Application

medication workflow

Medication Workflow Compatible Biosafety Cabinets and Laminar Airflow Workstations

IV workflow systems that utilize barcoding and gravimetric technology enable real time error detection during Medication compounding. These systems standardize the workflow, increasing safety, while enabling inventory optimization, efficiency, and compliance.

Just as IV Workflow Systems have improved the safety and efficiency of compounding, NuAire has developed pharmacy equipment configured to maximize safety and protection along with improving workflow efficiency and ergonomics.

Compounding Pharmacy Medication Workflow

Application

medication workflow

IV workflow systems that utilize barcoding and gravimetric technology enable real time error detection during Medication compounding. These systems standardize the workflow, increasing safety, while enabling inventory optimization, efficiency, and compliance.

Just as IV Workflow Systems have improved the safety and efficiency of compounding, NuAire has developed pharmacy equipment configured to maximize safety and protection along with improving workflow efficiency and ergonomics.

Related Products

Sterile Non-Hazardous Primary Engineering Control (PEC)

Vertical Laminar Airflow Workstation Model NU-140

The AireGard™ Vertical Laminar Airflow Workstations (LAFW) model NU-140 is designed as a table top cabinet that features the newest technologies in laminar airflow design, materials and manufacturing processes. The clean workstation can be used where clean airflow per ISO 14644-1 is required for the preparation of injectable drugs, IV solutions, tissue culture, optics, microelectronics, etc. The clean workstation is used to protect the product from contamination. The clean workstation is optionally available with a base stand, placing the work surface at 30” (762mm) or 36” (914mm). A significant number of design innovations give the NuAire Laminar flow equipment superior performance qualities in airflow, lighting, noise levels and vibration.

Learn More

Sterile Non-Hazardous Primary Engineering Control (PEC)

Horizontal Laminar Airflow Workstation Model NU-240

The AireGard™ Horizontal Laminar Airflow Workstations (LAFW) model NU-240 is designed as a table top clean bench that features the newest technologies in laminar airflow design, materials and manufacturing processes. The clean workstation can be used where clean airflow per ISO 14644-1 is required for the preparation of injectable drugs, IV solutions, tissue culture, optics, microelectronics, etc. The clean workstation is used to protect work product from contamination. The clean workstation is available with an optional base stand, placing the work surface at 30” (762mm) or 36” (914mm). A significant number of design innovations give the NuAire Laminar flow equipment superior performance qualities in airflow, lighting, noise levels and vibration.

Learn More

Sterile Non-Hazardous Primary Engineering Control (PEC)

Horizontal Laminar Airflow Workstation Model NU-340

The AireGard model NU-340 is a console-style Horizontal Laminar Airflow Workstation (LAFW) designed to provide clean airflow per ISO 14644-1 for the preparation of injectable drugs, IV solutions, tissue culture, optics, microelectronics, and more. Model NU-340 offers product protection through the use of HEPA filtered airflow in a horizontal laminar direction over the work surface. AireGard provides long-lasting performance with energy saving technology. The clean workstation is used to protect work product from contamination. A significant number of design innovations give the NuAire Laminair flow equipment superior performance qualities.

Learn More
Class II Biosafety Cabinet model NU-543 configured for sterile hazardous drug compounding featuring a smooth interior, telescoping base stand with leg levelers, exhaust transition with alarm, and an ergo-tron arm for a computer monitor, mouse and keyboard.

Sterile Hazardous Containment Primary Engineering Control (C-PEC)

Class II, Type A2 Biosafety Cabinet model NU-543

The LabGard® NU-543 is a Class II Type A2 Biosafety Cabinet (BSC) known as a containment primary engineering control (C-PEC) that can connected to a facility HVAC system through an exhaust transition per USP 800. The cabinet’s airflow is 30% exhausted / 70% recirculated.

Learn More

Sterile Hazardous Containment Primary Engineering Control (C-PEC)

Class II, Type B2 Biosafety Cabinet Model NU-560

The LabGard® ES (Energy Saver) TE (Total Exhaust) NU-560 Biosafety Cabinet (BSC) is a bench/table top model, optionally available with a base support stand, for operation as a console model. The LabGard ES model NU-560 utilizes an Energy Saver DC ECM motor optimally determined forward curved fan for each model size/width to maximize both energy efficiency and filter loading capacity. The Energy Saver ECM motor is controlled to airflow setpoints via a solid-state DC motor controller with digital dual thermistor airflow sensors that provide an automatic compensation (constant volume control) for both filter loading and line voltage variances.

Learn More

Related Resources

Infographic

USP 797 and USP 800 PEC Requirements

Follow this flowchart for an easy method to identify what Primary Engineering Control (PEC) or Containment Primary Engineering Control (C-PEC) your pharmacy needs.
Webinar

USP Compliance Safe Implementation of PECs Under USP 797 and 800

Jim Wagner reviews the impact of the changes to USP <797> with regard to PEC implementation & USP <800> requirements for containment.
White Paper

Facility and Engineering Control Design Under USP 800

Design considerations for creating a Pharmacy USP 800 compliant Hazardous Drug (HD) compounding operation.
Webinar

Engineering Control Options Under USP 800

Explore USP 800 engineering controls in our webinar with expert Bryan Prince. Learn about air handling and facility design for pharmacy safety.
Webinar

USP Compliance Staff Training for USP

Fred Massoomi, PharmD, FASHP, reviews staffing considerations under USP 800 including topics such as the value of didactic and experiential training and how to establish training by position.