Products

Biological Safety Cabinets & Enclosures

Request Your Quote

NuAire is a lead manufacturer of ergonomic and environmentally friendly biosafety cabinets (BSCs), also known as biological safety cabinets or enclosures. Harnessing the power of HEPA filters and laminar airflow, our biosafety cabinets provide personnel, product, and environmental protection from hazardous biological material to ensure a ISO Class 5 work zone.

The downflow air passes through a HEPA filter, preventing biohazard exposure and potential cross-contamination. A similar process occurs for the exhausted air before environmental release to prevent unnecessary damage and contamination.

Our biosafety cabinets provide the utmost protection and reduce the potential for exposure while allowing users to obtain optimum control over product quality.

NuAire offers NSF/ANSI 49 and EN12469 certified Class I and Class II BSCs. We also offer a range of ergonomically designed bench top and console biosafety models that can be recirculated back into the laboratory environment or through a facility exhaust system.

Shop all biosafety cabinet models below or contact NuAire to discuss your laboratory protection needs today.

Request Your Quote
Precision-engineered for premium protection and superior containment. Trusted by leading laboratories worldwide. Ergonomic design enhances user comfort and productivity. Robust construction ensures reliable, long-lasting performance for critical research.

Curious about QuickShip?

Application

x

Control System

x

Electrical

x

Performance Standard

x

Shipping Options

x

Width

x

Work Access Opening

x
{count} results

FAQ

What are the different types of biosafety cabinets, and how do I choose the right one for my lab?

Biosafety cabinets (BSCs) are classified into three primary classes based on the level of protection they provide. Learn more about biosafety cabinet classes:

  • Class I: Protects personnel and the environment by filtering air before it is exhausted. It does not protect products since unfiltered room air flows over the work surface. Learn how Class I cabinets work 
  • Class II: Provides protection for personnel, the product, and the environment. Class II BSCs are subdivided into five types: Explore Class II cabinet types 
    • Type A1: Rarely used in the industry today due to safety and exhaust handling limitations.
    • Type A2: The most common BSC type. It recirculates approximately 70% of air through a HEPA filter and exhausts 30%. It can handle trace amounts of volatile chemicals if externally vented. Learn how Type A2 cabinets work 
    • Type B1: Recirculates 30% of air and exhausts 70%, suitable for work with low amounts of toxic chemicals and radionuclides. It offers a dedicated exhaust portion of the work surface for minimal volatile chemical use. Learn how Type B1 cabinets work
    • Type B2: 100% of the air is exhausted to the outside, making it ideal for use with hazardous chemicals or pathogens. Learn how Type B2 cabinets work 
    • Type C1: A hybrid cabinet that offers both recirculation and limited exhaust capabilities, depending on the application. Learn about Type C1 cabinets 
  • Class III: A fully enclosed, gas-tight cabinet that provides the highest level of protection for personnel, product, and the environment. These are typically used for highly hazardous agents, such as in BSL-4 laboratories. Learn how Class III cabinets work 

What kind of protection do biosafety cabinets provide for personnel, product, and the environment?

Biosafety cabinets (BSCs) provide protection in three key areas:

  • Personnel: Contain harmful agents to prevent exposure.
  • Product: Maintain a sterile environment for sensitive materials.
  • Environment: Contain contaminants to prevent environmental exposure.

How often should the biosafety cabinet be certified and serviced?

Biosafety cabinets (BSCs) must be certified at least annually by a qualified technician, as required by NSF/ANSI 49 standards. Certification ensures proper airflow, filter integrity, and overall cabinet performance to maintain personnel, product, and environmental protection. During certification, technicians test airflow patterns, check filter integrity, and confirm that the cabinet meets performance specifications.

For facilities operating under USP <797> or USP <800> standards (e.g., sterile compounding pharmacies), certification is required biannually (every six months) to ensure compliance with strict air cleanliness and containment requirements. Learn more about field certification requirements.

Additional notes:

  • Regular Maintenance: Routine cleaning, pre-filter inspections, and airflow monitoring are essential to extend the life of the equipment and maintain safety.
  • HEPA Filter Checks: Depending on workload and environment, filters should be inspected during certification and replaced as necessary.

Can my biosafety cabinet handle chemical fumes or vapors?

  • Type A2: Handles trace amounts of chemicals if externally vented.
  • Type B1: Offers a dedicated exhaust portion for minimal volatile chemical use and limited exhaust capabilities.
  • Type B2: Fully exhausts all air, suitable for significant hazardous chemical use.
  • Type C1: A hybrid cabinet for occasional exhaust of limited chemical vapors.

The CDC/NIH Biosafety in Microbiological and Biomedical Laboratories (BMBL) 6th Edition provides detailed guidelines on the use of biosafety cabinets with volatile chemicals. According to the BMBL:

  • BSCs that recirculate air, such as Class II Type A1/A2, are generally not suitable for use with hazardous volatile chemicals or radionuclides unless externally vented.
  • Class II Type B1 and B2 cabinets are more appropriate for chemical vapor containment. Type B1 provides partial exhaust, while Type B2 fully exhausts all air, making it ideal for hazardous chemicals.
  • HEPA filters do not capture chemical vapors, which must be properly vented outside the lab to prevent accumulation.

How long do HEPA filters last, and when should they be replaced?

HEPA filters typically last several years, but their lifespan depends on usage, load, and environmental factors. Regular airflow monitoring and annual certification help determine replacement needs. Learn more about HEPA filter lifespan. 

What should I do if airflow alarms or pressure monitors indicate an issue?

  • Stop work immediately.
  • Check controls: Review the system for diagnostics.
  • Call for service: Contact a certified technician to resolve the issue.

For detailed guidance on responding to alarms, visit Reacting to Alarms in Class II, Type A2 Biosafety Cabinets. 

How do I properly clean and decontaminate the biosafety cabinet?

  • Use a disinfectant: Choose a disinfectant appropriate for the contaminants being handled (e.g., bleach or ethanol).
  • Clean work surfaces: Wipe down the work surface and clean beneath the tray if accessible.
  • Maintain pre-filters: Regularly check and clean pre-filters or drainage systems to ensure proper airflow and drainage.

For more details, refer to Surface Decontamination in a Biosafety Cabinet or learn about Containing Spills in Class II, Type A2 Biosafety Cabinets.

Can the biosafety cabinet accommodate ergonomic adjustments for different users?

Many biosafety cabinets (BSCs) feature adjustable bases, sloped front windows, and spacious work zones to reduce strain during use. Some models also include height adjustability, allowing for comfortable operation in both seated and standing positions. Learn more about ergonomic features in biosafety cabinets. 

How much noise does the biosafety cabinet produce?

Modern biosafety cabinets (BSCs) are designed to operate at low noise levels, typically under 60 dBA, which is quieter than a normal conversation. This low noise level ensures a comfortable work environment and reduces distractions for laboratory personnel during prolonged tasks.

The NSF/ANSI 49 standard specifies that the overall noise level in front of the cabinet should not exceed 67 dBA when the ambient noise level in the room is 57 dBA or lower. Measurements are taken 12 inches in front of the cabinet’s leading edge and 15 inches above the work surface, simulating the position of the user’s head. For comparison, the EN12469 standard measures noise at a point 1 meter from the cabinet and centered on the aperture, resulting in slightly lower reported dBA values. This distinction in testing methods is important when comparing noise data across standards.

Noise levels can also vary depending on ambient sound, room acoustics, and the presence of other equipment. Cabinets placed in smaller rooms may seem louder due to sound reflections, even if their noise levels are within certified limits. Advanced fan motor designs and the use of EC or DC motors in modern BSCs help minimize noise generated by airflow and mechanical vibrations.

For additional details, refer to the Noise Considerations in Laboratories Bulletin.

What kind of maintenance and repairs can I perform on my biosafety cabinet?

Basic maintenance tasks such as cleaning surfaces and replacing pre-filters (if present) can typically be performed by lab personnel. These routine actions help maintain cleanliness and ensure optimal airflow. However, more complex tasks, such as HEPA filter replacement and airflow adjustments, should always be handled by certified technicians to ensure safety and compliance with standards.

For guidance on basic maintenance, refer to Checking the Paper Catch in a Biosafety Cabinet. For broader operational best practices, explore Working Safely in Class II, Type A2 Biosafety Cabinets.


REQUEST Your QUOTE

PLEASE FILL OUT THE FORM AND WE’LL GET TO WORK ON GETTING YOU WHAT YOU NEED.

How it works. NuAire sells through a network of knowledge representatives, some who have been selling and servicing NuAire since our inception in 1971. We’ll notify your local representative who will reach out to you. He/She can assist with product selection/configuration, training, installation guidance, support throughout the life of the product, or just provide you pricing in a quick manner. We have some of the best customers who are doing some groundbreaking work. We would love for you to join our family and experience the NuAire Advantage.

Why Your Colleagues Choose NuAire

Let me say that we have come to rely on Nuaire, as a strong partner to Vaccines & it is so because of our valued relationship with George Riley, who is always at our beck and call. God bless him (Keep him for Sure!!) & your Quality BioSafety Cabinets. Service is King & Quality is his side-kick!! So thank you! We look forward to a long and prosperous relationship. Keep up the good work & quality build.

Operations Manager at a Large Pharmaceutical Company
labrepco.com