LabGard ES AIR Limited NU-545 Class II Type A2 Biosafety Cabinet

The NU-545 elevates the LabGard® biosafety cabinet design to the next level by complementing the core features with the most complete airflow monitoring and the most sophisticated user interface available.

Overview

The NU-545 elevates the core LabGard® biological safety cabinet design to meet the needs of the most sophisticated applications by monitoring performance with two airflow sensors, displaying current and historical data on a touch panel interface, and allowing users to schedule automatic operation. Technicians can further document and analyze cabinet performance through downloading historical parameters onto a USB drive or fine tune its functioning with set up options. Meant to serve the most demanding biotechnology customers around the world, the LabGard® features an optional motorized front window and a standard stainless-steel armrest. Built for a global market, models are available that meet NSF/ANSI 49 or EN 12469.

TouchLink Control System

The TouchLink control system calculates inflow velocity based on the data received from the exhaust airflow sensor and displays it alongside the readings from the downflow sensor on the front panel. Touch screen control, historical monitoring, and configurable settings enable users to manage airflow when performance must be demonstrated and recorded.

TouchLink Control System from Biosafety Cabinets

Thermistor Exhaust Sensor

A single dual-thermistor airflow sensor in the exhaust measures airflow to enable the FlowGard to calculate inflow velocity for users desiring the most straightforward measurement of cabinet containment performance.

Airflow sensor used in biosafety cabinets.

Downflow Air Sensor

The downflow sensor measures velocity inside the work zone and passes the data to the TouchLink display to assure users of product protection, a critical aspect in many pharmaceutical and biotechnology applications.

Biosafety Cabinet downflow thermistor airflow sensor.

Performance History

The TouchLink control panel showcases a week's worth of cabinet performance data on-screen, while also facilitating the download of a full month's operational history to a USB. This feature is essential for procedures requiring documented airflow conditions in compliance with Good Manufacturing Practice (GMP) standards.

Biosafety Cabinet historical performance graph on TouchLink Control System

Specifications

LabGard NU-545 Class II, Type A2 Biosafety Cabinet
Cord Pass Through Standard Right
Outlet(s) Standard, two backwall
Plumbing Optional 3/8" Soft Copper, 3/8" Black Pipe (Gas Only), or 1/2" Rigid Copper
Access Opening Glass Type Safety Plate
Armrest Stainless Steel
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Decontamination Seal-able Window Standard
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 11 1/2-inch (292 mm) 99.99% Efficiency @ 0.3 Micron
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Single Piece Stainless Steel Side and Back Wall Construction
Motor(s) 1/2 HP DC ECM
Plenum Type HEPEX
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.99% Efficiency @ 0.3 Micron
Viewing Window Inches (mm) 18 (457) open to fully closed
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232, USB
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 43 (1092)
Est. Shipping Height Inches (mm) 71 (1803)
Est. Shipping Width Inches (mm) 46 (1168)
Exterior Depth Inches (mm) 33 7/8 (861)
Exterior Depth with Armrest Removed Inches (mm) 32 1/4 (819)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 87.375 (2219)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 93.375 (2371)
Exterior Width Inches (mm) 41 5/8 (1057)
Nominal Width Feet (Meters) 3 ft. (0.9m)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 33 7/8 (860)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 26 (660)
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 34 3/8 (873)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 2.3
Blower/Lights Amps [8-inch (203 mm) Access Opening] 2.1
Electrical Configuration 115V 60Hz
Outlet Amps 3
Power Cord 14 GA - 3 Wire, 15A
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 10
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 ≤ 55dba
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 320 (544)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 276-501 (649-851)
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 269 (457)
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 255-450 (383-765)
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 903
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) 826
Heat Rejected Vented (BTU/Hour) 120
Plant Duct Static Pressure Inches (mm) 0.05-0.1"/1.27-2.54mm H2O
Performance Standard NSF/ANSI 49
Safety Certification UL, UL-C
Air Cleanliness (ISO 14644) ISO Class 5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor Dual Airflow Sensor
Control System TouchLink
Est. Shipping Weight lbs (kg) 460 lbs. / 209 kg.
Net Weight lbs (kg) 410 lbs. / 186 kg.
Cord Pass Through Standard Right
Outlet(s) Standard, two backwall
Plumbing Optional 3/8" Soft Copper, 3/8" Black Pipe (Gas Only), or 1/2" Rigid Copper
Access Opening Glass Type Safety Glass
Armrest Stainless Steel
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Decontamination Seal-able Window Standard
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 11 1/2-inch (292 mm) 99.995% Efficiency @ 0.3 Micron
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Single Piece Stainless Steel Side and Back Wall Construction
Motor(s) 1/2 HP DC ECM
Plenum Type HEPEX
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.995% Efficiency @ 0.3 Micron
Viewing Window Inches (mm) 18 (457) open to fully closed
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232, USB
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 43 (1092)
Est. Shipping Height Inches (mm) 71 (1803)
Est. Shipping Width Inches (mm) 46 (1168)
Exterior Depth Inches (mm) 33 7/8 (861)
Exterior Depth with Armrest Removed Inches (mm) 32 1/4 (819)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 88 3/8 (2245)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 94 3/8 (2397)
Exterior Width Inches (mm) 41 5/8 (1057)
Nominal Width Feet (Meters) 3 ft. (0.9m)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 33 7/8 (860)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 26 (660)
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 34 3/8 (873)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 1
Electrical Configuration 230V 50/60Hz
Outlet Amps 3
Power Cord 14 GA - 3 Wire, 15A
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 6
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 ≤ 55dba
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 320 (544)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 276-501 (649-851)
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 903
Heat Rejected Vented (BTU/Hour) 120
Plant Duct Static Pressure Inches (mm) 0.05-0.1"/1.27-2.54mm H2O
Performance Standard NSF/ANSI 49, EN 12469
Safety Certification UL, UL-C
Air Cleanliness (ISO 14644) ISO Class 5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor Dual Airflow Sensor
Control System TouchLink
Est. Shipping Weight lbs (kg) 460 lbs. / 209 kg.
Net Weight lbs (kg) 410 lbs. / 186 kg.
Cord Pass Through Standard Right
Outlet(s) Standard, two backwall
Plumbing Optional 3/8" Soft Copper, 3/8" Black Pipe (Gas Only), or 1/2" Rigid Copper
Access Opening Glass Type Safety Plate
Armrest Stainless Steel
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Decontamination Seal-able Window Standard
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 11 1/2-inch (292 mm) 99.99% Efficiency @ 0.3 Micron
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Single Piece Stainless Steel Side and Back Wall Construction
Motor(s) 3/4 HP DC ECM
Plenum Type HEPEX
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.99% Efficiency @ 0.3 Micron
Viewing Window Inches (mm) 18 (457) open to fully closed
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232, USB
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 43 (1092)
Est. Shipping Height Inches (mm) 71 (1803)
Est. Shipping Width Inches (mm) 59 (1499)
Exterior Depth Inches (mm) 33 7/8 (861)
Exterior Depth with Armrest Removed Inches (mm) 32 1/4 (819)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 87.375 (2219)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 93.375 (2371)
Exterior Width Inches (mm) 53 5/8 (1362)
Nominal Width Feet (Meters) 4 (1.2)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 45 7/8 (1165)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 26 (660)
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 46 3/8 (1178)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 2.9
Blower/Lights Amps [8-inch (203 mm) Access Opening] 2.6
Electrical Configuration 115V 60Hz
Outlet Amps 3
Power Cord 12 gauge - 3 Wire, 20A
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 14
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 ≤ 56 dba
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 426 (724)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 363-588 (617-1000)
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 359 (610)
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 295-520 (502-884)
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 1140
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) 1020
Heat Rejected Vented (BTU/Hour) 157
Plant Duct Static Pressure Inches (mm) 0.05-0.1"/1.27-2.54mm H2O
Performance Standard NSF/ANSI 49
Safety Certification UL, UL-C
Air Cleanliness (ISO 14644) ISO Class 5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor Dual Airflow Sensor
Control System TouchLink
Est. Shipping Weight lbs (kg) 530 lbs. / 240 kg.
Net Weight lbs (kg) 480 lbs. / 218 kg.
Cord Pass Through Standard Right
Outlet(s) Standard, two backwall
Plumbing Optional 3/8" Soft Copper, 3/8" Black Pipe (Gas Only), or 1/2" Rigid Copper
Access Opening Glass Type Safety Glass
Armrest Stainless Steel
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Decontamination Seal-able Window Standard
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 11 1/2-inch (292 mm) 99.995% Efficiency @ 0.3 Micron
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Single Piece Stainless Steel Side and Back Wall Construction
Motor(s) 3/4 HP DC ECM
Plenum Type HEPEX
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.995% Efficiency @ 0.3 Micron
Viewing Window Inches (mm) 18 (457) open to fully closed
Work Access Opening(s) 10-inch (254 mm)
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232, USB
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 43 (1092)
Est. Shipping Height Inches (mm) 71 (1803)
Est. Shipping Width Inches (mm) 59 (1499)
Exterior Depth Inches (mm) 33 7/8 (861)
Exterior Depth with Armrest Removed Inches (mm) 31 7/16 (799)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 88 3/8 (2245)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 94 3/8 (2397)
Exterior Width Inches (mm) 53 5/8 (1362)
Nominal Width Feet (Meters) 4 ft. (1.2m)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 45 7/8 (1165)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 26 (660)
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 46 3/8 (1178)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 2.9
Electrical Configuration 230V 50/60Hz
Outlet Amps 3
Power Cord 14 gauge - 3 Wire, 15A
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 10
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 ≤ 56 dba
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 426 (724)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 363-588 (617-1000)
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 1140
Heat Rejected Vented (BTU/Hour) 157
Plant Duct Static Pressure Inches (mm) 0.05-0.1"/1.27-2.54mm H2O
Performance Standard NSF/ANSI 49, EN 12469
Safety Certification UL, UL-C
Air Cleanliness (ISO 14644) ISO Class 5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor Dual Airflow Sensor
Control System TouchLink
Est. Shipping Weight lbs (kg) 530 lbs. / 240 kg.
Net Weight lbs (kg) 480 lbs. / 218 kg.
Cord Pass Through Standard Right
Outlet(s) Standard, two backwall
Plumbing Optional 3/8" Soft Copper, 3/8" Black Pipe (Gas Only), or 1/2" Rigid Copper
Access Opening Glass Type Safety Plate
Armrest Stainless Steel
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Decontamination Seal-able Window Standard
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 11 1/2-inch (292 mm) 99.99% Efficiency @ 0.3 Micron
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Single Piece Stainless Steel Side and Back Wall Construction
Motor(s) 1 HP DC ECM
Plenum Type HEPEX
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.99% Efficiency @ 0.3 Micron
Viewing Window Inches (mm) 18 (457) open to fully closed
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232, USB
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 43 (1092)
Est. Shipping Height Inches (mm) 71 (1803)
Est. Shipping Width Inches (mm) 70 (1778)
Exterior Depth Inches (mm) 33 7/8 (861)
Exterior Depth with Armrest Removed Inches (mm) 32 1/4 (819)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 87.375 (2219)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 93.375 (2371)
Exterior Width Inches (mm) 65 5/8 (1669)
Nominal Width Feet (Meters) 5 ft. (1.5m)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 57 7/8 (1470)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 26 (660)
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 46 3/8 (1178)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 4.5
Blower/Lights Amps [8-inch (203 mm) Access Opening] 4.1
Electrical Configuration 115V 60Hz
Outlet Amps 3
Power Cord 12 gauge - 3 Wire, 20A
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 16
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 ≤ 58 dba
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 531 (902)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 451-676 (766-1149)
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 445 (756)
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 365-590 (621-1003)
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 1768
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) 1611
Heat Rejected Vented (BTU/Hour) 198
Plant Duct Static Pressure Inches (mm) 0.05-0.1"/1.27-2.54mm H2O
Performance Standard NSF/ANSI 49
Safety Certification UL, UL-C
Air Cleanliness (ISO 14644) ISO Class 5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor Dual Airflow Sensor
Control System TouchLink
Est. Shipping Weight lbs (kg) 620 lbs. / 281 kg.
Net Weight lbs (kg) 570 lbs. / 258 kg.
Cord Pass Through Standard Right
Outlet(s) Standard, two backwall
Plumbing Optional 3/8" Soft Copper, 3/8" Black Pipe (Gas Only), or 1/2" Rigid Copper
Access Opening Glass Type Safety Glass
Armrest Stainless Steel
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Decontamination Seal-able Window Standard
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 11 1/2-inch (292 mm) 99.995% Efficiency @ 0.3 Micron
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Single Piece Stainless Steel Side and Back Wall Construction
Motor(s) 1 HP DC ECM
Plenum Type HEPEX
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.995% Efficiency @ 0.3 Micron
Viewing Window Inches (mm) 18 (457) open to fully closed
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232, USB
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 43 (1092)
Est. Shipping Height Inches (mm) 71 (1803)
Est. Shipping Width Inches (mm) 70 (1778)
Exterior Depth Inches (mm) 33 7/8 (861)
Exterior Depth with Armrest Removed Inches (mm) 32 1/4 (819)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 88 3/8 (2245)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 94 3/8 (2397)
Exterior Width Inches (mm) 65 5/8 (1669)
Nominal Width Feet (Meters) 5 ft. (1.5m)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 57 7/8 (1470)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 26 (660)
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 46 3/8 (1178)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 2
Electrical Configuration 230V 50/60Hz
Outlet Amps 3
Power Cord 14 GA-3 Wire, 15 A
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 11
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 ≤ 58
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 531 (902)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 451-676 (766-1149)
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 1768
Heat Rejected Vented (BTU/Hour) 198
Plant Duct Static Pressure Inches (mm) 0.05-0.1"/1.27-2.54mm H2O
Performance Standard NSF/ANSI 49, EN 12469
Safety Certification UL, UL-C
Air Cleanliness (ISO 14644) ISO Class 5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor Dual Airflow Sensor
Control System TouchLink
Est. Shipping Weight lbs (kg) 620 lbs. / 281 kg.
Net Weight lbs (kg) 570 lbs. / 258 kg.
Cord Pass Through Standard Right
Outlet(s) Standard, two backwall
Plumbing Optional 3/8" Soft Copper, 3/8" Black Pipe (Gas Only), or 1/2" Rigid Copper
Access Opening Glass Type Safety Plate
Armrest Stainless Steel
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Decontamination Seal-able Window Standard
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 11 1/2-inch (292 mm) 99.99% Efficiency @ 0.3 Micron
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Single Piece Stainless Steel Side and Back Wall Construction
Motor(s) 1 HP DC ECM
Plenum Type HEPEX
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.99% Efficiency @ 0.3 Micron
Viewing Window Inches (mm) 18 (457) open to fully closed
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232, USB
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 43 (1092)
Est. Shipping Height Inches (mm) 71 (1803)
Est. Shipping Width Inches (mm) 84 (2134)
Exterior Depth Inches (mm) 33 7/8 (861)
Exterior Depth with Armrest Removed Inches (mm) 32 1/4 (819)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 87.375 (2219)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 93.375 (2371)
Exterior Width Inches (mm) 77 5/8 (1972)
Nominal Width Feet (Meters) 6 ft. (1.8m)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 69 7/8 (1775)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 26 (660)
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 70 3/8 (1788)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 4.8
Blower/Lights Amps [8-inch (203 mm) Access Opening] 4.5
Electrical Configuration 115V 60Hz
Outlet Amps 3
Power Cord 12 GA-3 Wire, 20A
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 16
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 ≤ 60 dba
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 634 (1077)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 538-763 (915-1297)
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 532 (904)
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 436-661 (741-1124)
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 1884
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) 1768
Heat Rejected Vented (BTU/Hour) 198
Plant Duct Static Pressure Inches (mm) 0.05-0.1"/1.27-2.54mm H2O
Performance Standard NSF/ANSI 49
Safety Certification UL, UL-C
Air Cleanliness (ISO 14644) ISO Class 5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor Dual Airflow Sensor
Control System TouchLink
Est. Shipping Weight lbs (kg) 690 lbs. / 313 kg.
Net Weight lbs (kg) 640 lbs. / 290 kg.
Cord Pass Through Standard Right
Outlet(s) Standard, two backwall
Plumbing Optional 3/8" Soft Copper, 3/8" Black Pipe (Gas Only), or 1/2" Rigid Copper
Access Opening Glass Type Safety Glass
Armrest Stainless Steel
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Decontamination Seal-able Window Standard
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 11 1/2-inch (292 mm) 99.995% Efficiency @ 0.3 Micron
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Single Piece Stainless Steel Side and Back Wall Construction
Motor(s) 1 HP DC ECM
Plenum Type HEPEX
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.995% Efficiency @ 0.3 Micron
Viewing Window Inches (mm) 18 (457) open to fully closed
Work Access Opening(s) 10-inch (254 mm)
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232, USB
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 43 (1092)
Est. Shipping Height Inches (mm) 71 (1803)
Est. Shipping Width Inches (mm) 84 (2134)
Exterior Depth Inches (mm) 33 7/8 (861)
Exterior Depth with Armrest Removed Inches (mm) 32 1/4 (819)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 88 3/8 (2245)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 94 3/8 (2397)
Exterior Width Inches (mm) 77 5/8 (1972)
Nominal Width Feet (Meters) 6 ft. (1.8m)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 69 7/8 (1775)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 26 (660)
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 70 3/8 (1788)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 2.2
Electrical Configuration 230V 50/60Hz
Outlet Amps 3
Power Cord 14 GA-3 Wire, 15 A
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 11
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 ≤ 60 dba
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 634 (1077)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 538-763 (915-1297)
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 1884
Heat Rejected Vented (BTU/Hour) 198
Plant Duct Static Pressure Inches (mm) 0.05-0.1"/1.27-2.54mm H2O
Performance Standard NSF/ANSI 49, EN 12469
Safety Certification UL, UL-C
Air Cleanliness (ISO 14644) ISO Class 5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor Dual Airflow Sensor
Control System TouchLink
Est. Shipping Weight lbs (kg) 690 lbs. / 313 kg.
Net Weight lbs (kg) 640 lbs. / 290 kg.

Review

Options

  • Stainless Steel Coved Interior, Cord Pass Through Right Sidewall, 2 Left Couplings, 1 Right Coupling and 1 Right Valve
  • Glass Side Walls, Stainless Steel Coved Interior, 2 Left Couplings, 1 Right Coupling and 1 Right Valve
  • 10-inch (254 mm) Access Opening, Manual Adjustable, Safety Plate Glass
  • 8-inch (203 mm) Access Opening, Manual Adjustable, Safety Plate Glass
  • 10-inch (254 mm) Access Opening, Automatic Adjustable, Safety Plate Glass
  • 115V, 60Hz, 20 Amp, NEMA 5-20P, Made in USA
  • 230V, 50/60 Hz, 15 Amp, Type F Plug, Made in USA
  • GFI, Qty 2 Duplex Outlets, NEMA 5-15R, 3 Amp Max, 115V
  • Qty 2 Duplex Outlets, NEMA 5-15R, 15 Amp Max, Dedicated NEMA 5-15P Power Cord, 115V
  • GFI, Qty 2 Duplex Outlets, NEMA 5-15R, 15 Amp Max, Dedicated NEMA 5-15P Power Cord, 115V
  • Qty 2 Duplex Outlets, NEMA 5-20R, 20 Amp Max, Dedicated NEMA 5-20P Power Cord, 115V
  • GFI, Qty 2 Duplex Outlets, NEMA 5-20R, 20 Amp Max, Dedicated NEMA 5-20P Power Cord, 115V
  • GFI, Qty 2 Duplex Outlets, NEMA 5-15R, 5 Amp Max, Removes Accessory Outlet, 115V
  • Qty 2, Socket Type B, 3 Amp Max, 230V
  • Qty 2, Socket Type D, 3 Amp Max, 230V
  • Qty 2, Socket Type E, 3 Amp Max, 230V
  • Qty 2, Socket Type F, 3 Amp Max, 230V
  • Qty 2, Socket Type G, 3 Amp Max, 230V
  • Qty 2, Socket Type H, 3 Amp Max, 230V
  • Qty 2, Socket Type I, 3 Amp Max, 230V
  • Qty 2, Socket Type J, 3 Amp Max, 230V
  • Qty 2, Socket Type K, 3 Amp Max, 230V
  • Qty 2, Socket Type M, 3 Amp Max, 230V
  • No UV Light, Field Retrofittable
  • UV Light Backwall
  • 3-inch (76 mm) Supply, 12-inch (305 mm) Exhaust Metal Frame Separatorless 99.99% @ 0.3 Micron HEPA Filters with Permanent Plenum
  • 3-inch (76 mm) Supply, 12-inch (305 mm) Exhaust Metal Frame Separatorless 99.995% @ MPPS H14 HEPA Filters with Permanent Plenum
  • 3-inch (76 mm) Supply, Redundant (Qty 2) 6-inch (152 mm) Exhaust Metal Frame Separatorless 99.995% @ MPPS H14 HEPA Filters with Permanent Plenum
  • IV Bar with 6 hooks and 3 height locations
  • Stainless Steel Window Edge Protector
  • Blower Contact Wires
  • Cord Pass-Thru Left Sidewall, NSF Approved
  • Power Cord with Twist Lock Plug, 115V, 60Hz, 20 Amp, NEMA 5-20P
  • Cable Management Brackets
  • Gas Supply Valve Interlock with Motor Blower
  • Left Top Service Valve
  • Left Middle Service Valve
  • Left Bottom Service Valve
  • Right Top Service Valve
  • Right Middle Service Valve
  • Right Bottom Service Coupling, Replaces Right Bottom Service Valve
  • Left Top Service Coupling
  • Right Top Service Coupling
  • Side Panels without Plumbing
  • Side Panels with Plumbing Out Bottom
  • Side Panels with Plumbing Out Top
  • Side Panels with Plumbing Out Back
  • Plumbing Line - Soft Copper 3/8-inch
  • Plumbing Line - Black Pipe 3/8-inch Gas Only
  • Plumbing Line - Rigid Copper 1/2-inch
  • Stainless Steel Flexible Pipe 96-inches (2439 mm)
  • CSST Yellow Flexible Pipe 96-inches (2439 mm)
  • Telescoping Base Stand with Levelers
  • Telescoping Base Stand with Casters
  • Motorized Base Stand with Leg Levelers
  • Motorized Base Stand with Casters
  • Telescoping Base Stand with Storage Cabinet with Leg Levelers
  • Telescoping Base Stand with Storage Cabinet with Casters
  • Telescoping Base Stand, Seismic/OPM with Leg Levelers Shipped Factory Assembled
  • Motorized Base Stand, Seismic Floor Mount with Leg Levelers
  • Base Stand Shelf 8-inches (203mm)
  • Base Stand Shelf 12-inches (305mm)
  • Ergotron Workstation for Telescoping Base Stand
  • Ergotron Workstation for Motorized Base Stand
  • Ergotron Laptop Arm for Telescoping Biosafety Cabinet Base Stands
  • Ergotron Laptop Arm for Automatic Adjustable Biosafety Cabinet Base Stands
  • Seismic Brackets, Rear Mount for Telescoping Base Stand
  • Seismic Brackets, Rear Mount for Motorized Base Stand
  • Seismic Brackets, Floor Mount for Telescoping Base Stand
  • Rear Closure Panel
  • Variable Range Low Flow Exhaust Canopy with Monitor, 10-inch (254 mm) Collar Diameter
  • Fixed Range Transition, 10-inch (254 mm) Collar Diameter
  • 25% Fill Activated Charcoal Filter Exhaust Transition
  • 25% Fill Purafill Filter Exhaust Transition
  • Rooster Low Airflow Alarm
  • Digital Manometer Monitor
  • Silicone Connection Sleeve Kit
  • Flex Duct, 10-inch (254 mm) Diameter, 8-feet (2.4 m), Qty 2 Stainless Steel Band Clamps
  • 10-inch (254 mm) Diameter Manual Air Tight Stainless Steel Butterfly Damper
  • Flex Duct, 8-inch (203 mm) Diameter, 8-feet (2.4 m), Qty 2 Stainless Steel Band Clamps
  • 8-inch (203 mm) Diameter Manual Air Tight Stainless Steel Butterfly Damper
  • 8-inch (203 mm) to 10-inch (254 mm) Round to Round Transition
  • Adjustable Footrest
  • Forearm Pad for Armrest (Disposable Pkg of 10)
  • Stainless Steel Table, Rotating, 12-inch (305 mm) Diameter
  • Silicone Pad Elbow Rest 3 x 5-inches (76 x 127 mm)
  • Silicone Pad Elbow Rest 3 x 10-inches (76 x 254 mm)
  • Ergonomic Accessory Kit

Request Your Quote for a NU-545

Please fill out the form below for a lab equipment quote and we'll get to work on getting you what you need. Need to talk with someone right away? Give us a call at 763-553-1270.

Thank you for completing the form.

We will be in touch. If you have any urgent questions, please reach out at 763-553-1270.