LabGard ES NU-540 Class II Type A2 Biosafety Cabinet
- Overview
- Specifications
- Reviews
- Resources
- Options
Overview
AeroMax Control System
The AeroMax control system visualizes airflow plenum pressure through a series of multicolored lights and activates both an audible and visual alarm whenever cabinet performance departs from normal parameters.
Ultra High Efficiency Motor
A single DC ECM motor with a precision-engineered forward curved fan powers airflow through the biosafety cabinet. The ultra-high efficiency motor lowers energy costs and reduces noise pollution but is powerful enough to extend filter life. The one motor design allows for easy certification and airflow balancing. In addition, it provides enough power to compensate for HEPA filter loading, reducing filter changes and lowering the total ownership cost.
HEPEX Zero Leak Airflow System
Our signature flexible plenum design complements the ultra-high efficiency motor to uniformly distribute the downflow air across the supply HEPA filter into the work zone in a laminar or unidirectional pattern. The flexible plenum insulates the transmission path of any vibration and noise produced by the motor blower protecting sensitive cells and reducing noise pollution. The HEPEX material is tear and abrasion-resistant, flame retardant, and impermeable to gases, fluids, and dust reducing contamination risks making it the perfect solution for biomedical/microbiological and hazardous drug compounding work. All filter seals are kept under negative pressure. In the event of a potential leak, air will recirculate back through the motor blower and into the plenum.
Monolithic Construction
At the heart of any NuAire biosafety cabinet is its construction. The NuAire design centers on the use of high-quality stainless steel and seam welding to eliminate leak risks that come with the use of multi-piece shells put together with gaskets, sealants, and rivets. The NuAire BSC uses a coved stainless steel interior inserted into a larger wrap that makes up the cabinet walls. The top and bottom catch tray is seam welded into place, creating a monolithic leak-free cabinet shell designed to provide long-lasting maximum safety.
Specifications
Blower Contact Wires | Optional |
Closure Panels | Optional Rear Closure Panels for Seismic Brackets |
Cord Pass Through | Standard Right, Optional Left |
Double Exhaust HEPA Filter | N/A |
Gas Supply Interlock with Blower | N/A |
Glass Sidewalls | N/A |
IV Bar with 6 Hooks | Optional |
Magnifying Glass in Window | N/A |
Motorized Base Stand | Optional as Separate Accessory |
Motorized Window | N/A |
Other Built-in Supply Filter Option(s) | N/A |
Outlet(s) | Standard, two backwall |
Plumbing | Optional 3/8" Soft Copper, 3/8" Black Pipe (Gas Only), or 1/2" Rigid Copper |
Remote Service Valves | N/A |
Seismic Brackets or Studs | Optional Rear or Floor Mount Seismic Brackets |
Service Couplings (3/8-inch NPT) | Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Three Each Side Wall Optional |
Service Valves (3/8-inch NPT) | One Valve on Right Side Wall is Standard, Maximum of Three Each Side Wall Optional |
Side Panels | Optional with Plumbing out Bottom, Top or Back |
Smooth Interior | N/A |
Ultraviolet (UV) Light | Optional |
Window Edge Protector | Optional |
Access Opening Glass Type | Tempered |
Armrest | Standard Plastic with Optional Stainless Steel |
Cabinet Construction | All welded stainless steel 16/18 GA, Type 304 pressure tight design |
Casters | N/A |
Decontamination Seal-able Window | N/A |
Diffuser | Metal, non-flammable |
Drain Valve Location | Front right |
Exhaust Filter | 6-inch (152 mm) 99.99% Efficiency on 0.3 microns |
Front & Control Panel Material | Painted Steel |
HEPA Filter Seal Type | HEPEX Zero Leak Neoprene Seal, Spring-loaded |
Lighting | LED |
Main Cabinet Wrap | Single Piece Stainless Steel Side and Back Wall Construction |
Motor(s) | 1/2 HP DC ECM |
Plenum Type | HEPEX |
Pre-filter | N/A |
Style | Bench top, optional base stand |
Supply Filter | 3-inch (76mm) 99.99% Efficiency on 0.3 microns |
Viewing Window Inches (mm) | 21 (533) open to fully closed |
Work Access Opening(s) | 8, 10-inch (203, 254 mm) |
Work Surface | One-Piece Dished Stainless Steel with Prop-Up Rod |
Work Zone Wrap | Single Piece Stainless Steel Side and Back Wall Construction |
Data Output Features | RS-232 |
Remote Alarm Terminals | Standard |
Est. Shipping Depth Inches (mm) | 43 (1092) |
Est. Shipping Height Inches (mm) | 71 (1803) |
Est. Shipping Width Inches (mm) | 46 (1168) |
Exterior Depth Inches (mm) | 32 1/8 (817) |
Exterior Depth with Armrest Removed Inches (mm) | 31 7/16 (799) |
Exterior Height (Minimum for Transport) Inches (mm) | 59 (1499) |
Exterior Height Inches (mm) | 60 7/8 (1546) |
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) | 87.375 (2219) |
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) | 93.375 (2371) |
Exterior Width Inches (mm) | 41 5/8 (1057) |
Nominal Width Feet (Meters) | 3 ft. (0.9m) |
Useable Work Tray Area Depth Inches (mm) | 20 7/8 (530) |
Useable Work Tray Area Width Inches (mm) | 33 7/8 (860) |
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) | 25 3/4 (654) |
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) | N/A |
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) | N/A |
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) | Inquire |
Work Area Height Inches (mm) | 28 1/2 (724) |
Work Area Width Inches (mm) | 34 3/8 (873) |
Blower/Lights Amps [10-inch (254 mm) Access Opening] | 2.3 |
Blower/Lights Amps [12-inch (305 mm) Access Opening] | |
Blower/Lights Amps [14-inch (356mm) Access Opening] | |
Blower/Lights Amps [8-inch (203 mm) Access Opening] | 2.1 |
Electrical Configuration | 115V60Hz |
Junction Box | Optional |
Outlet Amps | 3 |
Power Cord | Single 12-foot (3.7m) 14 GA - 3 Wire, 15A |
Power Cord Length Foot (Meter) | 12 (3.7) |
Rated Amps | 10 |
Light Intensity fc (Lux) | 90-120 (968-1291) |
Reach into workzone Inches (mm) | 6 (152) |
Sound Pressure Level per ISO 4871 | ≤ 55dba |
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) | 320 (544) |
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) | 276-501 (649-851) |
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) | N/A |
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) | N/A |
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) | N/A |
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) | N/A |
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) | 269 (457) |
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) | 255-450 (383-765) |
Bag In Bag Out | N/A |
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) | 903 |
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) | N/A |
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) | N/A |
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) | 826 |
Heat Rejected Vented (BTU/Hour) | 120 |
Other Built-in Exhaust Option(s) | N/A |
Plant Duct Static Pressure Inches (mm) | 0.05-0.1"/1.27-2.54mm H2O |
Australian Test Method | N/A |
Performance Standard | NSF-ANSI-49 |
Safety Certification |
Air Cleanliness (ISO 14644) | ISO-Class-5 |
Downflow fpm (m/s) | 60 fpm (0.30 m/s) |
Fumigation: per NIH/NSF Procedures | True |
Inflow fpm (m/s) | 105 fpm (0.53 m/s) |
Protection | Product, Personnel, Environmental |
Airflow Monitor | Pressure |
Control System | AeroMax |
Est. Shipping Weight lbs (kg) | 450 lbs. / 204 kg. |
Net Weight lbs (kg) | 400 lbs. /181 kg. |
Blower Contact Wires | Optional |
Closure Panels | Optional Rear Closure Panels for Seismic Brackets |
Cord Pass Through | Standard Right, Optional Left |
Double Exhaust HEPA Filter | N/A |
Gas Supply Interlock with Blower | N/A |
Glass Sidewalls | N/A |
IV Bar with 6 Hooks | Optional |
Magnifying Glass in Window | N/A |
Motorized Base Stand | Optional as Separate Accessory |
Motorized Window | N/A |
Other Built-in Supply Filter Option(s) | N/A |
Outlet(s) | Standard, two backwall |
Plumbing | Optional 3/8" Soft Copper, 3/8" Black Pipe (Gas Only), or 1/2" Rigid Copper |
Remote Service Valves | N/A |
Seismic Brackets or Studs | Optional Rear or Floor Mount Seismic Brackets |
Service Couplings (3/8-inch NPT) | Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Three Each Side Wall Optional |
Service Valves (3/8-inch NPT) | One Valve on Right Side Wall is Standard, Maximum of Three Each Side Wall Optional |
Side Panels | Optional with Plumbing out Bottom, Top or Back |
Smooth Interior | N/A |
Ultraviolet (UV) Light | Optional |
Window Edge Protector | Optional |
Access Opening Glass Type | Tempered Glass |
Armrest | Standard Plastic with Optional Stainless Steel |
Cabinet Construction | All welded stainless steel 16/18 GA, Type 304 pressure tight design |
Casters | N/A |
Decontamination Seal-able Window | N/A |
Diffuser | Metal, non-flammable |
Drain Valve Location | Front right |
Exhaust Filter | 6-inch (152 mm) 99.99% Efficiency on 0.3 microns |
Front & Control Panel Material | Painted Steel |
HEPA Filter Seal Type | HEPEX Zero Leak Neoprene Seal, Spring-loaded |
Lighting | LED |
Main Cabinet Wrap | Single Piece Stainless Steel Side and Back Wall Construction |
Motor(s) | 1/2 HP DC ECM |
Plenum Type | HEPEX |
Pre-filter | N/A |
Style | Bench top, optional base stand |
Supply Filter | 3-inch (76mm) 99.99% Efficiency on 0.3 microns |
Viewing Window Inches (mm) | 21 (533) open to fully closed |
Work Access Opening(s) | 10-inch (254 mm) |
Work Surface | One-Piece Dished Stainless Steel with Prop-Up Rod |
Work Zone Wrap | Single Piece Stainless Steel Side and Back Wall Construction |
Data Output Features | RS-232 |
Remote Alarm Terminals | Standard |
Est. Shipping Depth Inches (mm) | 71 (1803) |
Est. Shipping Height Inches (mm) | 43 (1092) |
Est. Shipping Width Inches (mm) | 46 (1168) |
Exterior Depth Inches (mm) | 32 1/8 (817) |
Exterior Depth with Armrest Removed Inches (mm) | 31 7/16 (799) |
Exterior Height (Minimum for Transport) Inches (mm) | 59 (1499) |
Exterior Height Inches (mm) | 60 7/8 (1546) |
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) | 88 3/8 (2245) |
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) | 94 3/8 (2397) |
Exterior Width Inches (mm) | 41 5/8 (1057) |
Nominal Width Feet (Meters) | 3 ft. (0.9m) |
Useable Work Tray Area Depth Inches (mm) | 20 7/8 (530) |
Useable Work Tray Area Width Inches (mm) | 33 7/8 (860) |
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) | 25 3/4 (654) |
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) | N/A |
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) | N/A |
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) | N/A |
Work Area Height Inches (mm) | 28 1/2 (724) |
Work Area Width Inches (mm) | 34 3/8 (873) |
Blower/Lights Amps [10-inch (254 mm) Access Opening] | 2.3 |
Blower/Lights Amps [12-inch (305 mm) Access Opening] | |
Blower/Lights Amps [14-inch (356mm) Access Opening] | |
Blower/Lights Amps [8-inch (203 mm) Access Opening] | |
Electrical Configuration | 230V5060Hz |
Junction Box | Optional |
Outlet Amps | 3 |
Power Cord | Single 12-foot (3.7m) 14 GA - 3 Wire, 15A |
Power Cord Length Foot (Meter) | 12 (3.7) |
Rated Amps | 8 |
Light Intensity fc (Lux) | 90-120 (968-1291) |
Reach into workzone Inches (mm) | 6 (152) |
Sound Pressure Level per ISO 4871 | ≤ 55dba |
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) | 320 (544) |
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) | 276-501 (649-851) |
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) | N/A |
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) | N/A |
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) | N/A |
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) | N/A |
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) | N/A |
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) | N/A |
Bag In Bag Out | N/A |
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) | 903 |
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) | N/A |
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) | N/A |
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) | N/A |
Heat Rejected Vented (BTU/Hour) | 120 |
Other Built-in Exhaust Option(s) | N/A |
Plant Duct Static Pressure Inches (mm) | 0.05-0.1"/1.27-2.54mm H2O |
Australian Test Method | N/A |
Performance Standard | NSF-ANSI-49 |
Safety Certification |
Air Cleanliness (ISO 14644) | ISO-Class-5 |
Downflow fpm (m/s) | 60 fpm (0.30 m/s) |
Fumigation: per NIH/NSF Procedures | True |
Inflow fpm (m/s) | 105 fpm (0.53 m/s) |
Protection | Product, Personnel, Environmental |
Airflow Monitor | Pressure |
Control System | AeroMax |
Est. Shipping Weight lbs (kg) | 450 lbs. / 204 kg. |
Net Weight lbs (kg) | 400 lbs. /181 kg. |
Blower Contact Wires | Optional |
Closure Panels | Optional Rear Closure Panels for Seismic Brackets |
Cord Pass Through | Standard Right, Optional Left |
Double Exhaust HEPA Filter | N/A |
Gas Supply Interlock with Blower | N/A |
Glass Sidewalls | N/A |
IV Bar with 6 Hooks | Optional |
Magnifying Glass in Window | N/A |
Motorized Base Stand | Optional as Separate Accessory |
Motorized Window | N/A |
Other Built-in Supply Filter Option(s) | N/A |
Outlet(s) | Standard, two backwall |
Plumbing | Optional 3/8" Soft Copper, 3/8" Black Pipe (Gas Only), or 1/2" Rigid Copper |
Remote Service Valves | N/A |
Seismic Brackets or Studs | Optional Rear or Floor Mount Seismic Brackets |
Service Couplings (3/8-inch NPT) | Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Three Each Side Wall Optional |
Service Valves (3/8-inch NPT) | One Valve on Right Side Wall is Standard, Maximum of Three Each Side Wall Optional |
Side Panels | Optional with Plumbing out Bottom, Top or Back |
Smooth Interior | N/A |
Ultraviolet (UV) Light | Optional |
Window Edge Protector | Optional |
Access Opening Glass Type | Tempered |
Armrest | Standard Plastic with Optional Stainless Steel |
Cabinet Construction | All welded stainless steel 16/18 GA, Type 304 pressure tight design |
Casters | N/A |
Decontamination Seal-able Window | N/A |
Diffuser | Metal, non-flammable |
Drain Valve Location | Front right |
Exhaust Filter | 6-inch (152 mm) 99.99% Efficiency on 0.3 microns |
Front & Control Panel Material | Painted Steel |
HEPA Filter Seal Type | HEPEX Zero Leak Neoprene Seal, Spring-loaded |
Lighting | LED |
Main Cabinet Wrap | Single Piece Stainless Steel Side and Back Wall Construction |
Motor(s) | 1/2 HP DC ECM |
Plenum Type | HEPEX |
Pre-filter | N/A |
Style | Bench top, optional base stand |
Supply Filter | 3-inch (76mm) 99.99% Efficiency on 0.3 microns |
Viewing Window Inches (mm) | 21 (533) open to fully closed |
Work Access Opening(s) | 8, 10-inch (203, 254 mm) |
Work Surface | One-Piece Dished Stainless Steel with Prop-Up Rod |
Work Zone Wrap | Single Piece Stainless Steel Side and Back Wall Construction |
Data Output Features | RS-232 |
Remote Alarm Terminals | Standard |
Est. Shipping Depth Inches (mm) | 43 (1092) |
Est. Shipping Height Inches (mm) | 71 (1803) |
Est. Shipping Width Inches (mm) | 59 (1499) |
Exterior Depth Inches (mm) | 32 1/8 (817) |
Exterior Depth with Armrest Removed Inches (mm) | 31 7/16 (799) |
Exterior Height (Minimum for Transport) Inches (mm) | 59 (1499) |
Exterior Height Inches (mm) | 60 7/8 (1546) |
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) | 87.375 (2219) |
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) | 93.375 (2371) |
Exterior Width Inches (mm) | 53 5/8 (1362) |
Nominal Width Feet (Meters) | 4 ft. (1.2m) |
Useable Work Tray Area Depth Inches (mm) | 20 7/8 (530) |
Useable Work Tray Area Width Inches (mm) | 45 7/8 (1165) |
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) | 25 3/4 (654) |
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) | N/A |
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) | N/A |
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) | Inquire |
Work Area Height Inches (mm) | 28 1/2 (724) |
Work Area Width Inches (mm) | 46 3/8 (1178) |
Blower/Lights Amps [10-inch (254 mm) Access Opening] | 2.9 |
Blower/Lights Amps [12-inch (305 mm) Access Opening] | |
Blower/Lights Amps [14-inch (356mm) Access Opening] | |
Blower/Lights Amps [8-inch (203 mm) Access Opening] | 2.6 |
Electrical Configuration | 115V60Hz |
Junction Box | Optional |
Outlet Amps | 3 |
Power Cord | Single 12-foot (3.7 m) 14 GA - 3 Wire, 15A |
Power Cord Length Foot (Meter) | 12 (3.7) |
Rated Amps | 12 |
Light Intensity fc (Lux) | 90-120 (968-1291) |
Reach into workzone Inches (mm) | 6 (152) |
Sound Pressure Level per ISO 4871 | ≤ 56 dba |
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) | 426 (724) |
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) | 363-588 (617-1000) |
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) | N/A |
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) | N/A |
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) | N/A |
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) | N/A |
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) | 359 (610) |
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) | 295-520 (502-884) |
Bag In Bag Out | N/A |
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) | 1140 |
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) | N/A |
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) | N/A |
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) | 1020 |
Heat Rejected Vented (BTU/Hour) | 157 |
Other Built-in Exhaust Option(s) | N/A |
Plant Duct Static Pressure Inches (mm) | 0.05-0.1"/1.27-2.54mm H2O |
Australian Test Method | N/A |
Performance Standard | NSF-ANSI-49 |
Safety Certification |
Air Cleanliness (ISO 14644) | ISO-Class-5 |
Downflow fpm (m/s) | 60 fpm (0.30 m/s) |
Fumigation: per NIH/NSF Procedures | True |
Inflow fpm (m/s) | 105 fpm (0.53 m/s) |
Protection | Product, Personnel, Environmental |
Airflow Monitor | Pressure |
Control System | AeroMax |
Est. Shipping Weight lbs (kg) | 515 lbs. / 234 kg. |
Net Weight lbs (kg) | 465 lbs. / 211 kg. |
Blower Contact Wires | Optional |
Closure Panels | Optional Rear Closure Panels for Seismic Brackets |
Cord Pass Through | Standard Right, Optional Left |
Double Exhaust HEPA Filter | N/A |
Gas Supply Interlock with Blower | N/A |
Glass Sidewalls | N/A |
IV Bar with 6 Hooks | Optional |
Magnifying Glass in Window | N/A |
Motorized Base Stand | Optional as Separate Accessory |
Motorized Window | N/A |
Other Built-in Supply Filter Option(s) | N/A |
Outlet(s) | Standard, two backwall |
Plumbing | Optional 3/8" Soft Copper, 3/8" Black Pipe (Gas Only), or 1/2" Rigid Copper |
Remote Service Valves | N/A |
Seismic Brackets or Studs | Optional Rear or Floor Mount Seismic Brackets |
Service Couplings (3/8-inch NPT) | Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Three Each Side Wall Optional |
Service Valves (3/8-inch NPT) | One Valve on Right Side Wall is Standard, Maximum of Three Each Side Wall Optional |
Side Panels | Optional with Plumbing out Bottom, Top or Back |
Smooth Interior | N/A |
Ultraviolet (UV) Light | Optional |
Window Edge Protector | Optional |
Access Opening Glass Type | Tempered Glass |
Armrest | Standard Plastic with Optional Stainless Steel |
Cabinet Construction | All welded stainless steel 16/18 GA, Type 304 pressure tight design |
Casters | N/A |
Decontamination Seal-able Window | N/A |
Diffuser | Metal, non-flammable |
Drain Valve Location | Front right |
Exhaust Filter | 6-inch (152 mm) 99.99% Efficiency on 0.3 microns |
Front & Control Panel Material | Painted Steel |
HEPA Filter Seal Type | HEPEX Zero Leak Neoprene Seal, Spring-loaded |
Lighting | LED |
Main Cabinet Wrap | Single Piece Stainless Steel Side and Back Wall Construction |
Motor(s) | 1/2 HP DC ECM |
Plenum Type | HEPEX |
Pre-filter | N/A |
Style | Bench top, optional base stand |
Supply Filter | 3-inch (76mm) 99.99% Efficiency on 0.3 microns |
Viewing Window Inches (mm) | 21 (533) open to fully closed |
Work Access Opening(s) | 10-inch (254 mm) |
Work Surface | One-Piece Dished Stainless Steel with Prop-Up Rod |
Work Zone Wrap | Single Piece Stainless Steel Side and Back Wall Construction |
Data Output Features | RS-232 |
Remote Alarm Terminals | Standard |
Est. Shipping Depth Inches (mm) | 43 (1092) |
Est. Shipping Height Inches (mm) | 71 (1803) |
Est. Shipping Width Inches (mm) | 59 (1499) |
Exterior Depth Inches (mm) | 32 1/8 (817) |
Exterior Depth with Armrest Removed Inches (mm) | 31 7/16 (799) |
Exterior Height (Minimum for Transport) Inches (mm) | 59 (1499) |
Exterior Height Inches (mm) | 60 7/8 (1546) |
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) | 88 3/8 (2245) |
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) | 94 3/8 (2397) |
Exterior Width Inches (mm) | 53 5/8 (1362) |
Nominal Width Feet (Meters) | 4 ft. (1.2m) |
Useable Work Tray Area Depth Inches (mm) | 20 7/8 (530) |
Useable Work Tray Area Width Inches (mm) | 45 7/8 (1165) |
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) | 25 3/4 (654) |
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) | N/A |
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) | N/A |
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) | N/A |
Work Area Height Inches (mm) | 28 1/2 (724) |
Work Area Width Inches (mm) | 46 3/8 (1178) |
Blower/Lights Amps [10-inch (254 mm) Access Opening] | 2.9 |
Blower/Lights Amps [12-inch (305 mm) Access Opening] | |
Blower/Lights Amps [14-inch (356mm) Access Opening] | |
Blower/Lights Amps [8-inch (203 mm) Access Opening] | |
Electrical Configuration | 230V5060Hz |
Junction Box | Optional |
Outlet Amps | 3 |
Power Cord | Single 12-foot (3.7 m) 14 GA - 3 Wire, 15A |
Power Cord Length Foot (Meter) | 12 (3.7) |
Rated Amps | 10 |
Light Intensity fc (Lux) | 90-120 (968-1291) |
Reach into workzone Inches (mm) | 6 (152) |
Sound Pressure Level per ISO 4871 | ≤ 56 dba |
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) | 426 (724) |
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) | 363-588 (617-1000) |
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) | N/A |
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) | N/A |
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) | N/A |
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) | N/A |
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) | N/A |
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) | N/A |
Bag In Bag Out | N/A |
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) | 1140 |
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) | N/A |
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) | N/A |
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) | N/A |
Heat Rejected Vented (BTU/Hour) | 157 |
Other Built-in Exhaust Option(s) | N/A |
Plant Duct Static Pressure Inches (mm) | 0.05-0.1"/1.27-2.54mm H2O |
Australian Test Method | N/A |
Performance Standard | NSF-ANSI-49 |
Safety Certification |
Air Cleanliness (ISO 14644) | ISO-Class-5 |
Downflow fpm (m/s) | 60 fpm (0.30 m/s) |
Fumigation: per NIH/NSF Procedures | True |
Inflow fpm (m/s) | 105 fpm (0.53 m/s) |
Protection | Product, Personnel, Environmental |
Airflow Monitor | Pressure |
Control System | AeroMax |
Est. Shipping Weight lbs (kg) | 515 lbs. / 234 kg. |
Net Weight lbs (kg) | 465 lbs. / 211 kg. |
Blower Contact Wires | Optional |
Closure Panels | Optional Rear Closure Panels for Seismic Brackets |
Cord Pass Through | Standard Right, Optional Left |
Double Exhaust HEPA Filter | N/A |
Gas Supply Interlock with Blower | N/A |
Glass Sidewalls | N/A |
IV Bar with 6 Hooks | Optional |
Magnifying Glass in Window | N/A |
Motorized Base Stand | Optional as Separate Accessory |
Motorized Window | N/A |
Other Built-in Supply Filter Option(s) | N/A |
Outlet(s) | Standard, two backwall |
Plumbing | Optional 3/8" Soft Copper, 3/8" Black Pipe (Gas Only), or 1/2" Rigid Copper |
Remote Service Valves | N/A |
Seismic Brackets or Studs | Optional Rear or Floor Mount Seismic Brackets |
Service Couplings (3/8-inch NPT) | Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Three Each Side Wall Optional |
Service Valves (3/8-inch NPT) | One Valve on Right Side Wall is Standard, Maximum of Three Each Side Wall Optional |
Side Panels | Optional with Plumbing out Bottom, Top or Back |
Smooth Interior | N/A |
Ultraviolet (UV) Light | Optional |
Window Edge Protector | Optional |
Access Opening Glass Type | Tempered |
Armrest | Standard Plastic with Optional Stainless Steel |
Cabinet Construction | All welded stainless steel 16/18 GA, Type 304 pressure tight design |
Casters | N/A |
Decontamination Seal-able Window | N/A |
Diffuser | Metal, non-flammable |
Drain Valve Location | Front right |
Exhaust Filter | 6-inch (152 mm) 99.99% Efficiency on 0.3 microns |
Front & Control Panel Material | Painted Steel |
HEPA Filter Seal Type | HEPEX Zero Leak Neoprene Seal, Spring-loaded |
Lighting | LED |
Main Cabinet Wrap | Single Piece Stainless Steel Side and Back Wall Construction |
Motor(s) | 3/4 HP DC ECM |
Plenum Type | HEPEX |
Pre-filter | N/A |
Style | Bench top, optional base stand |
Supply Filter | 3-inch (76mm) 99.99% Efficiency on 0.3 microns |
Viewing Window Inches (mm) | 21 (533) open to fully closed |
Work Access Opening(s) | 8, 10-inch (203, 254 mm) |
Work Surface | One-Piece Dished Stainless Steel with Prop-Up Rod |
Work Zone Wrap | Single Piece Stainless Steel Side and Back Wall Construction |
Data Output Features | RS-232 |
Remote Alarm Terminals | Standard |
Est. Shipping Depth Inches (mm) | 43 (1092) |
Est. Shipping Height Inches (mm) | 75 (1905) |
Est. Shipping Width Inches (mm) | 72 (1829) |
Exterior Depth Inches (mm) | 32 1/8 (817) |
Exterior Depth with Armrest Removed Inches (mm) | 31 7/16 (799) |
Exterior Height (Minimum for Transport) Inches (mm) | 59 (1499) |
Exterior Height Inches (mm) | 60 7/8 (1546) |
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) | 87.375 (2219) |
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) | 93.375 (2371) |
Exterior Width Inches (mm) | 65 5/8 (1669) |
Nominal Width Feet (Meters) | 5 ft. (1.5m) |
Useable Work Tray Area Depth Inches (mm) | 20 7/8 (530) |
Useable Work Tray Area Width Inches (mm) | 57 7/8 (1470) |
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) | 25 3/4 (654) |
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) | N/A |
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) | N/A |
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) | Inquire |
Work Area Height Inches (mm) | 28 1/2 (724) |
Work Area Width Inches (mm) | 46 3/8 (1178) |
Blower/Lights Amps [10-inch (254 mm) Access Opening] | 4.5 |
Blower/Lights Amps [12-inch (305 mm) Access Opening] | |
Blower/Lights Amps [14-inch (356mm) Access Opening] | |
Blower/Lights Amps [8-inch (203 mm) Access Opening] | 4.1 |
Electrical Configuration | 115V60Hz |
Junction Box | Optional |
Outlet Amps | 3 |
Power Cord | Single 12-foot (3.7 m) 12 GA-3 Wire, 20A Std., 15A Optional |
Power Cord Length Foot (Meter) | 12 (3.7) |
Rated Amps | 14 |
Light Intensity fc (Lux) | 90-120 (968-1291) |
Reach into workzone Inches (mm) | 6 (152) |
Sound Pressure Level per ISO 4871 | ≤ 58 |
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) | 531 (902) |
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) | 451-676 (766-1149) |
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) | N/A |
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) | N/A |
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) | N/A |
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) | N/A |
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) | 445 (756) |
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) | 365-590 (621-1003) |
Bag In Bag Out | N/A |
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) | 1768 |
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) | N/A |
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) | N/A |
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) | 1611 |
Heat Rejected Vented (BTU/Hour) | 198 |
Other Built-in Exhaust Option(s) | N/A |
Plant Duct Static Pressure Inches (mm) | 0.05-0.1"/1.27-2.54mm H2O |
Australian Test Method | N/A |
Performance Standard | NSF-ANSI-49 |
Safety Certification |
Air Cleanliness (ISO 14644) | ISO-Class-5 |
Downflow fpm (m/s) | 60 fpm (0.30 m/s) |
Fumigation: per NIH/NSF Procedures | True |
Inflow fpm (m/s) | 105 fpm (0.53 m/s) |
Protection | Product, Personnel, Environmental |
Airflow Monitor | Pressure |
Control System | AeroMax |
Est. Shipping Weight lbs (kg) | 600 lbs. / 272 kg. |
Net Weight lbs (kg) | 550 lbs. / 249 kg. |
Blower Contact Wires | Optional |
Closure Panels | Optional Rear Closure Panels for Seismic Brackets |
Cord Pass Through | Standard Right, Optional Left |
Double Exhaust HEPA Filter | N/A |
Gas Supply Interlock with Blower | N/A |
Glass Sidewalls | N/A |
IV Bar with 6 Hooks | Optional |
Magnifying Glass in Window | N/A |
Motorized Base Stand | Optional as Separate Accessory |
Motorized Window | N/A |
Other Built-in Supply Filter Option(s) | N/A |
Outlet(s) | Standard, two backwall |
Plumbing | Optional 3/8" Soft Copper, 3/8" Black Pipe (Gas Only), or 1/2" Rigid Copper |
Remote Service Valves | N/A |
Seismic Brackets or Studs | Optional Rear or Floor Mount Seismic Brackets |
Service Couplings (3/8-inch NPT) | Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Three Each Side Wall Optional |
Service Valves (3/8-inch NPT) | One Valve on Right Side Wall is Standard, Maximum of Three Each Side Wall Optional |
Side Panels | Optional with Plumbing out Bottom, Top or Back |
Smooth Interior | N/A |
Ultraviolet (UV) Light | Optional |
Window Edge Protector | Optional |
Access Opening Glass Type | Tempered Glass |
Armrest | Standard Plastic with Optional Stainless Steel |
Cabinet Construction | All welded stainless steel 16/18 GA, Type 304 pressure tight design |
Casters | N/A |
Decontamination Seal-able Window | N/A |
Diffuser | Metal, non-flammable |
Drain Valve Location | Front right |
Exhaust Filter | 6-inch (152 mm) 99.99% Efficiency on 0.3 microns |
Front & Control Panel Material | Painted Steel |
HEPA Filter Seal Type | HEPEX Zero Leak Neoprene Seal, Spring-loaded |
Lighting | LED |
Main Cabinet Wrap | Single Piece Stainless Steel Side and Back Wall Construction |
Motor(s) | 3/4 HP DC ECM |
Plenum Type | HEPEX |
Pre-filter | N/A |
Style | Bench top, optional base stand |
Supply Filter | 3-inch (76mm) 99.99% Efficiency on 0.3 microns |
Viewing Window Inches (mm) | 21 (533) open to fully closed |
Work Access Opening(s) | 10-inch (254 mm) |
Work Surface | One-Piece Dished Stainless Steel with Prop-Up Rod |
Work Zone Wrap | Single Piece Stainless Steel Side and Back Wall Construction |
Data Output Features | RS-232 |
Remote Alarm Terminals | Standard |
Est. Shipping Depth Inches (mm) | 43 (1092) |
Est. Shipping Height Inches (mm) | 75 (1905) |
Est. Shipping Width Inches (mm) | 72 (1829) |
Exterior Depth Inches (mm) | 32 1/8 (817) |
Exterior Depth with Armrest Removed Inches (mm) | 31 7/16 (799) |
Exterior Height (Minimum for Transport) Inches (mm) | 59 (1499) |
Exterior Height Inches (mm) | 60 7/8 (1546) |
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) | 88 3/8 (2245) |
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) | 94 3/8 (2397) |
Exterior Width Inches (mm) | 65 5/8 (1669) |
Nominal Width Feet (Meters) | 5 ft. (1.5m) |
Useable Work Tray Area Depth Inches (mm) | 20 7/8 (530) |
Useable Work Tray Area Width Inches (mm) | 57 7/8 (1470) |
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) | 25 3/4 (654) |
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) | N/A |
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) | N/A |
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) | N/A |
Work Area Height Inches (mm) | 28 1/2 (724) |
Work Area Width Inches (mm) | 46 3/8 (1178) |
Blower/Lights Amps [10-inch (254 mm) Access Opening] | 4.5 |
Blower/Lights Amps [12-inch (305 mm) Access Opening] | |
Blower/Lights Amps [14-inch (356mm) Access Opening] | |
Blower/Lights Amps [8-inch (203 mm) Access Opening] | |
Electrical Configuration | 230V5060Hz |
Junction Box | Optional |
Outlet Amps | 3 |
Power Cord | Single 12-foot (3.7 m) 14 GA-3 Wire, 15A Std. |
Power Cord Length Foot (Meter) | 12 (3.7) |
Rated Amps | 11 |
Light Intensity fc (Lux) | 90-120 (968-1291) |
Reach into workzone Inches (mm) | 6 (152) |
Sound Pressure Level per ISO 4871 | ≤ 58 |
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) | 531 (902) |
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) | 451-676 (766-1149) |
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) | N/A |
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) | N/A |
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) | N/A |
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) | N/A |
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) | N/A |
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) | N/A |
Bag In Bag Out | N/A |
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) | 1768 |
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) | N/A |
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) | N/A |
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) | N/A |
Heat Rejected Vented (BTU/Hour) | 198 |
Other Built-in Exhaust Option(s) | N/A |
Plant Duct Static Pressure Inches (mm) | 0.05-0.1"/1.27-2.54mm H2O |
Australian Test Method | N/A |
Performance Standard | NSF-ANSI-49 |
Safety Certification |
Air Cleanliness (ISO 14644) | ISO-Class-5 |
Downflow fpm (m/s) | 60 fpm (0.30 m/s) |
Fumigation: per NIH/NSF Procedures | True |
Inflow fpm (m/s) | 105 fpm (0.53 m/s) |
Protection | Product, Personnel, Environmental |
Airflow Monitor | Pressure |
Control System | AeroMax |
Est. Shipping Weight lbs (kg) | 600 lbs. / 272 kg. |
Net Weight lbs (kg) | 550 lbs. / 249 kg. |
Blower Contact Wires | Optional |
Closure Panels | Optional Rear Closure Panels for Seismic Brackets |
Cord Pass Through | Standard Right, Optional Left |
Double Exhaust HEPA Filter | N/A |
Gas Supply Interlock with Blower | N/A |
Glass Sidewalls | N/A |
IV Bar with 6 Hooks | Optional |
Magnifying Glass in Window | N/A |
Motorized Base Stand | Optional as Separate Accessory |
Motorized Window | N/A |
Other Built-in Supply Filter Option(s) | N/A |
Outlet(s) | Standard, two backwall |
Plumbing | Optional 3/8" Soft Copper, 3/8" Black Pipe (Gas Only), or 1/2" Rigid Copper |
Remote Service Valves | N/A |
Seismic Brackets or Studs | Optional Rear or Floor Mount Seismic Brackets |
Service Couplings (3/8-inch NPT) | Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Three Each Side Wall Optional |
Service Valves (3/8-inch NPT) | One Valve on Right Side Wall is Standard, Maximum of Three Each Side Wall Optional |
Side Panels | Optional with Plumbing out Bottom, Top or Back |
Smooth Interior | N/A |
Ultraviolet (UV) Light | Optional |
Window Edge Protector | Optional |
Access Opening Glass Type | Tempered |
Armrest | Standard Plastic with Optional Stainless Steel |
Cabinet Construction | All welded stainless steel 16/18 GA, Type 304 pressure tight design |
Casters | N/A |
Decontamination Seal-able Window | N/A |
Diffuser | Metal, non-flammable |
Drain Valve Location | Front right |
Exhaust Filter | 6-inch (152 mm) 99.99% Efficiency on 0.3 microns |
Front & Control Panel Material | Painted Steel |
HEPA Filter Seal Type | HEPEX Zero Leak Neoprene Seal, Spring-loaded |
Lighting | LED |
Main Cabinet Wrap | Single Piece Stainless Steel Side and Back Wall Construction |
Motor(s) | 3/4 HP DC ECM |
Plenum Type | HEPEX |
Pre-filter | N/A |
Style | Bench top, optional base stand |
Supply Filter | 3-inch (76mm) 99.99% Efficiency on 0.3 microns |
Viewing Window Inches (mm) | 21 (533) open to fully closed |
Work Access Opening(s) | 8, 10-inch (203, 254 mm) |
Work Surface | One-Piece Dished Stainless Steel with Prop-Up Rod |
Work Zone Wrap | Single Piece Stainless Steel Side and Back Wall Construction |
Data Output Features | RS-232 |
Remote Alarm Terminals | Standard |
Est. Shipping Depth Inches (mm) | 43 (1092) |
Est. Shipping Height Inches (mm) | 75 (1905) |
Est. Shipping Width Inches (mm) | 84 (2137) |
Exterior Depth Inches (mm) | 32 1/8 (817) |
Exterior Depth with Armrest Removed Inches (mm) | 31 7/16 (799) |
Exterior Height (Minimum for Transport) Inches (mm) | 59 (1499) |
Exterior Height Inches (mm) | 60 7/8 (1546) |
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) | 87.375 (2219) |
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) | 93.375 (2371) |
Exterior Width Inches (mm) | 77 5/8 (1972) |
Nominal Width Feet (Meters) | 6 ft. (1.8m) |
Useable Work Tray Area Depth Inches (mm) | 20 7/8 (530) |
Useable Work Tray Area Width Inches (mm) | 69 7/8 (1775) |
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) | 25 3/4 (654) |
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) | N/A |
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) | N/A |
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) | Inquire |
Work Area Height Inches (mm) | 28 1/2 (724) |
Work Area Width Inches (mm) | 70 3/8 (1788) |
Blower/Lights Amps [10-inch (254 mm) Access Opening] | 4.8 |
Blower/Lights Amps [12-inch (305 mm) Access Opening] | |
Blower/Lights Amps [14-inch (356mm) Access Opening] | |
Blower/Lights Amps [8-inch (203 mm) Access Opening] | 4.5 |
Electrical Configuration | 115V60Hz |
Junction Box | Optional |
Outlet Amps | 3 |
Power Cord | Single 12-foot (3.7 m) 12 GA-3 Wire, 20A Std., 15A Optional |
Power Cord Length Foot (Meter) | 12 (3.7) |
Rated Amps | 14 |
Light Intensity fc (Lux) | 90-120 (968-1291) |
Reach into workzone Inches (mm) | 6 (152) |
Sound Pressure Level per ISO 4871 | ≤ 60 dba |
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) | 634 (1077) |
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) | 538-763 (915-1297) |
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) | N/A |
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) | N/A |
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) | N/A |
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) | N/A |
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) | 532 (904) |
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) | 436-661 (741-1124) |
Bag In Bag Out | N/A |
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) | 1884 |
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) | N/A |
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) | N/A |
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) | 1768 |
Heat Rejected Vented (BTU/Hour) | 198 |
Other Built-in Exhaust Option(s) | N/A |
Plant Duct Static Pressure Inches (mm) | 0.05-0.1"/1.27-2.54mm H2O |
Australian Test Method | N/A |
Performance Standard | NSF-ANSI-49 |
Safety Certification |
Air Cleanliness (ISO 14644) | ISO-Class-5 |
Downflow fpm (m/s) | 60 fpm (0.30 m/s) |
Fumigation: per NIH/NSF Procedures | True |
Inflow fpm (m/s) | 105 fpm (0.53 m/s) |
Protection | Product, Personnel, Environmental |
Airflow Monitor | Pressure |
Control System | AeroMax |
Est. Shipping Weight lbs (kg) | 670 lbs. / 304 kg. |
Net Weight lbs (kg) | 620 lbs. / 281 kg. |
Blower Contact Wires | Optional |
Closure Panels | Optional Rear Closure Panels for Seismic Brackets |
Cord Pass Through | Standard Right, Optional Left |
Double Exhaust HEPA Filter | N/A |
Gas Supply Interlock with Blower | N/A |
Glass Sidewalls | N/A |
IV Bar with 6 Hooks | Optional |
Magnifying Glass in Window | N/A |
Motorized Base Stand | Optional as Separate Accessory |
Motorized Window | N/A |
Other Built-in Supply Filter Option(s) | N/A |
Outlet(s) | Standard, two backwall |
Plumbing | Optional 3/8" Soft Copper, 3/8" Black Pipe (Gas Only), or 1/2" Rigid Copper |
Remote Service Valves | N/A |
Seismic Brackets or Studs | Optional Rear or Floor Mount Seismic Brackets |
Service Couplings (3/8-inch NPT) | Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Three Each Side Wall Optional |
Service Valves (3/8-inch NPT) | One Valve on Right Side Wall is Standard, Maximum of Three Each Side Wall Optional |
Side Panels | Optional with Plumbing out Bottom, Top or Back |
Smooth Interior | N/A |
Ultraviolet (UV) Light | Optional |
Window Edge Protector | Optional |
Access Opening Glass Type | Safety Plate |
Armrest | Standard Plastic with Optional Stainless Steel |
Cabinet Construction | All welded stainless steel 16/18 GA, Type 304 pressure tight design |
Casters | N/A |
Decontamination Seal-able Window | N/A |
Diffuser | Metal, non-flammable |
Drain Valve Location | Front right |
Exhaust Filter | 6-inch (152 mm) 99.99% Efficiency on 0.3 microns |
Front & Control Panel Material | Painted Steel |
HEPA Filter Seal Type | HEPEX Zero Leak Neoprene Seal, Spring-loaded |
Lighting | LED |
Main Cabinet Wrap | Single Piece Stainless Steel Side and Back Wall Construction |
Motor(s) | 3/4 HP DC ECM |
Plenum Type | HEPEX |
Pre-filter | N/A |
Style | Bench top, optional base stand |
Supply Filter | 3-inch (76mm) 99.99% Efficiency on 0.3 microns |
Viewing Window Inches (mm) | 21 (533) open to fully closed |
Work Access Opening(s) | 10-inch (254 mm) |
Work Surface | One-Piece Dished Stainless Steel with Prop-Up Rod |
Work Zone Wrap | Single Piece Stainless Steel Side and Back Wall Construction |
Data Output Features | RS-232 |
Remote Alarm Terminals | Standard |
Est. Shipping Depth Inches (mm) | 43 (1092) |
Est. Shipping Height Inches (mm) | 75 (1905) |
Est. Shipping Width Inches (mm) | 84 (2137) |
Exterior Depth Inches (mm) | 32 1/8 (817) |
Exterior Depth with Armrest Removed Inches (mm) | 31 7/16 (799) |
Exterior Height (Minimum for Transport) Inches (mm) | 59 (1499) |
Exterior Height Inches (mm) | 60 7/8 (1546) |
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) | 88 3/8 (2245) |
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) | 94 3/8 (2397) |
Exterior Width Inches (mm) | 77 5/8 (1972) |
Nominal Width Feet (Meters) | 6 ft. (1.8m) |
Useable Work Tray Area Depth Inches (mm) | 20 7/8 (530) |
Useable Work Tray Area Width Inches (mm) | 69 7/8 (1775) |
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) | 25 3/4 (654) |
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) | N/A |
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) | N/A |
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) | N/A |
Work Area Height Inches (mm) | 28 1/2 (724) |
Work Area Width Inches (mm) | 70 3/8 (1788) |
Blower/Lights Amps [10-inch (254 mm) Access Opening] | 4.8 |
Blower/Lights Amps [12-inch (305 mm) Access Opening] | |
Blower/Lights Amps [14-inch (356mm) Access Opening] | |
Blower/Lights Amps [8-inch (203 mm) Access Opening] | |
Electrical Configuration | 230V5060Hz |
Junction Box | Optional |
Outlet Amps | 3 |
Power Cord | Single 12-foot (3.7 m) 14 GA-3 Wire, 15A Std. |
Power Cord Length Foot (Meter) | 12 (3.7) |
Rated Amps | 11 |
Light Intensity fc (Lux) | 90-120 (968-1291) |
Reach into workzone Inches (mm) | 6 (152) |
Sound Pressure Level per ISO 4871 | ≤ 60 dba |
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) | 634 (1077) |
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) | 538-763 (915-1297) |
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) | N/A |
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) | N/A |
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) | N/A |
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) | N/A |
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) | N/A |
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) | N/A |
Bag In Bag Out | N/A |
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) | 1884 |
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) | N/A |
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) | N/A |
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) | N/A |
Heat Rejected Vented (BTU/Hour) | 198 |
Other Built-in Exhaust Option(s) | N/A |
Plant Duct Static Pressure Inches (mm) | 0.05-0.1"/1.27-2.54mm H2O |
Australian Test Method | N/A |
Performance Standard | NSF-ANSI-49 |
Safety Certification |
Air Cleanliness (ISO 14644) | ISO-Class-5 |
Downflow fpm (m/s) | 60 fpm (0.30 m/s) |
Fumigation: per NIH/NSF Procedures | True |
Inflow fpm (m/s) | 105 fpm (0.53 m/s) |
Protection | Product, Personnel, Environmental |
Airflow Monitor | Pressure |
Control System | AeroMax |
Est. Shipping Weight lbs (kg) | 670 lbs. / 304 kg. |
Net Weight lbs (kg) | 620 lbs. / 281 kg. |
Review
Resources
Manuals
Drawings
- NU-540-500E 1.5m 230V Class II Biosafety Cabinet Cut Sheet
- 6-foot (1.8m) Biosafety Cabinet with Exhaust Canopy Cut Sheet
- NU-540-500 5FT 115V Class II, Type A2 Biosafety Cabinet - Engineering Drawing
- NU-540-300, 3-ft 115V Class II Biosafety Cabinet Drawing
- NU-540-400 4FT 115V Class II, Type A2 Biosafety Cabinet - Engineering Drawing
- NU-540 1.8m 230V Class II Biosafety Cabinet Cut Sheet
- NU-540 6-ft 115V Class II Biosafety Cabinet Cut Sheet
- NU-540-300E 0.9m 230V Class II, Type A2 Biosafety Cabinet - Engineering Drawing
- NU-540 1.2m 230V Class II Biosafety Cabinet Cut Sheet
Videos
Specifications
BIM Revit
Request Your Quote for a NU-540
Thank you for completing the form.
We will be in touch. If you have any urgent questions, please reach out at 763-553-1270.