSF listed work access openings for procedures needing ergonomic access to the work zone. The cabinet can optionally be made with a smooth interior for procedures such as pharmacy compounding and always includes a prop up work tray to ease regular cleaning under the work surface. Double exhaust filters can be fitted to meet the requirements of an application or national guidelines. A truly global product, models are available that meet NSF/ANSI 49 and EN 12469, feature multilingual displays, and can ship from multiple locations around the world. * *Some options and configurations are only available from North America. Consult NuAire for details.

FlowGard Control System

The FlowGard control system calculates inflow velocity based on the data received from the exhaust airflow sensor and displays it on the front screen. Alphanumeric readouts, nearby membrane buttons, and a choice of 6 world languages all make navigating this system's user and service menus easy.

FlowGard Electronic Controls System for Laboratory Equipment

Choice of 3 Access Openings

A choice of 8, 10, and 12 inch (203, 254, and 305mm) work access openings that are NSF approved allow the user to configure their biosafety cabinet for their specific application while remaining confident of certified containment.

Choose from 3 access opening heights on a NU-543 Biosafety Cabinet.

Smooth Interior Option

The side and back walls made from one piece of steel already make routine wipe down easy. Go one step further and remove the work zone outlets and service valves to create the ultimate easy to clean steel surface appropriate for applications such as sterile drug compounding.

Biosafety Cabinet smooth interior for cleanability.

Specifications

LabGard NU-543 Class II, Type A2 Biosafety Cabinet
Blower Contact Wires Optional
Closure Panels Optional Rear Closure Panels for Seismic Brackets
Cord Pass Through Standard Right
Double Exhaust HEPA Filter N/A
Gas Supply Interlock with Blower N/A
Glass Sidewalls Optional with 8 or 10 inch (203 or 254mm) Work Access Openings
IV Bar with 6 Hooks Optional
Magnifying Glass in Window N/A
Motorized Base Stand Optional as Separate Accessory
Motorized Window N/A
Other Built-in Supply Filter Option(s) N/A
Outlet(s) Standard, two backwall
Plumbing Optional 3/8" Soft Copper, 3/8" Black Pipe (Gas Only), or 1/2" Rigid Copper
Remote Service Valves N/A
Seismic Brackets or Studs Optional Rear or Floor Mount Seismic Brackets
Service Couplings (3/8-inch NPT) Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Three Each Side Wall Optional
Service Valves (3/8-inch NPT) One Valve on Right Side Wall is Standard, Maximum of Three Each Side Wall Optional
Side Panels Optional with Plumbing out Bottom, Top or Back
Smooth Interior Optional
Ultraviolet (UV) Light Optional
Window Edge Protector Optional
Access Opening Glass Type Tempered
Armrest Standard Plastic with Optional Stainless Steel
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Casters N/A
Decontamination Seal-able Window N/A
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 11 1/2-inch (292 mm) 99.99% Efficiency on 0.3 microns
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Single Piece Stainless Steel Side and Back Wall Construction
Motor(s) 1/2 HP DC ECM
Plenum Type HEPEX
Pre-filter N/A
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.99% Efficiency on 0.3 microns
Viewing Window Inches (mm) 21 (533) open to fully closed
Work Access Opening(s) 8, 10, 12-inch (203, 254, 305 mm)
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 43 (1092)
Est. Shipping Height Inches (mm) 70 (1778)
Est. Shipping Width Inches (mm) 46 (1168)
Exterior Depth Inches (mm) 32 1/8 (817)
Exterior Depth with Armrest Removed Inches (mm) 31 7/16 (799)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 87.375 (2219)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 93.375 (2371)
Exterior Width Inches (mm) 41 5/8 (1057)
Nominal Width Feet (Meters) 3 ft. (0.9m)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 33 7/8 (860)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 25 3/4 (654)
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) Inquire
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) Inquire
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 34 3/8 (873)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 2.3
Blower/Lights Amps [12-inch (305 mm) Access Opening]
Blower/Lights Amps [14-inch (356mm) Access Opening]
Blower/Lights Amps [8-inch (203 mm) Access Opening] 2.1
Electrical Configuration 115V60Hz
Junction Box Optional
Outlet Amps 3
Power Cord 14 GA - 3 Wire, 15A
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 10
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 ≤ 55dba
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 320 (544)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 276-501 (649-851)
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 387 (650)
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 341-554 (576-933)
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 269 (457)
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 255-450 (383-765)
Bag In Bag Out N/A
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 903
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) Inquire
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) 826
Heat Rejected Vented (BTU/Hour) 120
Other Built-in Exhaust Option(s) N/A
Plant Duct Static Pressure Inches (mm) 0.05-0.1"/1.27-2.54mm H2O
Australian Test Method N/A
Performance Standard NSF-ANSI-49
Safety Certification UL, UL-C
Air Cleanliness (ISO 14644) ISO-Class-5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor SingleAirflowSensor
Control System FlowGard
Est. Shipping Weight lbs (kg) 460 lbs. / 209 kg.
Net Weight lbs (kg) 410 lbs. / 186 kg.
Blower Contact Wires Optional
Closure Panels Optional Rear Closure Panels for Seismic Brackets
Cord Pass Through Standard Right
Double Exhaust HEPA Filter Optional
Gas Supply Interlock with Blower N/A
Glass Sidewalls Optional
IV Bar with 6 Hooks Optional
Magnifying Glass in Window N/A
Motorized Base Stand Optional as Separate Accessory
Motorized Window N/A
Other Built-in Supply Filter Option(s) N/A
Outlet(s) Standard, two backwall
Plumbing Optional 3/8" Soft Copper, 3/8" Black Pipe (Gas Only), or 1/2" Rigid Copper
Remote Service Valves N/A
Seismic Brackets or Studs Optional Rear or Floor Mount Seismic Brackets
Service Couplings (3/8-inch NPT) Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Three Each Side Wall Optional
Service Valves (3/8-inch NPT) One Valve on Right Side Wall is Standard, Maximum of Three Each Side Wall Optional
Side Panels Optional with Plumbing out Bottom, Top or Back
Smooth Interior N/A
Ultraviolet (UV) Light Optional
Window Edge Protector Optional
Access Opening Glass Type Safety Glass
Armrest Standard Plastic with Optional Stainless Steel
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Casters N/A
Decontamination Seal-able Window N/A
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 11 1/2-inch (292 mm) 99.995% Efficiency @ MPPS
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Single Piece Stainless Steel Side and Back Wall Construction
Motor(s) 1/2 HP DC ECM
Plenum Type HEPEX
Pre-filter N/A
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.995% Efficiency @ MPPS
Viewing Window Inches (mm) 21 (533) open to fully closed
Work Access Opening(s) 10-inch (254 mm)
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 43 (1092)
Est. Shipping Height Inches (mm) 70 (1778)
Est. Shipping Width Inches (mm) 46 (1168)
Exterior Depth Inches (mm) 32 1/8 (817)
Exterior Depth with Armrest Removed Inches (mm) 31 7/16 (799)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 88 3/8 (2245)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 94 3/8 (2397)
Exterior Width Inches (mm) 41 5/8 (1057)
Nominal Width Feet (Meters) 3 ft. (0.9m)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 33 7/8 (860)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 25 3/4 (654)
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) N/A
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 34 3/8 (873)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 2.3
Blower/Lights Amps [12-inch (305 mm) Access Opening]
Blower/Lights Amps [14-inch (356mm) Access Opening]
Blower/Lights Amps [8-inch (203 mm) Access Opening]
Electrical Configuration 230V5060Hz
Junction Box Optional
Outlet Amps 3
Power Cord 14 GA - 3 Wire, 15A
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 8
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 ≤ 55dba
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 320 (544)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 276-501 (649-851)
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
Bag In Bag Out N/A
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 903
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) N/A
Heat Rejected Vented (BTU/Hour) 120
Other Built-in Exhaust Option(s) N/A
Plant Duct Static Pressure Inches (mm) 0.05-0.1"/1.27-2.54mm H2O
Australian Test Method Optional
Performance Standard NSF-ANSI-49, EN-12469
Safety Certification
Air Cleanliness (ISO 14644) ISO-Class-5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor SingleAirflowSensor
Control System FlowGard
Est. Shipping Weight lbs (kg) 460 lbs. / 209 kg.
Net Weight lbs (kg) 410 lbs. / 186 kg.
Blower Contact Wires N/A
Closure Panels N/A
Cord Pass Through Standard Right
Double Exhaust HEPA Filter N/A
Gas Supply Interlock with Blower N/A
Glass Sidewalls N/A
IV Bar with 6 Hooks Optional
Magnifying Glass in Window N/A
Motorized Base Stand Optional as Separate Accessory
Motorized Window N/A
Other Built-in Supply Filter Option(s) N/A
Outlet(s) Standard, two backwall
Plumbing N/A
Remote Service Valves N/A
Seismic Brackets or Studs N/A
Service Couplings (3/8-inch NPT) Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Two Each Side Wall Optional
Service Valves (3/8-inch NPT) One Valve on Right Side Wall is Standard, Maximum of Two Each Side Wall Optional
Side Panels N/A
Smooth Interior N/A
Ultraviolet (UV) Light Optional
Window Edge Protector N/A
Access Opening Glass Type Safety Glass
Armrest Plastic
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Casters N/A
Decontamination Seal-able Window N/A
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 11 1/2-inch (292 mm) 99.995% Efficiency @ MPPS
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Seam Welded Stainless Steel Side and Back Wall Construction
Motor(s) 1/2 HP DC ECM
Plenum Type HEPEX
Pre-filter N/A
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.995% Efficiency @ MPPS
Viewing Window Inches (mm) 21 (533) open to fully closed
Work Access Opening(s) 10-inch (254 mm)
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 41.3 (1050mm)
Est. Shipping Height Inches (mm) 76.8 (1950mm)
Est. Shipping Width Inches (mm) 49.2 (1250mm)
Exterior Depth Inches (mm) 32 3/16 (817)
Exterior Depth with Armrest Removed Inches (mm) 31 7/16 (799)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 87 3/8 (2219)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 93 3/8 (2372)
Exterior Width Inches (mm) 41 5/8 (1057)
Nominal Width Feet (Meters) 3 ft. (0.9m)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 33 7/8 (860)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 25 3/4 (654)
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) N/A
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 34 3/8 (873)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 2.3
Blower/Lights Amps [12-inch (305 mm) Access Opening]
Blower/Lights Amps [14-inch (356mm) Access Opening]
Blower/Lights Amps [8-inch (203 mm) Access Opening]
Electrical Configuration 100V5060Hz
Junction Box N/A
Outlet Amps 2
Power Cord 14 GA - 3 Wire, 15A
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 7
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 Inquire
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 320 (544)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 276-501 (649-851)
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
Bag In Bag Out N/A
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 903
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) N/A
Heat Rejected Vented (BTU/Hour) 120
Other Built-in Exhaust Option(s) N/A
Plant Duct Static Pressure Inches (mm) 0.05-0.1"/1.27-2.54mm H2O
Australian Test Method N/A
Performance Standard NSF-ANSI-49
Safety Certification UL, UL-C
Air Cleanliness (ISO 14644) ISO-Class-5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor SingleAirflowSensor
Control System FlowGard
Est. Shipping Weight lbs (kg) 460 lbs. / 209 kg.
Net Weight lbs (kg) 410 lbs. / 186 kg.
Blower Contact Wires N/A
Closure Panels N/A
Cord Pass Through Standard Right
Double Exhaust HEPA Filter N/A
Gas Supply Interlock with Blower N/A
Glass Sidewalls N/A
IV Bar with 6 Hooks Optional
Magnifying Glass in Window N/A
Motorized Base Stand Optional as Separate Accessory
Motorized Window N/A
Other Built-in Supply Filter Option(s) N/A
Outlet(s) Standard, two backwall
Plumbing N/A
Remote Service Valves N/A
Seismic Brackets or Studs N/A
Service Couplings (3/8-inch NPT) Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Two Each Side Wall Optional
Service Valves (3/8-inch NPT) One Valve on Right Side Wall is Standard, Maximum of Two Each Side Wall Optional
Side Panels N/A
Smooth Interior N/A
Ultraviolet (UV) Light Optional
Window Edge Protector N/A
Access Opening Glass Type Safety Glass
Armrest Plastic
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Casters N/A
Decontamination Seal-able Window N/A
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 11 1/2-inch (292 mm) 99.995% Efficiency @ MPPS
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Seam Welded Stainless Steel Side and Back Wall Construction
Motor(s) 1/2 HP DC ECM
Plenum Type HEPEX
Pre-filter N/A
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.995% Efficiency @ MPPS
Viewing Window Inches (mm) 21 (533) open to fully closed
Work Access Opening(s) 10-inch (254 mm)
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 41.3 (1050mm)
Est. Shipping Height Inches (mm) 76.8 (1950mm)
Est. Shipping Width Inches (mm) 49.2 (1250mm)
Exterior Depth Inches (mm) 32 3/16 (817)
Exterior Depth with Armrest Removed Inches (mm) 31 7/16 (799)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 87 3/8 (2219)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 93 3/8 (2372)
Exterior Width Inches (mm) 41 5/8 (1057)
Nominal Width Feet (Meters) 3 ft. (0.9m)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 33 7/8 (860)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 25 3/4 (654)
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) N/A
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 34 3/8 (873)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 2.3
Blower/Lights Amps [12-inch (305 mm) Access Opening]
Blower/Lights Amps [14-inch (356mm) Access Opening]
Blower/Lights Amps [8-inch (203 mm) Access Opening]
Electrical Configuration 115V60Hz
Junction Box N/A
Outlet Amps 3
Power Cord 14 GA - 3 Wire, 15A
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 10
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 Inquire
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 320 (544)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 276-501 (649-851)
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
Bag In Bag Out N/A
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 903
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) N/A
Heat Rejected Vented (BTU/Hour) 120
Other Built-in Exhaust Option(s) N/A
Plant Duct Static Pressure Inches (mm) 0.05-0.1"/1.27-2.54mm H2O
Australian Test Method N/A
Performance Standard NSF-ANSI-49
Safety Certification UL, UL-C
Air Cleanliness (ISO 14644) ISO-Class-5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor SingleAirflowSensor
Control System FlowGard
Est. Shipping Weight lbs (kg) 460 (209)
Net Weight lbs (kg) 410 (186)
Blower Contact Wires N/A
Closure Panels N/A
Cord Pass Through Standard Right
Double Exhaust HEPA Filter Optional
Gas Supply Interlock with Blower N/A
Glass Sidewalls N/A
IV Bar with 6 Hooks Optional
Magnifying Glass in Window N/A
Motorized Base Stand Optional as Separate Accessory
Motorized Window N/A
Other Built-in Supply Filter Option(s) N/A
Outlet(s) Standard, two backwall
Plumbing N/A
Remote Service Valves N/A
Seismic Brackets or Studs N/A
Service Couplings (3/8-inch NPT) Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Two Each Side Wall Optional
Service Valves (3/8-inch NPT) One Valve on Right Side Wall is Standard, Maximum of Two Each Side Wall Optional
Side Panels N/A
Smooth Interior N/A
Ultraviolet (UV) Light Optional
Window Edge Protector N/A
Access Opening Glass Type Safety Glass
Armrest Plastic
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Casters N/A
Decontamination Seal-able Window N/A
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 11 1/2-inch (292 mm) 99.995% Efficiency @ MPPS
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Seam Welded Stainless Steel Side and Back Wall Construction
Motor(s) 1/2 HP DC ECM
Plenum Type HEPEX
Pre-filter N/A
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.995% Efficiency @ MPPS
Viewing Window Inches (mm) 21 (533) open to fully closed
Work Access Opening(s) 10-inch (254 mm)
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 41.3 (1050mm)
Est. Shipping Height Inches (mm) 76.8 (1950mm)
Est. Shipping Width Inches (mm) 49.2 (1250mm)
Exterior Depth Inches (mm) 32 3/16 (817)
Exterior Depth with Armrest Removed Inches (mm) 31 7/16 (799)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 87 3/8 (2219)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 93 3/8 (2372)
Exterior Width Inches (mm) 41 5/8 (1056)
Nominal Width Feet (Meters) 3 ft. (0.9m)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 33 7/8 (860)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 25 3/4 (654)
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) N/A
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 34 3/8 (872)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 2.3
Blower/Lights Amps [12-inch (305 mm) Access Opening]
Blower/Lights Amps [14-inch (356mm) Access Opening]
Blower/Lights Amps [8-inch (203 mm) Access Opening]
Electrical Configuration 230V5060Hz
Junction Box N/A
Outlet Amps 3
Power Cord Single 12-foot (3.7m) 14 GA - 3 Wire, 15A
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 8
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 ≤ 55dba
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 320 (544)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 276-501 (649-851)
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
Bag In Bag Out N/A
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 903
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) N/A
Heat Rejected Vented (BTU/Hour) 120
Other Built-in Exhaust Option(s) N/A
Plant Duct Static Pressure Inches (mm) 0.05-0.1" (1.27-2.54)
Australian Test Method Optional
Performance Standard NSF-ANSI-49, EN-12469
Safety Certification UL, UL-C
Air Cleanliness (ISO 14644) ISO-Class-5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor SingleAirflowSensor
Control System FlowGard
Est. Shipping Weight lbs (kg) 460 (209)
Net Weight lbs (kg) 410 (186)
Blower Contact Wires Optional
Closure Panels Optional Rear Closure Panels for Seismic Brackets
Cord Pass Through Standard Right
Double Exhaust HEPA Filter N/A
Gas Supply Interlock with Blower N/A
Glass Sidewalls Optional with 8 or 10 inch (203 or 254mm) Work Access Openings
IV Bar with 6 Hooks Optional
Magnifying Glass in Window N/A
Motorized Base Stand Optional as Separate Accessory
Motorized Window N/A
Other Built-in Supply Filter Option(s) N/A
Outlet(s) Standard, two backwall
Plumbing Optional 3/8" Soft Copper, 3/8" Black Pipe (Gas Only), or 1/2" Rigid Copper
Remote Service Valves N/A
Seismic Brackets or Studs Optional Rear or Floor Mount Seismic Brackets
Service Couplings (3/8-inch NPT) Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Three Each Side Wall Optional
Service Valves (3/8-inch NPT) One Valve on Right Side Wall is Standard, Maximum of Three Each Side Wall Optional
Side Panels Optional with Plumbing out Bottom, Top or Back
Smooth Interior Optional
Ultraviolet (UV) Light Optional
Window Edge Protector Optional
Access Opening Glass Type Tempered
Armrest Standard Plastic with Optional Stainless Steel
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Casters N/A
Decontamination Seal-able Window N/A
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 11 1/2-inch (292 mm) 99.99% Efficiency on 0.3 microns
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Single Piece Stainless Steel Side and Back Wall Construction
Motor(s) 3/4 HP DC ECM
Plenum Type HEPEX
Pre-filter N/A
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.99% Efficiency on 0.3 microns
Viewing Window Inches (mm) 21 (533) open to fully closed
Work Access Opening(s) 8, 10, 12-inch (203, 254, 305 mm)
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 43 (1092)
Est. Shipping Height Inches (mm) 70 (1778)
Est. Shipping Width Inches (mm) 58 (1473)
Exterior Depth Inches (mm) 32 1/8 (817)
Exterior Depth with Armrest Removed Inches (mm) 31 7/16 (799)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 87.375 (2219)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 93.375 (2371)
Exterior Width Inches (mm) 53 5/8 (1362)
Nominal Width Feet (Meters) 4 (1.2)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 45 7/8 (1165)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 25 3/4 (654)
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) Inquire
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) Inquire
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 46 3/8 (1178)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 2.9
Blower/Lights Amps [12-inch (305 mm) Access Opening] 3.2
Blower/Lights Amps [14-inch (356mm) Access Opening]
Blower/Lights Amps [8-inch (203 mm) Access Opening] 2.6
Electrical Configuration 115V60Hz
Junction Box Optional
Outlet Amps 3
Power Cord 12 gauge - 3 Wire, 20A
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 14
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 ≤ 56 dba
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 426 (724)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 363-588 (617-1000)
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 483 (821)
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 430-655 (731-1113)
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 359 (610)
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 295-520 (502-884)
Bag In Bag Out N/A
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 1140
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) 1256
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) 1020
Heat Rejected Vented (BTU/Hour) 157
Other Built-in Exhaust Option(s) N/A
Plant Duct Static Pressure Inches (mm) 0.05-0.1"/1.27-2.54mm H2O
Australian Test Method N/A
Performance Standard NSF-ANSI-49
Safety Certification UL, UL-C
Air Cleanliness (ISO 14644) ISO-Class-5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor SingleAirflowSensor
Control System FlowGard
Est. Shipping Weight lbs (kg) 530 lbs. / 240 kg.
Net Weight lbs (kg) 480 lbs. / 218 kg.
Blower Contact Wires Optional
Closure Panels Optional Rear Closure Panels for Seismic Brackets
Cord Pass Through Standard Right
Double Exhaust HEPA Filter Optional
Gas Supply Interlock with Blower N/A
Glass Sidewalls Optional
IV Bar with 6 Hooks Optional
Magnifying Glass in Window N/A
Motorized Base Stand Optional as Separate Accessory
Motorized Window N/A
Other Built-in Supply Filter Option(s) N/A
Outlet(s) Standard, two backwall
Plumbing Optional 3/8" Soft Copper, 3/8" Black Pipe (Gas Only), or 1/2" Rigid Copper
Remote Service Valves N/A
Seismic Brackets or Studs Optional Rear or Floor Mount Seismic Brackets
Service Couplings (3/8-inch NPT) Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Three Each Side Wall Optional
Service Valves (3/8-inch NPT) One Valve on Right Side Wall is Standard, Maximum of Three Each Side Wall Optional
Side Panels Optional with Plumbing out Bottom, Top or Back
Smooth Interior N/A
Ultraviolet (UV) Light Optional
Window Edge Protector Optional
Access Opening Glass Type Safety Glass
Armrest Standard Plastic with Optional Stainless Steel
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Casters N/A
Decontamination Seal-able Window N/A
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 11 1/2-inch (292 mm) 99.995% Efficiency @ MPPS
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Single Piece Stainless Steel Side and Back Wall Construction
Motor(s) 3/4 HP DC ECM
Plenum Type HEPEX
Pre-filter N/A
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.995% Efficiency @ MPPS
Viewing Window Inches (mm) 21 (533) open to fully closed
Work Access Opening(s) 10-inch (254 mm)
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 43 (1092)
Est. Shipping Height Inches (mm) 70 (1778)
Est. Shipping Width Inches (mm) 58 (1473)
Exterior Depth Inches (mm) 32 1/8 (817)
Exterior Depth with Armrest Removed Inches (mm) 31 7/16 (799)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 88 3/8 (2245)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 94 3/8 (2397)
Exterior Width Inches (mm) 53 5/8 (1362)
Nominal Width Feet (Meters) 4 ft. (1.2m)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 45 7/8 (1165)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 25 3/4 (654)
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) N/A
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 46 3/8 (1178)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 2.9
Blower/Lights Amps [12-inch (305 mm) Access Opening]
Blower/Lights Amps [14-inch (356mm) Access Opening]
Blower/Lights Amps [8-inch (203 mm) Access Opening]
Electrical Configuration 230V5060Hz
Junction Box Optional
Outlet Amps 3
Power Cord 14 gauge - 3 Wire, 15A
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 10
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 ≤ 56 dba
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 426 (724)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 363-588 (617-1000)
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
Bag In Bag Out N/A
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 1140
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) N/A
Heat Rejected Vented (BTU/Hour) 157
Other Built-in Exhaust Option(s) N/A
Plant Duct Static Pressure Inches (mm) 0.05-0.1"/1.27-2.54mm H2O
Australian Test Method Optional
Performance Standard NSF-ANSI-49, EN-12469
Safety Certification
Air Cleanliness (ISO 14644) ISO-Class-5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor SingleAirflowSensor
Control System FlowGard
Est. Shipping Weight lbs (kg) 530 lbs. / 240 kg.
Net Weight lbs (kg) 480 lbs. / 218 kg.
Blower Contact Wires N/A
Closure Panels N/A
Cord Pass Through Standard Right
Double Exhaust HEPA Filter N/A
Gas Supply Interlock with Blower N/A
Glass Sidewalls N/A
IV Bar with 6 Hooks Optional
Magnifying Glass in Window N/A
Motorized Base Stand Optional as Separate Accessory
Motorized Window N/A
Other Built-in Supply Filter Option(s) N/A
Outlet(s) Standard, two backwall
Plumbing N/A
Remote Service Valves N/A
Seismic Brackets or Studs N/A
Service Couplings (3/8-inch NPT) Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Two Each Side Wall Optional
Service Valves (3/8-inch NPT) One Valve on Right Side Wall is Standard, Maximum of Two Each Side Wall Optional
Side Panels N/A
Smooth Interior N/A
Ultraviolet (UV) Light Optional
Window Edge Protector N/A
Access Opening Glass Type Safety Glass
Armrest Plastic
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Casters N/A
Decontamination Seal-able Window N/A
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 11 1/2-inch (292 mm) 99.995% Efficiency @ MPPS
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Seam Welded Stainless Steel Side and Back Wall Construction
Motor(s) 3/4 HP DC ECM
Plenum Type HEPEX
Pre-filter N/A
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.995% Efficiency @ MPPS
Viewing Window Inches (mm) 21 (533) open to fully closed
Work Access Opening(s) 10-inch (254 mm)
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 41.3 (1050mm)
Est. Shipping Height Inches (mm) 76.8 (1950mm)
Est. Shipping Width Inches (mm) 57.1 (1450)
Exterior Depth Inches (mm) 32 3/16 (817)
Exterior Depth with Armrest Removed Inches (mm) 31 7/16 (799)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 87 3/8 (2219)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 93 3/8 (2372)
Exterior Width Inches (mm) 53 5/8 (1362)
Nominal Width Feet (Meters) 4 ft. (1.2m)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 45 7/8 (1165)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 25 3/4 (654)
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) N/A
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 46 3/8 (1178)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 2.9
Blower/Lights Amps [12-inch (305 mm) Access Opening]
Blower/Lights Amps [14-inch (356mm) Access Opening]
Blower/Lights Amps [8-inch (203 mm) Access Opening]
Electrical Configuration 100V5060Hz
Junction Box N/A
Outlet Amps 2
Power Cord 12 GA - 3 Wire, 20A
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 11
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 Inquire
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 426 (724)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 363-588 (617-1000)
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
Bag In Bag Out N/A
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 1140
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) N/A
Heat Rejected Vented (BTU/Hour) 157
Other Built-in Exhaust Option(s) N/A
Plant Duct Static Pressure Inches (mm) 0.05-0.1"/1.27-2.54mm H2O
Australian Test Method N/A
Performance Standard NSF-ANSI-49
Safety Certification UL, UL-C
Air Cleanliness (ISO 14644) ISO-Class-5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor SingleAirflowSensor
Control System FlowGard
Est. Shipping Weight lbs (kg) 530 (240)
Net Weight lbs (kg) 480 (218)
Blower Contact Wires N/A
Closure Panels N/A
Cord Pass Through Standard Right
Double Exhaust HEPA Filter N/A
Gas Supply Interlock with Blower N/A
Glass Sidewalls N/A
IV Bar with 6 Hooks Optional
Magnifying Glass in Window N/A
Motorized Base Stand Optional as Separate Accessory
Motorized Window N/A
Other Built-in Supply Filter Option(s) N/A
Outlet(s) Standard, two backwall
Plumbing N/A
Remote Service Valves N/A
Seismic Brackets or Studs N/A
Service Couplings (3/8-inch NPT) Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Two Each Side Wall Optional
Service Valves (3/8-inch NPT) One Valve on Right Side Wall is Standard, Maximum of Two Each Side Wall Optional
Side Panels N/A
Smooth Interior N/A
Ultraviolet (UV) Light Optional
Window Edge Protector N/A
Access Opening Glass Type Safety Glass
Armrest Plastic
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Casters N/A
Decontamination Seal-able Window N/A
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 11 1/2-inch (292 mm) 99.995% Efficiency @ MPPS
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Seam Welded Stainless Steel Side and Back Wall Construction
Motor(s) 3/4 HP DC ECM
Plenum Type HEPEX
Pre-filter N/A
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.995% Efficiency @ MPPS
Viewing Window Inches (mm) 21 (533) open to fully closed
Work Access Opening(s) 10-inch (254 mm)
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 41.3 (1050mm)
Est. Shipping Height Inches (mm) 76.8 (1950mm)
Est. Shipping Width Inches (mm) 57.1 (1450)
Exterior Depth Inches (mm) 32 3/16 (817)
Exterior Depth with Armrest Removed Inches (mm) 31 7/16 (799)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 87 3/8 (2219)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 93 3/8 (2372)
Exterior Width Inches (mm) 53 5/8 (1362)
Nominal Width Feet (Meters) 4 ft. (1.2m)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 45 7/8 (1165)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 25 3/4 (654)
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) N/A
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 46 3/8 (1178)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 2.9
Blower/Lights Amps [12-inch (305 mm) Access Opening]
Blower/Lights Amps [14-inch (356mm) Access Opening]
Blower/Lights Amps [8-inch (203 mm) Access Opening]
Electrical Configuration 115V60Hz
Junction Box N/A
Outlet Amps 3
Power Cord 12 GA - 3 Wire, 20A
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 14
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 Inquire
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 426 (724)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 363-588 (617-1000)
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
Bag In Bag Out N/A
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 1140
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) N/A
Heat Rejected Vented (BTU/Hour) 157
Other Built-in Exhaust Option(s) N/A
Plant Duct Static Pressure Inches (mm) 0.05-0.1"/1.27-2.54mm H2O
Australian Test Method N/A
Performance Standard NSF-ANSI-49
Safety Certification UL, UL-C
Air Cleanliness (ISO 14644) ISO-Class-5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor SingleAirflowSensor
Control System FlowGard
Est. Shipping Weight lbs (kg) 530 (240)
Net Weight lbs (kg) 480 (218)
Blower Contact Wires N/A
Closure Panels N/A
Cord Pass Through Standard Right
Double Exhaust HEPA Filter Optional
Gas Supply Interlock with Blower N/A
Glass Sidewalls N/A
IV Bar with 6 Hooks Optional
Magnifying Glass in Window N/A
Motorized Base Stand Optional as Separate Accessory
Motorized Window N/A
Other Built-in Supply Filter Option(s) N/A
Outlet(s) Standard, two backwall
Plumbing N/A
Remote Service Valves N/A
Seismic Brackets or Studs N/A
Service Couplings (3/8-inch NPT) Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Two Each Side Wall Optional
Service Valves (3/8-inch NPT) One Valve on Right Side Wall is Standard, Maximum of Two Each Side Wall Optional
Side Panels N/A
Smooth Interior N/A
Ultraviolet (UV) Light Optional
Window Edge Protector N/A
Access Opening Glass Type Safety Glass
Armrest Plastic
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Casters N/A
Decontamination Seal-able Window N/A
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 11 1/2-inch (292 mm) 99.995% Efficiency @ MPPS
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Seam Welded Stainless Steel Side and Back Wall Construction
Motor(s) 3/4 HP DC ECM
Plenum Type HEPEX
Pre-filter N/A
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.995% Efficiency @ MPPS
Viewing Window Inches (mm) 21 (533) open to fully closed
Work Access Opening(s) 10-inch (254 mm)
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 41.3 (1050mm)
Est. Shipping Height Inches (mm) 76.8 (1950mm)
Est. Shipping Width Inches (mm) 57.1 (1450)
Exterior Depth Inches (mm) 32 3/16 (817)
Exterior Depth with Armrest Removed Inches (mm) 31 7/16 (799)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 87 3/8 (2219)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 93 3/8 (2372)
Exterior Width Inches (mm) 53 5/8 (1362)
Nominal Width Feet (Meters) 4 ft. (1.2m)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 45 7/8 (1165)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 25 3/4 (654)
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) N/A
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 46 3/8 (1178)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 2.9
Blower/Lights Amps [12-inch (305 mm) Access Opening]
Blower/Lights Amps [14-inch (356mm) Access Opening]
Blower/Lights Amps [8-inch (203 mm) Access Opening]
Electrical Configuration 230V5060Hz
Junction Box N/A
Outlet Amps 3
Power Cord Single 12-foot (3.7m) 14 GA - 3 Wire, 15A
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 10
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 ≤ 56dba
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 426 (724)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 363-588 (617-1000)
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
Bag In Bag Out N/A
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 1140
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) N/A
Heat Rejected Vented (BTU/Hour) 157
Other Built-in Exhaust Option(s) N/A
Plant Duct Static Pressure Inches (mm) 0.05-0.1" (1.27-2.54)
Australian Test Method Optional
Performance Standard NSF-ANSI-49, EN-12469
Safety Certification UL, UL-C
Air Cleanliness (ISO 14644) ISO-Class-5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor SingleAirflowSensor
Control System FlowGard
Est. Shipping Weight lbs (kg) 530 (240)
Net Weight lbs (kg) 480 (218)
Blower Contact Wires Optional
Closure Panels Optional Rear Closure Panels for Seismic Brackets
Cord Pass Through Standard Right
Double Exhaust HEPA Filter N/A
Gas Supply Interlock with Blower N/A
Glass Sidewalls Optional with 8 or 10 inch (203 or 254mm) Work Access Openings
IV Bar with 6 Hooks Optional
Magnifying Glass in Window N/A
Motorized Base Stand Optional as Separate Accessory
Motorized Window N/A
Other Built-in Supply Filter Option(s) N/A
Outlet(s) Standard, two backwall
Plumbing Optional 3/8" Soft Copper, 3/8" Black Pipe (Gas Only), or 1/2" Rigid Copper
Remote Service Valves N/A
Seismic Brackets or Studs Optional Rear or Floor Mount Seismic Brackets
Service Couplings (3/8-inch NPT) Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Three Each Side Wall Optional
Service Valves (3/8-inch NPT) One Valve on Right Side Wall is Standard, Maximum of Three Each Side Wall Optional
Side Panels Optional with Plumbing out Bottom, Top or Back
Smooth Interior Optional
Ultraviolet (UV) Light Optional
Window Edge Protector Optional
Access Opening Glass Type Tempered
Armrest Standard Plastic with Optional Stainless Steel
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Casters N/A
Decontamination Seal-able Window N/A
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 11 1/2-inch (292 mm) 99.99% Efficiency on 0.3 microns
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Single Piece Stainless Steel Side and Back Wall Construction
Motor(s) 1 HP DC ECM
Plenum Type HEPEX
Pre-filter N/A
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.99% Efficiency on 0.3 microns
Viewing Window Inches (mm) 21 (533) open to fully closed
Work Access Opening(s) 8, 10, 12-inch (203, 254, 305 mm)
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 43 (1092)
Est. Shipping Height Inches (mm) 70 (1778)
Est. Shipping Width Inches (mm) 70 (1778)
Exterior Depth Inches (mm) 32 1/8 (817)
Exterior Depth with Armrest Removed Inches (mm) 31 7/16 (799)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 87.375 (2219)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 93.375 (2371)
Exterior Width Inches (mm) 65 5/8 (1669)
Nominal Width Feet (Meters) 5 ft. (1.5m)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 57 7/8 (1470)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 25 3/4 (654)
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) Inquire
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) Inquire
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 46 3/8 (1178)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 4.5
Blower/Lights Amps [12-inch (305 mm) Access Opening] 4.8
Blower/Lights Amps [14-inch (356mm) Access Opening]
Blower/Lights Amps [8-inch (203 mm) Access Opening] 4.1
Electrical Configuration 115V60Hz
Junction Box Optional
Outlet Amps 3
Power Cord 12 gauge - 3 Wire, 20A
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 16
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 ≤ 58
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 531 (902)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 451-676 (766-1149)
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 610 (1036)
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 531-760 (909-1291)
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 445 (756)
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 365-590 (621-1003)
Bag In Bag Out N/A
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 1768
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) 1884
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) 1611
Heat Rejected Vented (BTU/Hour) 198
Other Built-in Exhaust Option(s) N/A
Plant Duct Static Pressure Inches (mm) 0.05-0.1"/1.27-2.54mm H2O
Australian Test Method N/A
Performance Standard NSF-ANSI-49
Safety Certification UL, UL-C
Air Cleanliness (ISO 14644) ISO-Class-5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor SingleAirflowSensor
Control System FlowGard
Est. Shipping Weight lbs (kg) 620 lbs. / 281 kg.
Net Weight lbs (kg) 570 lbs. / 258 kg.
Blower Contact Wires Optional
Closure Panels Optional Rear Closure Panels for Seismic Brackets
Cord Pass Through Standard Right
Double Exhaust HEPA Filter Optional
Gas Supply Interlock with Blower N/A
Glass Sidewalls Optional
IV Bar with 6 Hooks Optional
Magnifying Glass in Window N/A
Motorized Base Stand Optional as Separate Accessory
Motorized Window N/A
Other Built-in Supply Filter Option(s) N/A
Outlet(s) Standard, two backwall
Plumbing Optional 3/8" Soft Copper, 3/8" Black Pipe (Gas Only), or 1/2" Rigid Copper
Remote Service Valves N/A
Seismic Brackets or Studs Optional Rear or Floor Mount Seismic Brackets
Service Couplings (3/8-inch NPT) Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Three Each Side Wall Optional
Service Valves (3/8-inch NPT) One Valve on Right Side Wall is Standard, Maximum of Three Each Side Wall Optional
Side Panels Optional with Plumbing out Bottom, Top or Back
Smooth Interior N/A
Ultraviolet (UV) Light Optional
Window Edge Protector Optional
Access Opening Glass Type Safety Glass
Armrest Standard Plastic with Optional Stainless Steel
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Casters N/A
Decontamination Seal-able Window N/A
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 11 1/2-inch (292 mm) 99.995% Efficiency @ MPPS
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Single Piece Stainless Steel Side and Back Wall Construction
Motor(s) 1 HP DC ECM
Plenum Type HEPEX
Pre-filter N/A
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.995% Efficiency @ MPPS
Viewing Window Inches (mm) 21 (533) open to fully closed
Work Access Opening(s) 10-inch (254 mm)
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 43 (1092)
Est. Shipping Height Inches (mm) 70 (1778)
Est. Shipping Width Inches (mm) 70 (1778)
Exterior Depth Inches (mm) 32 1/8 (817)
Exterior Depth with Armrest Removed Inches (mm) 31 7/16 (799)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 88 3/8 (2245)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 94 3/8 (2397)
Exterior Width Inches (mm) 65 5/8 (1669)
Nominal Width Feet (Meters) 5 ft. (1.5m)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 57 7/8 (1470)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 25 3/4 (654)
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) N/A
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 46 3/8 (1178)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 4.5
Blower/Lights Amps [12-inch (305 mm) Access Opening]
Blower/Lights Amps [14-inch (356mm) Access Opening]
Blower/Lights Amps [8-inch (203 mm) Access Opening]
Electrical Configuration 230V5060Hz
Junction Box Optional
Outlet Amps 3
Power Cord 14 gauge - 3 Wire, 15A
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 11
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 ≤ 58
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 531 (902)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 451-676 (766-1149)
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
Bag In Bag Out N/A
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 1768
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) N/A
Heat Rejected Vented (BTU/Hour) 198
Other Built-in Exhaust Option(s) N/A
Plant Duct Static Pressure Inches (mm) 0.05-0.1"/1.27-2.54mm H2O
Australian Test Method Optional
Performance Standard NSF-ANSI-49, EN-12469
Safety Certification
Air Cleanliness (ISO 14644) ISO-Class-5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor SingleAirflowSensor
Control System FlowGard
Est. Shipping Weight lbs (kg) 620 lbs. / 281 kg.
Net Weight lbs (kg) 570 lbs. / 258 kg.
Blower Contact Wires N/A
Closure Panels N/A
Cord Pass Through Standard Right
Double Exhaust HEPA Filter N/A
Gas Supply Interlock with Blower N/A
Glass Sidewalls N/A
IV Bar with 6 Hooks Optional
Magnifying Glass in Window N/A
Motorized Base Stand Optional as Separate Accessory
Motorized Window N/A
Other Built-in Supply Filter Option(s) N/A
Outlet(s) Standard, two backwall
Plumbing N/A
Remote Service Valves N/A
Seismic Brackets or Studs N/A
Service Couplings (3/8-inch NPT) Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Two Each Side Wall Optional
Service Valves (3/8-inch NPT) One Valve on Right Side Wall is Standard, Maximum of Two Each Side Wall Optional
Side Panels N/A
Smooth Interior N/A
Ultraviolet (UV) Light Optional
Window Edge Protector N/A
Access Opening Glass Type Safety Glass
Armrest Plastic
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Casters N/A
Decontamination Seal-able Window N/A
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 11 1/2-inch (292 mm) 99.995% Efficiency @ MPPS
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Seam Welded Stainless Steel Side and Back Wall Construction
Motor(s) 1 HP DC ECM
Plenum Type HEPEX
Pre-filter N/A
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.995% Efficiency @ MPPS
Viewing Window Inches (mm) 21 (533) open to fully closed
Work Access Opening(s) 10-inch (254 mm)
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 41.3 (1050mm)
Est. Shipping Height Inches (mm) 76.8 (1950mm)
Est. Shipping Width Inches (mm) 74.8 (1900)
Exterior Depth Inches (mm) 32 3/16 (817)
Exterior Depth with Armrest Removed Inches (mm) 31 7/16 (799)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 87 3/8 (2219)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 93 3/8 (2372)
Exterior Width Inches (mm) 65 5/8 (1669)
Nominal Width Feet (Meters) 5 ft. (1.5m)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 57 7/8 (1470)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 25 3/4 (654)
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) N/A
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 58 3/8 (1483)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 4.5
Blower/Lights Amps [12-inch (305 mm) Access Opening]
Blower/Lights Amps [14-inch (356mm) Access Opening]
Blower/Lights Amps [8-inch (203 mm) Access Opening]
Electrical Configuration 100V5060Hz
Junction Box N/A
Outlet Amps 2
Power Cord 12 GA - 3 Wire, 20A
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 13
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 Inquire
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 531 (902)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 451-676 (766-1149)
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
Bag In Bag Out N/A
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 1768
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) N/A
Heat Rejected Vented (BTU/Hour) 198
Other Built-in Exhaust Option(s) N/A
Plant Duct Static Pressure Inches (mm) 0.05-0.1"/1.27-2.54mm H2O
Australian Test Method N/A
Performance Standard NSF-ANSI-49
Safety Certification UL, UL-C
Air Cleanliness (ISO 14644) ISO-Class-5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor SingleAirflowSensor
Control System FlowGard
Est. Shipping Weight lbs (kg) 620 (281)
Net Weight lbs (kg) 570 (258)
Blower Contact Wires N/A
Closure Panels N/A
Cord Pass Through Standard Right
Double Exhaust HEPA Filter N/A
Gas Supply Interlock with Blower N/A
Glass Sidewalls N/A
IV Bar with 6 Hooks Optional
Magnifying Glass in Window N/A
Motorized Base Stand Optional as Separate Accessory
Motorized Window N/A
Other Built-in Supply Filter Option(s) N/A
Outlet(s) Standard, two backwall
Plumbing N/A
Remote Service Valves N/A
Seismic Brackets or Studs N/A
Service Couplings (3/8-inch NPT) Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Two Each Side Wall Optional
Service Valves (3/8-inch NPT) One Valve on Right Side Wall is Standard, Maximum of Two Each Side Wall Optional
Side Panels N/A
Smooth Interior N/A
Ultraviolet (UV) Light Optional
Window Edge Protector N/A
Access Opening Glass Type Safety Glass
Armrest Plastic
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Casters N/A
Decontamination Seal-able Window N/A
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 11 1/2-inch (292 mm) 99.995% Efficiency @ MPPS
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Seam Welded Stainless Steel Side and Back Wall Construction
Motor(s) 1 HP DC ECM
Plenum Type HEPEX
Pre-filter N/A
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.995% Efficiency @ MPPS
Viewing Window Inches (mm) 21 (533) open to fully closed
Work Access Opening(s) 10-inch (254 mm)
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 41.3 (1050mm)
Est. Shipping Height Inches (mm) 76.8 (1950mm)
Est. Shipping Width Inches (mm) 74.8 (1900)
Exterior Depth Inches (mm) 32 3/16 (817)
Exterior Depth with Armrest Removed Inches (mm) 31 7/16 (799)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 87 3/8 (2219)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 93 3/8 (2372)
Exterior Width Inches (mm) 53 5/8 (1362)
Nominal Width Feet (Meters) 5 ft. (1.5m)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 57 7/8 (1470)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 25 3/4 (654)
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) N/A
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 58 3/8 (1483)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 4.5
Blower/Lights Amps [12-inch (305 mm) Access Opening]
Blower/Lights Amps [14-inch (356mm) Access Opening]
Blower/Lights Amps [8-inch (203 mm) Access Opening]
Electrical Configuration 115V60Hz
Junction Box N/A
Outlet Amps 3
Power Cord 12 GA - 3 Wire, 20A
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 16
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 Inquire
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 531 (902)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 451-676 (766-1149)
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
Bag In Bag Out N/A
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 1768
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) N/A
Heat Rejected Vented (BTU/Hour) 198
Other Built-in Exhaust Option(s) N/A
Plant Duct Static Pressure Inches (mm) 0.05-0.1"/1.27-2.54mm H2O
Australian Test Method N/A
Performance Standard NSF-ANSI-49
Safety Certification UL, UL-C
Air Cleanliness (ISO 14644) ISO-Class-5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor SingleAirflowSensor
Control System FlowGard
Est. Shipping Weight lbs (kg) 620 (281)
Net Weight lbs (kg) 570 (258)
Blower Contact Wires N/A
Closure Panels N/A
Cord Pass Through Standard Right
Double Exhaust HEPA Filter Optional
Gas Supply Interlock with Blower N/A
Glass Sidewalls N/A
IV Bar with 6 Hooks Optional
Magnifying Glass in Window N/A
Motorized Base Stand Optional as Separate Accessory
Motorized Window N/A
Other Built-in Supply Filter Option(s) N/A
Outlet(s) Standard, two backwall
Plumbing N/A
Remote Service Valves N/A
Seismic Brackets or Studs N/A
Service Couplings (3/8-inch NPT) Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Two Each Side Wall Optional
Service Valves (3/8-inch NPT) One Valve on Right Side Wall is Standard, Maximum of Two Each Side Wall Optional
Side Panels N/A
Smooth Interior N/A
Ultraviolet (UV) Light Optional
Window Edge Protector N/A
Access Opening Glass Type Safety Glass
Armrest Plastic
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Casters N/A
Decontamination Seal-able Window N/A
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 11 1/2-inch (292 mm) 99.995% Efficiency @ MPPS
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Seam Welded Stainless Steel Side and Back Wall Construction
Motor(s) 1 HP DC ECM
Plenum Type HEPEX
Pre-filter N/A
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.995% Efficiency @ MPPS
Viewing Window Inches (mm) 21 (533) open to fully closed
Work Access Opening(s) 10-inch (254 mm)
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 41.3 (1050mm)
Est. Shipping Height Inches (mm) 76.8 (1950mm)
Est. Shipping Width Inches (mm) 74.8 (1900)
Exterior Depth Inches (mm) 32 3/16 (817)
Exterior Depth with Armrest Removed Inches (mm) 31 7/16 (799)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 87 3/8 (2219)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 93 3/8 (2372)
Exterior Width Inches (mm) 65 5/8 (1669)
Nominal Width Feet (Meters) 5 ft. (1.5m)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 57 7/8 (1470)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 25 3/4 (654)
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) N/A
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 58 3/8 (1483)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 4.5
Blower/Lights Amps [12-inch (305 mm) Access Opening]
Blower/Lights Amps [14-inch (356mm) Access Opening]
Blower/Lights Amps [8-inch (203 mm) Access Opening]
Electrical Configuration 230V5060Hz
Junction Box N/A
Outlet Amps 3
Power Cord Single 12-foot (3.7m) 14 GA - 3 Wire, 15A
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 11
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 ≤ 58 dba
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 531 (902)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 451-676 (766-1149)
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
Bag In Bag Out N/A
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 1768
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) N/A
Heat Rejected Vented (BTU/Hour) 198
Other Built-in Exhaust Option(s) N/A
Plant Duct Static Pressure Inches (mm) 0.05-0.1" (1.27-2.54)
Australian Test Method Optional
Performance Standard NSF-ANSI-49, EN-12469
Safety Certification UL, UL-C
Air Cleanliness (ISO 14644) ISO-Class-5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor SingleAirflowSensor
Control System FlowGard
Est. Shipping Weight lbs (kg) 620 (281)
Net Weight lbs (kg) 570 (258)
Blower Contact Wires Optional
Closure Panels Optional Rear Closure Panels for Seismic Brackets
Cord Pass Through Standard Right
Double Exhaust HEPA Filter N/A
Gas Supply Interlock with Blower N/A
Glass Sidewalls Optional with 8 or 10 inch (203 or 254mm) Work Access Openings
IV Bar with 6 Hooks Optional
Magnifying Glass in Window N/A
Motorized Base Stand Optional as Separate Accessory
Motorized Window N/A
Other Built-in Supply Filter Option(s) N/A
Outlet(s) Standard, two backwall
Plumbing Optional 3/8" Soft Copper, 3/8" Black Pipe (Gas Only), or 1/2" Rigid Copper
Remote Service Valves N/A
Seismic Brackets or Studs Optional Rear or Floor Mount Seismic Brackets
Service Couplings (3/8-inch NPT) Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Three Each Side Wall Optional
Service Valves (3/8-inch NPT) One Valve on Right Side Wall is Standard, Maximum of Three Each Side Wall Optional
Side Panels Optional with Plumbing out Bottom, Top or Back
Smooth Interior Optional
Ultraviolet (UV) Light Optional
Window Edge Protector Optional
Access Opening Glass Type Tempered
Armrest Standard Plastic with Optional Stainless Steel
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Casters N/A
Decontamination Seal-able Window N/A
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 11 1/2-inch (292 mm) 99.99% Efficiency on 0.3 microns
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Single Piece Stainless Steel Side and Back Wall Construction
Motor(s) 1 HP DC ECM
Plenum Type HEPEX
Pre-filter N/A
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.99% Efficiency on 0.3 microns
Viewing Window Inches (mm) 21 (533) open to fully closed
Work Access Opening(s) 8, 10, 12-inch (203, 254, 305 mm)
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 43 (1092)
Est. Shipping Height Inches (mm) 70 (1778)
Est. Shipping Width Inches (mm) 82 (2083)
Exterior Depth Inches (mm) 32 1/8 (817)
Exterior Depth with Armrest Removed Inches (mm) 31 7/16 (799)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 87.375 (2219)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 93.375 (2371)
Exterior Width Inches (mm) 77 5/8 (1972)
Nominal Width Feet (Meters) 6 ft. (1.8m)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 69 7/8 (1775)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 25 3/4 (654)
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) Inquire
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) Inquire
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 70 3/8 (1788)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 4.8
Blower/Lights Amps [12-inch (305 mm) Access Opening] 5.2
Blower/Lights Amps [14-inch (356mm) Access Opening]
Blower/Lights Amps [8-inch (203 mm) Access Opening] 4.5
Electrical Configuration 115V60Hz
Junction Box Optional
Outlet Amps 3
Power Cord 12 gauge - 3 Wire, 20A
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 16
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 ≤ 60 dba
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 634 (1077)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 538-763 (915-1297)
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 763 (1251)
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 634-865 (1088-1470)
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 532 (904)
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 436-661 (741-1124)
Bag In Bag Out N/A
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 1884
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) 2041
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) 1768
Heat Rejected Vented (BTU/Hour) 198
Other Built-in Exhaust Option(s) N/A
Plant Duct Static Pressure Inches (mm) 0.05-0.1"/1.27-2.54mm H2O
Australian Test Method N/A
Performance Standard NSF-ANSI-49
Safety Certification UL, UL-C
Air Cleanliness (ISO 14644) ISO-Class-5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor SingleAirflowSensor
Control System FlowGard
Est. Shipping Weight lbs (kg) 690 lbs. / 313 kg
Net Weight lbs (kg) 640 lbs. / 290 kg.
Blower Contact Wires Optional
Closure Panels Optional Rear Closure Panels for Seismic Brackets
Cord Pass Through Standard Right
Double Exhaust HEPA Filter Optional
Gas Supply Interlock with Blower N/A
Glass Sidewalls Optional
IV Bar with 6 Hooks Optional
Magnifying Glass in Window N/A
Motorized Base Stand Optional as Separate Accessory
Motorized Window N/A
Other Built-in Supply Filter Option(s) N/A
Outlet(s) Standard, two backwall
Plumbing Optional 3/8" Soft Copper, 3/8" Black Pipe (Gas Only), or 1/2" Rigid Copper
Remote Service Valves N/A
Seismic Brackets or Studs Optional Rear or Floor Mount Seismic Brackets
Service Couplings (3/8-inch NPT) Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Three Each Side Wall Optional
Service Valves (3/8-inch NPT) One Valve on Right Side Wall is Standard, Maximum of Three Each Side Wall Optional
Side Panels Optional with Plumbing out Bottom, Top or Back
Smooth Interior N/A
Ultraviolet (UV) Light Optional
Window Edge Protector Optional
Access Opening Glass Type Safety Glass
Armrest Standard Plastic with Optional Stainless Steel
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Casters N/A
Decontamination Seal-able Window N/A
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 11 1/2-inch (292 mm) 99.995% Efficiency @ MPPS
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Single Piece Stainless Steel Side and Back Wall Construction
Motor(s) 1 HP DC ECM
Plenum Type HEPEX
Pre-filter N/A
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.995% Efficiency @ MPPS
Viewing Window Inches (mm) 21 (533) open to fully closed
Work Access Opening(s) 10-inch (254 mm)
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 43 (1092)
Est. Shipping Height Inches (mm) 70 (1778)
Est. Shipping Width Inches (mm) 82 (2083)
Exterior Depth Inches (mm) 32 1/8 (817)
Exterior Depth with Armrest Removed Inches (mm) 31 7/16 (799)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 88 3/8 (2245)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 94 3/8 (2397)
Exterior Width Inches (mm) 77 5/8 (1972)
Nominal Width Feet (Meters) 6 ft. (1.8m)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 69 7/8 (1775)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 25 3/4 (654)
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) N/A
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 70 3/8 (1788)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 4.8
Blower/Lights Amps [12-inch (305 mm) Access Opening]
Blower/Lights Amps [14-inch (356mm) Access Opening]
Blower/Lights Amps [8-inch (203 mm) Access Opening]
Electrical Configuration 230V5060Hz
Junction Box Optional
Outlet Amps 3
Power Cord 14 gauge - 3 Wire, 15A
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 11
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 ≤ 60 dba
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 634 (1077)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 538-763 (915-1297)
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
Bag In Bag Out N/A
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 1884
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) N/A
Heat Rejected Vented (BTU/Hour) 198
Other Built-in Exhaust Option(s) N/A
Plant Duct Static Pressure Inches (mm) 0.05-0.1"/1.27-2.54mm H2O
Australian Test Method Optional
Performance Standard NSF-ANSI-49, EN-12469
Safety Certification
Air Cleanliness (ISO 14644) ISO-Class-5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor SingleAirflowSensor
Control System FlowGard
Est. Shipping Weight lbs (kg) 690 lbs. / 313 kg
Net Weight lbs (kg) 640 lbs. / 290 kg.
Blower Contact Wires N/A
Closure Panels N/A
Cord Pass Through Standard Right
Double Exhaust HEPA Filter N/A
Gas Supply Interlock with Blower N/A
Glass Sidewalls N/A
IV Bar with 6 Hooks Optional
Magnifying Glass in Window N/A
Motorized Base Stand Optional as Separate Accessory
Motorized Window N/A
Other Built-in Supply Filter Option(s) N/A
Outlet(s) Standard, two backwall
Plumbing N/A
Remote Service Valves N/A
Seismic Brackets or Studs N/A
Service Couplings (3/8-inch NPT) Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Two Each Side Wall Optional
Service Valves (3/8-inch NPT) One Valve on Right Side Wall is Standard, Maximum of Two Each Side Wall Optional
Side Panels N/A
Smooth Interior N/A
Ultraviolet (UV) Light Optional
Window Edge Protector N/A
Access Opening Glass Type Safety Glass
Armrest Plastic
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Casters N/A
Decontamination Seal-able Window N/A
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 11 1/2-inch (292 mm) 99.995% Efficiency @ MPPS
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Seam Welded Stainless Steel Side and Back Wall Construction
Motor(s) 1 HP DC ECM
Plenum Type HEPEX
Pre-filter N/A
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.995% Efficiency @ MPPS
Viewing Window Inches (mm) 21 (533) open to fully closed
Work Access Opening(s) 10-inch (254 mm)
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 41.3 (1050mm)
Est. Shipping Height Inches (mm) 76.8 (1950mm)
Est. Shipping Width Inches (mm) 80.3 (2040)
Exterior Depth Inches (mm) 32 3/16 (817)
Exterior Depth with Armrest Removed Inches (mm) 31 7/16 (799)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 87 3/8 (2219)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 93 3/8 (2372)
Exterior Width Inches (mm) 77 5/8 (1972)
Nominal Width Feet (Meters) 6 ft. (1.8m)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 69 7/8 (1775)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 25 3/4 (654)
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) N/A
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 70 3/8 (1788)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 4.8
Blower/Lights Amps [12-inch (305 mm) Access Opening]
Blower/Lights Amps [14-inch (356mm) Access Opening]
Blower/Lights Amps [8-inch (203 mm) Access Opening]
Electrical Configuration 100V5060Hz
Junction Box N/A
Outlet Amps 2
Power Cord 12 GA - 3 Wire, 20A
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 13
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 Inquire
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 634 (1077)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 538-763 (915-1297)
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
Bag In Bag Out N/A
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 1884
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) N/A
Heat Rejected Vented (BTU/Hour) 198
Other Built-in Exhaust Option(s) N/A
Plant Duct Static Pressure Inches (mm) 0.05-0.1"/1.27-2.54mm H2O
Australian Test Method N/A
Performance Standard NSF-ANSI-49
Safety Certification UL, UL-C
Air Cleanliness (ISO 14644) ISO-Class-5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor SingleAirflowSensor
Control System FlowGard
Est. Shipping Weight lbs (kg) 690 (313)
Net Weight lbs (kg) 640 (290)
Blower Contact Wires N/A
Closure Panels N/A
Cord Pass Through Standard Right
Double Exhaust HEPA Filter N/A
Gas Supply Interlock with Blower N/A
Glass Sidewalls N/A
IV Bar with 6 Hooks Optional
Magnifying Glass in Window N/A
Motorized Base Stand Optional as Separate Accessory
Motorized Window N/A
Other Built-in Supply Filter Option(s) N/A
Outlet(s) Standard, two backwall
Plumbing N/A
Remote Service Valves N/A
Seismic Brackets or Studs N/A
Service Couplings (3/8-inch NPT) Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Two Each Side Wall Optional
Service Valves (3/8-inch NPT) One Valve on Right Side Wall is Standard, Maximum of Two Each Side Wall Optional
Side Panels N/A
Smooth Interior N/A
Ultraviolet (UV) Light Optional
Window Edge Protector N/A
Access Opening Glass Type Safety Glass
Armrest Plastic
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Casters N/A
Decontamination Seal-able Window N/A
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 11 1/2-inch (292 mm) 99.995% Efficiency @ MPPS
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Seam Welded Stainless Steel Side and Back Wall Construction
Motor(s) 1 HP DC ECM
Plenum Type HEPEX
Pre-filter N/A
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.995% Efficiency @ MPPS
Viewing Window Inches (mm) 21 (533) open to fully closed
Work Access Opening(s) 10-inch (254 mm)
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 41.3 (1050mm)
Est. Shipping Height Inches (mm) 76.8 (1950mm)
Est. Shipping Width Inches (mm) 80.3 (2040)
Exterior Depth Inches (mm) 32 3/16 (817)
Exterior Depth with Armrest Removed Inches (mm) 31 7/16 (799)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 87 3/8 (2219)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 93 3/8 (2372)
Exterior Width Inches (mm) 77 5/8 (1972)
Nominal Width Feet (Meters) 6 ft. (1.8m)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 69 7/8 (1775)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 25 3/4 (654)
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) N/A
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 70 3/8 (1788)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 4.8
Blower/Lights Amps [12-inch (305 mm) Access Opening]
Blower/Lights Amps [14-inch (356mm) Access Opening]
Blower/Lights Amps [8-inch (203 mm) Access Opening]
Electrical Configuration 100V5060Hz
Junction Box N/A
Outlet Amps 3
Power Cord 12 GA - 3 Wire, 20A
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 16
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 Inquire
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 634 (1077)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 538-763 (915-1297)
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
Bag In Bag Out N/A
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 1884
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) N/A
Heat Rejected Vented (BTU/Hour) 198
Other Built-in Exhaust Option(s) N/A
Plant Duct Static Pressure Inches (mm) 0.05-0.1"/1.27-2.54mm H2O
Australian Test Method N/A
Performance Standard NSF-ANSI-49
Safety Certification UL, UL-C
Air Cleanliness (ISO 14644) ISO-Class-5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor SingleAirflowSensor
Control System FlowGard
Est. Shipping Weight lbs (kg) 690 (313)
Net Weight lbs (kg) 640 (290)
Blower Contact Wires N/A
Closure Panels N/A
Cord Pass Through Standard Right
Double Exhaust HEPA Filter Optional
Gas Supply Interlock with Blower N/A
Glass Sidewalls N/A
IV Bar with 6 Hooks Optional
Magnifying Glass in Window N/A
Motorized Base Stand Optional as Separate Accessory
Motorized Window N/A
Other Built-in Supply Filter Option(s) N/A
Outlet(s) Standard, two backwall
Plumbing N/A
Remote Service Valves N/A
Seismic Brackets or Studs N/A
Service Couplings (3/8-inch NPT) Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Two Each Side Wall Optional
Service Valves (3/8-inch NPT) One Valve on Right Side Wall is Standard, Maximum of Two Each Side Wall Optional
Side Panels N/A
Smooth Interior N/A
Ultraviolet (UV) Light Optional
Window Edge Protector N/A
Access Opening Glass Type Safety Glass
Armrest Plastic
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Casters N/A
Decontamination Seal-able Window N/A
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 11 1/2-inch (292 mm) 99.995% Efficiency @ MPPS
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Seam Welded Stainless Steel Side and Back Wall Construction
Motor(s) 1 HP DC ECM
Plenum Type HEPEX
Pre-filter N/A
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.995% Efficiency @ MPPS
Viewing Window Inches (mm) 21 (533) open to fully closed
Work Access Opening(s) 10-inch (254 mm)
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 41.3 (1050mm)
Est. Shipping Height Inches (mm) 76.8 (1950mm)
Est. Shipping Width Inches (mm) 80.3 (2040)
Exterior Depth Inches (mm) 32 3/16 (817)
Exterior Depth with Armrest Removed Inches (mm) 31 7/16 (799)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 87 3/8 (2219)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 93 3/8 (2372)
Exterior Width Inches (mm) 77 5/8 (1972)
Nominal Width Feet (Meters) 6 ft. (1.8m)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 69 7/8 (1775)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 25 3/4 (654)
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) N/A
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 70 3/8 (1788)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 4.8
Blower/Lights Amps [12-inch (305 mm) Access Opening]
Blower/Lights Amps [14-inch (356mm) Access Opening]
Blower/Lights Amps [8-inch (203 mm) Access Opening]
Electrical Configuration 230V5060Hz
Junction Box N/A
Outlet Amps 3
Power Cord Single 12-foot (3.7m) 14 GA - 3 Wire, 15A
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 11
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 ≤ 60 dba
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 634 (1077)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 538-763 (915-1297)
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
Bag In Bag Out N/A
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 1884
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) N/A
Heat Rejected Vented (BTU/Hour) 198
Other Built-in Exhaust Option(s) N/A
Plant Duct Static Pressure Inches (mm) 0.05-0.1" (1.27-2.54)
Australian Test Method Optional
Performance Standard NSF-ANSI-49, EN-12469
Safety Certification UL, UL-C
Air Cleanliness (ISO 14644) ISO-Class-5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor SingleAirflowSensor
Control System FlowGard
Est. Shipping Weight lbs (kg) 690 (313)
Net Weight lbs (kg) 640 (290)

Review

Resources

Options

  • 3-foot Width (0.91 meters)
  • 4-foot Width (1.22 meters)
  • 5-foot Width (1.52 meters)
  • 6-foot Width (1.83 meters)
  • Stainless Steel Coved Interior, Cord Pass Through Right Sidewall, 2 Left Couplings, 1 Right Coupling and 1 Right Valve
  • Stainless Steel Smooth Interior, Outlets Front Fairing, Cord Pass Through Right Sidewall
  • Glass Side Walls, Stainless Steel Coved Interior, 2 Left Couplings, 1 Right Coupling and 1 Right Valve
  • 8-inch (203 mm) Access Opening, Manual Adjustable, Tempered Glass
  • 10-inch (254 mm) Access Opening, Manual Adjustable, Tempered Glass
  • 10-inch (254 mm) Access Opening, Manual Adjustable, Safety Plate Glass
  • 12-inch (305 mm) Access Opening, Manual Adjustable, Tempered Glass
  • 115V, 60Hz, 20 Amp, NEMA 5-20P
  • 230V, 50/60 Hz, 15 Amp, Type F Plug
  • 100V, 50/60Hz, 15 Amp, Plug Type B NEMA 5-15P
  • Outlets, GFI, Qty 2 Duplex Outlets, NEMA 5-15R, 3 Amp Max, 115V
  • Outlets, Qty 2 Duplex Outlets, NEMA 5-15R, 15 Amp Max, Dedicated NEMA 5-15P Power Cord, 115V
  • Outlets, GFI, Qty 2 Duplex Outlets, NEMA 5-15R, 15 Amp Max, Dedicated NEMA 5-15P Power Cord, 115V
  • Outlets, Qty 2 Duplex Outlets, NEMA 5-20R, 20 Amp Max, Dedicated NEMA 5-20P Power Cord, 115V
  • Outlets, GFI, Qty 2 Duplex Outlets, NEMA 5-20R, 20 Amp Max, Dedicated NEMA 5-20P Power Cord, 115V
  • Outlets, GFI, Qty 2 Duplex Outlets, NEMA 5-15R, 5 Amp Max, Removes Accessory Outlet, 115V
  • Outlets, Qty 2, Socket Type B, 3 Amp Max, 230V
  • Outlets, Qty 2, Socket Type D, 3 Amp Max, 230V
  • Outlets, Qty 2, Socket Type E, 3 Amp Max, 230V
  • Outlets, Qty 2, Socket Type F, 3 Amp Max, 230V
  • Outlets, Qty 2, Socket Type G, 3 Amp Max, 230V
  • Outlets, Qty 2, Socket Type H, 3 Amp Max, 230V
  • Outlets, Qty 2, Socket Type I, 3 Amp Max, 230V
  • Outlets, Qty 2, Socket Type J, 3 Amp Max, 230V
  • Outlets, Qty 2, Socket Type K, 3 Amp Max, 230V
  • Outlets, Qty 2, Socket Type M, 3 Amp Max, 230V
  • No UV Light, Field Retrofittable
  • No UV Light, NON-Field Retrofittable
  • UV Light Backwall
  • 3-inch (76 mm) Supply, 12-inch (305 mm) Exhaust Metal Frame Separatorless 99.99% @ 0.3 Micron HEPA Filters with Permanent Plenum
  • Stainless Steel Armrest
  • IV Bar with 6 hooks and 3 height locations
  • Stainless Steel Window Edge Protector
  • Blower Contact Wires for Biosafety Cabinet
  • Cord Pass-Thru Left Sidewall, NSF Approved
  • Power Cord with Twist Lock Plug
  • Cable Management Brackets
  • Left Top Service Valve
  • Left Middle Service Valve
  • Left Bottom Service Valve
  • Right Top Service Valve
  • Right Middle Service Valve
  • Right Bottom Service Coupling, Replaces Right Bottom Service Valve
  • Left Top Service Coupling
  • Right Top Service Coupling
  • Side Panels without Plumbing
  • Side Panels with Plumbing Out Bottom
  • Side Panels with Plumbing Out Top
  • Side Panels with Plumbing Out Back
  • Plumbing Line - Soft Copper 3/8
  • Plumbing Line - Black Pipe 3/8
  • Plumbing Line - Rigid Copper 1/2
  • Stainless Steel Flexible Pipe 96-inches (2439 mm)
  • CSST Yellow Flexible Pipe 96-inches (2439 mm)
  • Telescoping Base Stand, Leg Levelers
  • Telescoping Base Stand, Casters
  • Motorized Base Stand, Leg Levelers
  • Motorized Base Stand, Casters
  • Telescoping Base Stand with Storage Cabinet
  • Telescoping Base Stand, Seismic/OPM, Leg Levelers Shipped Factory Assembled
  • Motorized Base Stand, Seismic Floor Mount, Leg Levelers
  • Base Stand Shelf 8-inches (203mm)
  • Base Stand Shelf 12-inches (305mm)
  • Ergotron Workstation for Telescoping Base Stand
  • Ergotron Workstation for Motorized Base Stand
  • Ergotron Laptop Arm for Telescoping Biosafety Cabinet Base Stands
  • Ergotron Laptop Arm for Automatic Adjustable Biosafety Cabinet Base Stands
  • Seismic Brackets, Rear Mount
  • Seismic Brackets, Rear Mount
  • Seismic Brackets, Floor Mount for Telescoping Base Stand
  • Rear Closure Panel
  • Variable Range Low Flow Exhaust Canopy with Monitor
  • Fixed Range Transition for 4-foot (1.2 m) Width, 10-inch (254 mm) Collar Diameter
  • 25% Fill Activated Charcoal Filter Exhaust Transition for 4-foot (1.2 m) Width
  • 25% Fill Purafill Filter Exhaust Transition for 4-foot (1.2 m) Width
  • Low Airflow Alarm 115V
  • Digital Manometer Monitor 115V
  • Silicone Connection Sleeve Kit
  • Flex Duct, 10-inch (254 mm) Diameter, 8-feet (2.4 m), Qty 2 Stainless Steel Band Clamps
  • 10-inch (254 mm) Diameter Manual Air Tight Stainless Steel Butterfly Damper
  • Flex Duct, 8-inch (203 mm) Diameter, 8-feet (2.4 m), Qty 2 Stainless Steel Band Clamps
  • 8-inch (203 mm) Diameter Manual Air Tight Stainless Steel Butterfly Damper
  • 8-inch (203 mm) to 10-inch (254 mm) Round to Round Transition
  • Adjustable Footrest
  • Forearm Pad for Armrest (Disposable Pkg of 10)
  • Stainless Steel Table, Rotating, 12-inch (305 mm) Diameter
  • Silicone Pad Elbow Rest 3 x 5-inches (76 x 127 mm)
  • Silicone Pad Elbow Rest 3 x 10-inches (76 x 254 mm)
  • Ergonomic Accessory Kit

Request Your Quote for a NU-543