In-VitroCell NU-8600 Water Jacket CO2 Incubator

The NU-8600 Water Jacket CO2 incubator combines a traditional water-jacketed design's temperature uniformity and stability with a modern touch screen's effortless control and performance monitoring.

Overview

The In-VitroCell NU-8600 Water Jacket CO2 incubator offers modern control and monitoring of temperature and CO2 levels inside a traditional water jacket design for applications prioritizing stability and security. Beyond using an infrared sensor for precise control of CO2 and a 68-liter water jacket for reliable and uniform internal temperature. The air pump is located outside the 160-liter stainless steel chamber that constantly draws air through a HEPA filter and cycles it back to the growth chamber. This closed-loop HEPA filtration system helps to create ISO Class 5 quality air at positive pressure to minimize contamination. A touch screen makes it easy to enter set points and view or download historical performance. In addition, this moderately sized incubator can be stacked to efficiently use the valuable space in your laboratory.

Streamline Your Lab with Intuitive Control

The NuTouch control system blends modern convenience with scientific precision, offering an intuitive touchscreen interface for effortless operation. Easily adjust settings, review your chamber's historical data, and calibrate your system, all at your fingertips – a perfect fusion of ease and functionality for optimizing cell growth environments.

Uniform Temperature Control 

The In-VitroCell Water Jacket CO2 Incubators create the ideal environment for cell growth with their advanced 18-gallon water jacket system. This feature ensures a uniform temperature distribution within the growth chamber, maintaining accuracy within ±0.2°C. Enhanced by R5 insulation, the outer chamber effectively minimizes heat loss. Moreover, the incubator's door and perimeter heaters are microprocessor-controlled, adapting seamlessly to the ambient room temperature. For additional precision, these heaters can be manually adjusted by ±20 percent to minimize condensation, ensuring a stable and optimal environment for cell cultures.

Advanced HEPA Filtration for Optimal Cell Culture Protection

Experience enhanced cell culture growth with In-VitroCell's advanced HEPA filtration system for Constant Contamination Control. Our unique system continually samples and filters the chamber air, routing it through a dedicated HEPA filter outside the main chamber. This process maintains an ISO Class 5 clean air environment and establishes a slight positive pressure to safeguard against further contamination. With In-VitroCell, your sensitive cell cultures are nurtured in a meticulously controlled, contamination-resistant habitat, ensuring their integrity and vitality.

Sleek Design for Enhanced Cleanliness

Discover the ease of maintaining a pristine cell culture environment with NuAire CO2 Incubators. Our thoughtfully designed coved interior corners eliminate hard-to-reach spots, ensuring easy cleaning and reducing the risk of bacterial growth. The seamless, crevice-free interior simplifies the cleaning process and significantly diminishes potential hiding places for contaminants. With NuAire, you can trust an incubator that combines scientific precision with practical, user-friendly maintenance.

Specifications

In-VitroCell NU-8600 Water Jacket CO2 Incubator
CO2 Accuracy ± 0.1%
CO2 Control Logic Fixed Algorithm/Manual, Environmental Adaptable
CO2 Display Resolution 0.1%
CO2 Range 0.1 to 20%, 5% Default Set Point
CO2 Recovery Up to 5% ± 0.2% / -0.5 in 5 minutes Average
CO2 Sensor Type Infrared (NDIR)
Segmented Doors Optional Set of 4 Inner Doors
Access Port Location Right Side
Chamber Air Filter 99.97% Efficiency @ ≥ 0.3 Micron Capsule Filter Located in Sensor Bay
Exterior Door Seal Magnetic Outer Door Gasket
Exterior Material 16 Gauge Steel with Textured Polyurethane Finish
In-line Gas Filters 99.97% Efficiency @ ≥ 0.3 Micron Disk Filters for Gas & Air Supplies, Disk Filter for CO2 Sensor
Inner Doors One Standard, Sectional optional
Insulation Insulation with R5.0 Rating
Interior Door Seal Silicone Rubber Gasket
Interior Material Polished Type 304L 16 Gauge Stainless Steel
Sample Port Location Inner Glass Door
Shelf Capacity lbs (kg) 25 lbs per Shelf / 125 lbs per Incubator
Shelf Material Stainless Steel or Copper Alloy
Shelves 4 Shelves Supplied, 16 Shelves Maximum Capacity
Data Output Features RS-485, USB, 4-20mA
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 33 (838)
Est. Shipping Height Inches (mm) 49 (1245)
Est. Shipping Width Inches (mm) 31 (787)
Exterior Depth Inches (mm) 27 (685)
Exterior Height Inches (mm) 37.75 (958)
Exterior Width Inches (mm) 25.625 (649)
Footprint Depth inches (mm) 17.5 (445)
Footprint Width inches (mm) 22 (557)
Interior Depth Inches (mm) 20.625 (524)
Interior Height Inches (mm) 24 (611)
Interior Volume Cubic Feet (Liters) 5.65 (160)
Interior Width Inches (mm) 20.375 (518)
Shelf Depth Inches (mm) 18 3/4 (476)
Shelf Width Inches (mm) 18 (457)
Water Pan Depth 1.5 (38)
Water Pan Length Inches (mm) 12 (305)
Water Pan Width 10 (254)
Electrical Configuration 115V 60Hz
Power Cord Length Foot (Meter) 8 (2.5)
Safety Certification UL, UL-C, UK CA
Decontamination Cycle Not available
RH Accuracy Not available
RH Control Method Water Pan
RH Water Pan Capacity 2L (Recommended Fill 1.5L)
Chamber Air Circulation Method Air Pump
Chamber Jacket Technology Water Jacket, 18 Gallon (68-Liter)
Control System NuTouch
Chamber Heater(s) Location Bottom of Chamber
Door and Perimeter Heater Control Logic Base Duty Cycle set to chamber temperature Set-Point, Proportional 0-100% [manually adjustable]
Temperature Accuracy °C ± 0.1%
Temperature Control Water Jacket
Temperature Control Range 5°C above ambient (to a 30°C max ambient) to 55°C
Temperature Display Resolution 0.1°C
Temperature Recovery 0.12°C/min. on Average
Temperature Sensor Type Precision Integrated Circuit
Temperature Set-Point Range 5°C to 55°C (37.0°C Default)
Temperature Uniformity °C ± 0.20°C @ 37°C
Est. Shipping Weight lbs (kg) 370 (168)
Net Weight lbs (kg) 403 (183) includes full water jacket and shelves
CO2 Accuracy ± 0.1%
CO2 Control Logic Fixed Algorithm/Manual, Environmental Adaptable
CO2 Display Resolution 0.1%
CO2 Range 0.1 to 20%, 5% Default Set Point
CO2 Recovery Up to 5% ± 0.2% / -0.5 in 5 minutes Average
CO2 Sensor Type Infrared (NDIR)
Segmented Doors Optional Set of 4 Inner Doors
Access Port Location Right Side
Chamber Air Filter 99.97% Efficiency @ ≥ 0.3 Micron Capsule Filter Located in Sensor Bay
Exterior Door Seal Magnetic Outer Door Gasket
Exterior Material 16 Gauge Steel with Textured Polyurethane Finish
In-line Gas Filters 99.97% Efficiency @ ≥ 0.3 Micron Disk Filters for Gas & Air Supplies, Disk Filter for CO2 Sensor
Inner Doors One Standard, Sectional optional
Insulation Insulation with R5.0 Rating
Interior Door Seal Silicone Rubber Gasket
Interior Material Polished Type 304L 16 Gauge Stainless Steel
Sample Port Location Inner Glass Door
Shelf Capacity lbs (kg) 25 lbs per Shelf / 125 lbs per Incubator
Shelf Material Stainless Steel or Copper Alloy
Shelves 4 Shelves Supplied, 16 Shelves Maximum Capacity
Data Output Features RS-485, USB, 4-20mA
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 33 (838)
Est. Shipping Height Inches (mm) 49 (1245)
Est. Shipping Width Inches (mm) 31 (787)
Exterior Depth Inches (mm) 27 (685)
Exterior Height Inches (mm) 37.75 (958)
Exterior Width Inches (mm) 25.625 (649)
Footprint Depth inches (mm) 17.5 (445)
Footprint Width inches (mm) 22 (557)
Interior Depth Inches (mm) 20.625 (524)
Interior Height Inches (mm) 24 (611)
Interior Volume Cubic Feet (Liters) 5.65 (160)
Interior Width Inches (mm) 20.375 (518)
Shelf Depth Inches (mm) 18 3/4 (476)
Shelf Width Inches (mm) 18 (457)
Water Pan Depth 1.5 (38)
Water Pan Length Inches (mm) 12 (305)
Water Pan Width 10 (254)
Electrical Configuration 230V 50/60Hz
Power Cord Length Foot (Meter) 8 (2.5)
Safety Certification UL, UL-C, UK CA
Decontamination Cycle Not available
RH Accuracy Not available
RH Control Method Water Pan
RH Water Pan Capacity 2L (Recommended Fill 1.5L)
Chamber Air Circulation Method Air Pump
Chamber Jacket Technology Water Jacket, 18 Gallon (68-Liter)
Control System NuTouch
Chamber Heater(s) Location Bottom of Chamber
Door and Perimeter Heater Control Logic Base Duty Cycle set to chamber temperature Set-Point, Proportional 0-100% [manually adjustable]
Temperature Accuracy °C ± 0.1%
Temperature Control Water Jacket
Temperature Control Range 5°C above ambient (to a 30°C max ambient) to 55°C
Temperature Display Resolution 0.1°C
Temperature Recovery 0.12°C/min. on Average
Temperature Sensor Type Precision Integrated Circuit
Temperature Set-Point Range 5°C to 55°C (37.0°C Default)
Temperature Uniformity °C ± 0.20°C @ 37°C
Est. Shipping Weight lbs (kg) 370 (168)
Net Weight lbs (kg) 403 (183) includes full water jacket and shelves

Review

Options

  • 115V, 60Hz, 15 Amp, NEMA 5-15P, Made in USA
  • 230V, 50/60 Hz, 15 Amp, Type F Plug, Made in USA
  • 230V, 50/60 Hz, 15 Amp, Plug Type G, Made in USA
  • Stainless Steel Chamber with Floor Mounted Water Pan
  • Stainless Steel Chamber with Coiling Coil and Floor Mounted Water Pan
  • Stainless Steel Shelves (Qty 4)
  • Heavy Duty Stainless Steel Shelves (Qty 4)
  • Copper Alloy Shelves (Qty 4)
  • Left Side Door Hinge
  • Right Hinged Door Swing
  • Standard Glass Door with Cam Action Lock
  • Sectioned Inner Door with Cam Action Locks (4 Vertical Sections)
  • Factory Stacked CO2 Incubators with Qty 1 Castered Platform, Ships Stacked
  • Stacking Brackets for Water Jacket Models
  • Stacking Rack, Floor Mount
  • Platform with Combination Leg Levelers and Casters
  • Regulator CO2 - Two Stage
  • Tank Switch, External, CO2 or N2
  • Tubing Kit (1)
  • Water Pan, Copper Alloy, Qty 1
  • Water Pan, Stainless Steel, Shelf Mount, Qty 1
  • Water Pan, Copper Alloy, Shelf Mounted Qty 1
  • Water Pan, Stainless Steel, Qty 1
  • CO2 Incubator Copper Alloy Shelf (Qty 1) with Guide Brackets (Qty 2)
  • CO2 Incubator Shelf, Stainless Steel (Qty 1) with Guide Brackets (Qty 2)
  • CO2 Incubator Shelf, Stainless Steel, Heavy Duty (Qty 1) with Guide Brackets (Qty 2)

Request Your Quote for a NU-8600

Please fill out the form below for a lab equipment quote and we'll get to work on getting you what you need. Need to talk with someone right away? Give us a call at 763-553-1270.

Thank you for completing the form.

We will be in touch. If you have any urgent questions, please reach out at 763-553-1270.