In-VitroCell NU-8600 Water Jacket CO2 Incubator
The NU-8600 Water Jacket CO2 incubator combines a traditional water-jacketed design's temperature uniformity and stability with a modern touch screen's effortless control and performance monitoring.
- Overview
- Specifications
- Reviews
- Resources
- Options
Overview
The In-VitroCell NU-8600 Water Jacket CO2 incubator offers modern control and monitoring of temperature and CO2 levels inside a traditional water jacket design for applications prioritizing stability and security. Beyond using an infrared sensor for precise control of CO2 and a 68-liter water jacket for reliable and uniform internal temperature. The air pump is located outside the 160-liter stainless steel chamber that constantly draws air through a HEPA filter and cycles it back to the growth chamber. This closed-loop HEPA filtration system helps to create ISO Class 5 quality air at positive pressure to minimize contamination. A touch screen makes it easy to enter set points and view or download historical performance. In addition, this moderately sized incubator can be stacked to efficiently use the valuable space in your laboratory.
Streamline Your Lab with Intuitive Control
The NuTouch control system blends modern convenience with scientific precision, offering an intuitive touchscreen interface for effortless operation. Easily adjust settings, review your chamber's historical data, and calibrate your system, all at your fingertips – a perfect fusion of ease and functionality for optimizing cell growth environments.
Uniform Temperature Control
The In-VitroCell Water Jacket CO2 Incubators create the ideal environment for cell growth with their advanced 18-gallon water jacket system. This feature ensures a uniform temperature distribution within the growth chamber, maintaining accuracy within ±0.2°C. Enhanced by R5 insulation, the outer chamber effectively minimizes heat loss. Moreover, the incubator's door and perimeter heaters are microprocessor-controlled, adapting seamlessly to the ambient room temperature. For additional precision, these heaters can be manually adjusted by ±20 percent to minimize condensation, ensuring a stable and optimal environment for cell cultures.
Advanced HEPA Filtration for Optimal Cell Culture Protection
Experience enhanced cell culture growth with In-VitroCell's advanced HEPA filtration system for Constant Contamination Control. Our unique system continually samples and filters the chamber air, routing it through a dedicated HEPA filter outside the main chamber. This process maintains an ISO Class 5 clean air environment and establishes a slight positive pressure to safeguard against further contamination. With In-VitroCell, your sensitive cell cultures are nurtured in a meticulously controlled, contamination-resistant habitat, ensuring their integrity and vitality.
Sleek Design for Enhanced Cleanliness
Discover the ease of maintaining a pristine cell culture environment with NuAire CO2 Incubators. Our thoughtfully designed coved interior corners eliminate hard-to-reach spots, ensuring easy cleaning and reducing the risk of bacterial growth. The seamless, crevice-free interior simplifies the cleaning process and significantly diminishes potential hiding places for contaminants. With NuAire, you can trust an incubator that combines scientific precision with practical, user-friendly maintenance.
Specifications
CO2 Accuracy | ± 0.1% |
CO2 Control Logic | Fixed Algorithm/Manual, Environmental Adaptable |
CO2 Display Resolution | 0.1% |
CO2 Range | 0.1 to 20%, 5% Default Set Point |
CO2 Recovery | Up to 5% ± 0.2% / -0.5 in 5 minutes Average |
CO2 Sensor Type | Infrared (NDIR) |
Segmented Doors | Optional Set of 4 Inner Doors |
Access Port Location | Right Side |
Chamber Air Filter | 99.97% Efficiency @ ≥ 0.3 Micron Capsule Filter Located in Sensor Bay |
Exterior Door Seal | Magnetic Outer Door Gasket |
Exterior Material | 16 Gauge Steel with Textured Polyurethane Finish |
In-line Gas Filters | 99.97% Efficiency @ ≥ 0.3 Micron Disk Filters for Gas & Air Supplies, Disk Filter for CO2 Sensor |
Inner Doors | One Standard, Sectional optional |
Insulation | Insulation with R5.0 Rating |
Interior Door Seal | Silicone Rubber Gasket |
Interior Material | Polished Type 304L 16 Gauge Stainless Steel |
Sample Port Location | Inner Glass Door |
Shelf Capacity lbs (kg) | 25 lbs per Shelf / 125 lbs per Incubator |
Shelf Material | Stainless Steel or Copper Alloy |
Shelves | 4 Shelves Supplied, 16 Shelves Maximum Capacity |
Data Output Features | RS-485, USB, 4-20mA |
Remote Alarm Terminals | Standard |
Est. Shipping Depth Inches (mm) | 33 (838) |
Est. Shipping Height Inches (mm) | 49 (1245) |
Est. Shipping Width Inches (mm) | 31 (787) |
Exterior Depth Inches (mm) | 27 (685) |
Exterior Height Inches (mm) | 37.75 (958) |
Exterior Width Inches (mm) | 25.625 (649) |
Footprint Depth inches (mm) | 17.5 (445) |
Footprint Width inches (mm) | 22 (557) |
Interior Depth Inches (mm) | 20.625 (524) |
Interior Height Inches (mm) | 24 (611) |
Interior Volume Cubic Feet (Liters) | 5.65 (160) |
Interior Width Inches (mm) | 20.375 (518) |
Shelf Depth Inches (mm) | 18 3/4 (476) |
Shelf Width Inches (mm) | 18 (457) |
Water Pan Depth | 1.5 (38) |
Water Pan Length Inches (mm) | 12 (305) |
Water Pan Width | 10 (254) |
Electrical Configuration | 115V 60Hz |
Power Cord Length Foot (Meter) | 8 (2.5) |
Safety Certification | UL, UL-C, UK CA |
Decontamination Cycle | Not available |
RH Accuracy | Not available |
RH Control Method | Water Pan |
RH Water Pan Capacity | 2L (Recommended Fill 1.5L) |
Chamber Air Circulation Method | Air Pump |
Chamber Jacket Technology | Water Jacket, 18 Gallon (68-Liter) |
Control System | NuTouch |
Chamber Heater(s) Location | Bottom of Chamber |
Door and Perimeter Heater Control Logic | Base Duty Cycle set to chamber temperature Set-Point, Proportional 0-100% [manually adjustable] |
Temperature Accuracy °C | ± 0.1% |
Temperature Control | Water Jacket |
Temperature Control Range | 5°C above ambient (to a 30°C max ambient) to 55°C |
Temperature Display Resolution | 0.1°C |
Temperature Recovery | 0.12°C/min. on Average |
Temperature Sensor Type | Precision Integrated Circuit |
Temperature Set-Point Range | 5°C to 55°C (37.0°C Default) |
Temperature Uniformity °C | ± 0.20°C @ 37°C |
Est. Shipping Weight lbs (kg) | 370 (168) |
Net Weight lbs (kg) | 403 (183) includes full water jacket and shelves |
CO2 Accuracy | ± 0.1% |
CO2 Control Logic | Fixed Algorithm/Manual, Environmental Adaptable |
CO2 Display Resolution | 0.1% |
CO2 Range | 0.1 to 20%, 5% Default Set Point |
CO2 Recovery | Up to 5% ± 0.2% / -0.5 in 5 minutes Average |
CO2 Sensor Type | Infrared (NDIR) |
Segmented Doors | Optional Set of 4 Inner Doors |
Access Port Location | Right Side |
Chamber Air Filter | 99.97% Efficiency @ ≥ 0.3 Micron Capsule Filter Located in Sensor Bay |
Exterior Door Seal | Magnetic Outer Door Gasket |
Exterior Material | 16 Gauge Steel with Textured Polyurethane Finish |
In-line Gas Filters | 99.97% Efficiency @ ≥ 0.3 Micron Disk Filters for Gas & Air Supplies, Disk Filter for CO2 Sensor |
Inner Doors | One Standard, Sectional optional |
Insulation | Insulation with R5.0 Rating |
Interior Door Seal | Silicone Rubber Gasket |
Interior Material | Polished Type 304L 16 Gauge Stainless Steel |
Sample Port Location | Inner Glass Door |
Shelf Capacity lbs (kg) | 25 lbs per Shelf / 125 lbs per Incubator |
Shelf Material | Stainless Steel or Copper Alloy |
Shelves | 4 Shelves Supplied, 16 Shelves Maximum Capacity |
Data Output Features | RS-485, USB, 4-20mA |
Remote Alarm Terminals | Standard |
Est. Shipping Depth Inches (mm) | 33 (838) |
Est. Shipping Height Inches (mm) | 49 (1245) |
Est. Shipping Width Inches (mm) | 31 (787) |
Exterior Depth Inches (mm) | 27 (685) |
Exterior Height Inches (mm) | 37.75 (958) |
Exterior Width Inches (mm) | 25.625 (649) |
Footprint Depth inches (mm) | 17.5 (445) |
Footprint Width inches (mm) | 22 (557) |
Interior Depth Inches (mm) | 20.625 (524) |
Interior Height Inches (mm) | 24 (611) |
Interior Volume Cubic Feet (Liters) | 5.65 (160) |
Interior Width Inches (mm) | 20.375 (518) |
Shelf Depth Inches (mm) | 18 3/4 (476) |
Shelf Width Inches (mm) | 18 (457) |
Water Pan Depth | 1.5 (38) |
Water Pan Length Inches (mm) | 12 (305) |
Water Pan Width | 10 (254) |
Electrical Configuration | 230V 50/60Hz |
Power Cord Length Foot (Meter) | 8 (2.5) |
Safety Certification | UL, UL-C, UK CA |
Decontamination Cycle | Not available |
RH Accuracy | Not available |
RH Control Method | Water Pan |
RH Water Pan Capacity | 2L (Recommended Fill 1.5L) |
Chamber Air Circulation Method | Air Pump |
Chamber Jacket Technology | Water Jacket, 18 Gallon (68-Liter) |
Control System | NuTouch |
Chamber Heater(s) Location | Bottom of Chamber |
Door and Perimeter Heater Control Logic | Base Duty Cycle set to chamber temperature Set-Point, Proportional 0-100% [manually adjustable] |
Temperature Accuracy °C | ± 0.1% |
Temperature Control | Water Jacket |
Temperature Control Range | 5°C above ambient (to a 30°C max ambient) to 55°C |
Temperature Display Resolution | 0.1°C |
Temperature Recovery | 0.12°C/min. on Average |
Temperature Sensor Type | Precision Integrated Circuit |
Temperature Set-Point Range | 5°C to 55°C (37.0°C Default) |
Temperature Uniformity °C | ± 0.20°C @ 37°C |
Est. Shipping Weight lbs (kg) | 370 (168) |
Net Weight lbs (kg) | 403 (183) includes full water jacket and shelves |
Review
Resources
Brochures
Drawings
Videos
Request Your Quote for a NU-8600
Please fill out the form below for a lab equipment quote and we'll get to work on getting you what you need. Need to talk with someone right away? Give us a call at 763-553-1270.
Thank you for completing the form.
We will be in touch. If you have any urgent questions, please reach out at 763-553-1270.