LabGard ES NU-540 Class II Type A2 Biosafety Cabinet

The NU-540 integrates a powerful DC ECM motor with flexible plenum into a robust steel structure to provide long-term, cost effective containment configured for basic research and clinical applications.
Available for

Overview

The NU-540 features a DC ECM motor to economize energy while distributing laminar airflow through a flexible plenum and offering enough power to overcome HEPA filter loading and minimize filter changes. This design provides the user with a work zone whose side and back walls are constructed from a single piece of stainless steel for enhanced containment and easy cleanability. Fluorescent lighting illuminates the procedure inside the cabinet while a dished work tray traps liquid spills and a cord-pass through in the side wall facilitates the use of small electrical devices in the work area. Users easily monitor cabinet performance through the Aeromax™ control system that displays the pressure in the cabinet’s internal airflow plenum. The NU-540 is configured to meet the needs of most clinical and research applications, offering containment that meets the NSF/ANSI 49 standard that is followed in most of the Americas.

AeroMax Control System

The AeroMax control system visualizes airflow plenum pressure through a series of multicolored lights and activates both an audible and visual alarm whenever cabinet performance departs from normal parameters.

AeroMax Electronic Control System for Lab Equipment

Ultra High Efficiency Motor

A single DC ECM motor with a precision-engineered forward curved fan powers airflow through the biosafety cabinet. The ultra-high efficiency motor lowers energy costs and reduces noise pollution but is powerful enough to extend filter life. The one motor design allows for easy certification and airflow balancing. In addition, it provides enough power to compensate for HEPA filter loading, reducing filter changes and lowering the total ownership cost.

Ultra high efficiency motor for lab equipment

HEPEX Zero Leak Airflow System

Our signature flexible plenum design complements the ultra-high efficiency motor to uniformly distribute the downflow air across the supply HEPA filter into the work zone in a laminar or unidirectional pattern. The flexible plenum insulates the transmission path of any vibration and noise produced by the motor blower protecting sensitive cells and reducing noise pollution. The HEPEX material is tear and abrasion-resistant, flame retardant, and impermeable to gases, fluids, and dust reducing contamination risks making it the perfect solution for biomedical/microbiological and hazardous drug compounding work. All filter seals are kept under negative pressure. In the event of a potential leak, air will recirculate back through the motor blower and into the plenum.

HEPEX Zero Leak Airflow System for Biosafety Cabinets

Monolithic Construction

At the heart of any NuAire biosafety cabinet is its construction. The NuAire design centers on the use of high-quality stainless steel and seam welding to eliminate leak risks that come with the use of multi-piece shells put together with gaskets, sealants, and rivets. The NuAire BSC uses a coved stainless steel interior inserted into a larger wrap that makes up the cabinet walls. The top and bottom catch tray is seam welded into place, creating a monolithic leak-free cabinet shell designed to provide long-lasting maximum safety.

Biosafety Cabinet Monolithic Construction

Specifications

NU-540 Class II, Type A2 Biosafety Cabinet
Blower Contact Wires Optional
Closure Panels Optional Rear Closure Panels for Seismic Brackets
Cord Pass Through Standard Right, Optional Left
Double Exhaust HEPA Filter N/A
Gas Supply Interlock with Blower N/A
Glass Sidewalls N/A
IV Bar with 6 Hooks Optional
Magnifying Glass in Window N/A
Motorized Base Stand Optional as Separate Accessory
Motorized Window N/A
Other Built-in Supply Filter Option(s) N/A
Outlet(s) Standard, two backwall
Plumbing Optional 3/8" Soft Copper, 3/8" Black Pipe (Gas Only), or 1/2" Rigid Copper
Remote Service Valves N/A
Seismic Brackets or Studs Optional Rear or Floor Mount Seismic Brackets
Service Couplings (3/8-inch NPT) Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Three Each Side Wall Optional
Service Valves (3/8-inch NPT) One Valve on Right Side Wall is Standard, Maximum of Three Each Side Wall Optional
Side Panels Optional with Plumbing out Bottom, Top or Back
Smooth Interior N/A
Ultraviolet (UV) Light Optional
Window Edge Protector Optional
Access Opening Glass Type Tempered
Armrest Standard Plastic with Optional Stainless Steel
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Casters N/A
Decontamination Seal-able Window N/A
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 6-inch (152 mm) 99.99% Efficiency on 0.3 microns
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Single Piece Stainless Steel Side and Back Wall Construction
Motor(s) 1/2 HP DC ECM
Plenum Type HEPEX
Pre-filter N/A
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.99% Efficiency on 0.3 microns
Viewing Window Inches (mm) 21 (533) open to fully closed
Work Access Opening(s) 8, 10-inch (203, 254 mm)
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 43 (1092)
Est. Shipping Height Inches (mm) 71 (1803)
Est. Shipping Width Inches (mm) 46 (1168)
Exterior Depth Inches (mm) 32 1/8 (817)
Exterior Depth with Armrest Removed Inches (mm) 31 7/16 (799)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 87.375 (2219)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 93.375 (2371)
Exterior Width Inches (mm) 41 5/8 (1057)
Nominal Width Feet (Meters) 3 ft. (0.9m)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 33 7/8 (860)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 25 3/4 (654)
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) Inquire
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 34 3/8 (873)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 2.3
Blower/Lights Amps [12-inch (305 mm) Access Opening]
Blower/Lights Amps [14-inch (356mm) Access Opening]
Blower/Lights Amps [8-inch (203 mm) Access Opening] 2.1
Electrical Configuration 115V60Hz
Junction Box Optional
Outlet Amps 3
Power Cord Single 12-foot (3.7m) 14 GA - 3 Wire, 15A
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 10
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 ≤ 55dba
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 320 (544)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 276-501 (649-851)
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 269 (457)
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 255-450 (383-765)
Bag In Bag Out N/A
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 903
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) 826
Heat Rejected Vented (BTU/Hour) 120
Other Built-in Exhaust Option(s) N/A
Plant Duct Static Pressure Inches (mm) 0.05-0.1"/1.27-2.54mm H2O
Australian Test Method N/A
Performance Standard NSF-ANSI-49
Safety Certification
Air Cleanliness (ISO 14644) ISO-Class-5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor Pressure
Control System AeroMax
Est. Shipping Weight lbs (kg) 450 lbs. / 204 kg.
Net Weight lbs (kg) 400 lbs. /181 kg.
Blower Contact Wires Optional
Closure Panels Optional Rear Closure Panels for Seismic Brackets
Cord Pass Through Standard Right, Optional Left
Double Exhaust HEPA Filter N/A
Gas Supply Interlock with Blower N/A
Glass Sidewalls N/A
IV Bar with 6 Hooks Optional
Magnifying Glass in Window N/A
Motorized Base Stand Optional as Separate Accessory
Motorized Window N/A
Other Built-in Supply Filter Option(s) N/A
Outlet(s) Standard, two backwall
Plumbing Optional 3/8" Soft Copper, 3/8" Black Pipe (Gas Only), or 1/2" Rigid Copper
Remote Service Valves N/A
Seismic Brackets or Studs Optional Rear or Floor Mount Seismic Brackets
Service Couplings (3/8-inch NPT) Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Three Each Side Wall Optional
Service Valves (3/8-inch NPT) One Valve on Right Side Wall is Standard, Maximum of Three Each Side Wall Optional
Side Panels Optional with Plumbing out Bottom, Top or Back
Smooth Interior N/A
Ultraviolet (UV) Light Optional
Window Edge Protector Optional
Access Opening Glass Type Tempered Glass
Armrest Standard Plastic with Optional Stainless Steel
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Casters N/A
Decontamination Seal-able Window N/A
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 6-inch (152 mm) 99.99% Efficiency on 0.3 microns
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Single Piece Stainless Steel Side and Back Wall Construction
Motor(s) 1/2 HP DC ECM
Plenum Type HEPEX
Pre-filter N/A
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.99% Efficiency on 0.3 microns
Viewing Window Inches (mm) 21 (533) open to fully closed
Work Access Opening(s) 10-inch (254 mm)
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 71 (1803)
Est. Shipping Height Inches (mm) 43 (1092)
Est. Shipping Width Inches (mm) 46 (1168)
Exterior Depth Inches (mm) 32 1/8 (817)
Exterior Depth with Armrest Removed Inches (mm) 31 7/16 (799)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 88 3/8 (2245)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 94 3/8 (2397)
Exterior Width Inches (mm) 41 5/8 (1057)
Nominal Width Feet (Meters) 3 ft. (0.9m)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 33 7/8 (860)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 25 3/4 (654)
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) N/A
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 34 3/8 (873)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 2.3
Blower/Lights Amps [12-inch (305 mm) Access Opening]
Blower/Lights Amps [14-inch (356mm) Access Opening]
Blower/Lights Amps [8-inch (203 mm) Access Opening]
Electrical Configuration 230V5060Hz
Junction Box Optional
Outlet Amps 3
Power Cord Single 12-foot (3.7m) 14 GA - 3 Wire, 15A
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 8
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 ≤ 55dba
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 320 (544)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 276-501 (649-851)
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
Bag In Bag Out N/A
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 903
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) N/A
Heat Rejected Vented (BTU/Hour) 120
Other Built-in Exhaust Option(s) N/A
Plant Duct Static Pressure Inches (mm) 0.05-0.1"/1.27-2.54mm H2O
Australian Test Method N/A
Performance Standard NSF-ANSI-49
Safety Certification
Air Cleanliness (ISO 14644) ISO-Class-5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor Pressure
Control System AeroMax
Est. Shipping Weight lbs (kg) 450 lbs. / 204 kg.
Net Weight lbs (kg) 400 lbs. /181 kg.
Blower Contact Wires Optional
Closure Panels Optional Rear Closure Panels for Seismic Brackets
Cord Pass Through Standard Right, Optional Left
Double Exhaust HEPA Filter N/A
Gas Supply Interlock with Blower N/A
Glass Sidewalls N/A
IV Bar with 6 Hooks Optional
Magnifying Glass in Window N/A
Motorized Base Stand Optional as Separate Accessory
Motorized Window N/A
Other Built-in Supply Filter Option(s) N/A
Outlet(s) Standard, two backwall
Plumbing Optional 3/8" Soft Copper, 3/8" Black Pipe (Gas Only), or 1/2" Rigid Copper
Remote Service Valves N/A
Seismic Brackets or Studs Optional Rear or Floor Mount Seismic Brackets
Service Couplings (3/8-inch NPT) Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Three Each Side Wall Optional
Service Valves (3/8-inch NPT) One Valve on Right Side Wall is Standard, Maximum of Three Each Side Wall Optional
Side Panels Optional with Plumbing out Bottom, Top or Back
Smooth Interior N/A
Ultraviolet (UV) Light Optional
Window Edge Protector Optional
Access Opening Glass Type Tempered
Armrest Standard Plastic with Optional Stainless Steel
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Casters N/A
Decontamination Seal-able Window N/A
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 6-inch (152 mm) 99.99% Efficiency on 0.3 microns
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Single Piece Stainless Steel Side and Back Wall Construction
Motor(s) 1/2 HP DC ECM
Plenum Type HEPEX
Pre-filter N/A
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.99% Efficiency on 0.3 microns
Viewing Window Inches (mm) 21 (533) open to fully closed
Work Access Opening(s) 8, 10-inch (203, 254 mm)
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 43 (1092)
Est. Shipping Height Inches (mm) 71 (1803)
Est. Shipping Width Inches (mm) 59 (1499)
Exterior Depth Inches (mm) 32 1/8 (817)
Exterior Depth with Armrest Removed Inches (mm) 31 7/16 (799)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 87.375 (2219)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 93.375 (2371)
Exterior Width Inches (mm) 53 5/8 (1362)
Nominal Width Feet (Meters) 4 ft. (1.2m)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 45 7/8 (1165)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 25 3/4 (654)
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) Inquire
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 46 3/8 (1178)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 2.9
Blower/Lights Amps [12-inch (305 mm) Access Opening]
Blower/Lights Amps [14-inch (356mm) Access Opening]
Blower/Lights Amps [8-inch (203 mm) Access Opening] 2.6
Electrical Configuration 115V60Hz
Junction Box Optional
Outlet Amps 3
Power Cord Single 12-foot (3.7 m) 14 GA - 3 Wire, 15A
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 12
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 ≤ 56 dba
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 426 (724)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 363-588 (617-1000)
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 359 (610)
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 295-520 (502-884)
Bag In Bag Out N/A
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 1140
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) 1020
Heat Rejected Vented (BTU/Hour) 157
Other Built-in Exhaust Option(s) N/A
Plant Duct Static Pressure Inches (mm) 0.05-0.1"/1.27-2.54mm H2O
Australian Test Method N/A
Performance Standard NSF-ANSI-49
Safety Certification
Air Cleanliness (ISO 14644) ISO-Class-5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor Pressure
Control System AeroMax
Est. Shipping Weight lbs (kg) 515 lbs. / 234 kg.
Net Weight lbs (kg) 465 lbs. / 211 kg.
Blower Contact Wires Optional
Closure Panels Optional Rear Closure Panels for Seismic Brackets
Cord Pass Through Standard Right, Optional Left
Double Exhaust HEPA Filter N/A
Gas Supply Interlock with Blower N/A
Glass Sidewalls N/A
IV Bar with 6 Hooks Optional
Magnifying Glass in Window N/A
Motorized Base Stand Optional as Separate Accessory
Motorized Window N/A
Other Built-in Supply Filter Option(s) N/A
Outlet(s) Standard, two backwall
Plumbing Optional 3/8" Soft Copper, 3/8" Black Pipe (Gas Only), or 1/2" Rigid Copper
Remote Service Valves N/A
Seismic Brackets or Studs Optional Rear or Floor Mount Seismic Brackets
Service Couplings (3/8-inch NPT) Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Three Each Side Wall Optional
Service Valves (3/8-inch NPT) One Valve on Right Side Wall is Standard, Maximum of Three Each Side Wall Optional
Side Panels Optional with Plumbing out Bottom, Top or Back
Smooth Interior N/A
Ultraviolet (UV) Light Optional
Window Edge Protector Optional
Access Opening Glass Type Tempered Glass
Armrest Standard Plastic with Optional Stainless Steel
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Casters N/A
Decontamination Seal-able Window N/A
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 6-inch (152 mm) 99.99% Efficiency on 0.3 microns
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Single Piece Stainless Steel Side and Back Wall Construction
Motor(s) 1/2 HP DC ECM
Plenum Type HEPEX
Pre-filter N/A
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.99% Efficiency on 0.3 microns
Viewing Window Inches (mm) 21 (533) open to fully closed
Work Access Opening(s) 10-inch (254 mm)
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 43 (1092)
Est. Shipping Height Inches (mm) 71 (1803)
Est. Shipping Width Inches (mm) 59 (1499)
Exterior Depth Inches (mm) 32 1/8 (817)
Exterior Depth with Armrest Removed Inches (mm) 31 7/16 (799)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 88 3/8 (2245)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 94 3/8 (2397)
Exterior Width Inches (mm) 53 5/8 (1362)
Nominal Width Feet (Meters) 4 ft. (1.2m)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 45 7/8 (1165)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 25 3/4 (654)
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) N/A
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 46 3/8 (1178)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 2.9
Blower/Lights Amps [12-inch (305 mm) Access Opening]
Blower/Lights Amps [14-inch (356mm) Access Opening]
Blower/Lights Amps [8-inch (203 mm) Access Opening]
Electrical Configuration 230V5060Hz
Junction Box Optional
Outlet Amps 3
Power Cord Single 12-foot (3.7 m) 14 GA - 3 Wire, 15A
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 10
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 ≤ 56 dba
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 426 (724)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 363-588 (617-1000)
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
Bag In Bag Out N/A
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 1140
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) N/A
Heat Rejected Vented (BTU/Hour) 157
Other Built-in Exhaust Option(s) N/A
Plant Duct Static Pressure Inches (mm) 0.05-0.1"/1.27-2.54mm H2O
Australian Test Method N/A
Performance Standard NSF-ANSI-49
Safety Certification
Air Cleanliness (ISO 14644) ISO-Class-5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor Pressure
Control System AeroMax
Est. Shipping Weight lbs (kg) 515 lbs. / 234 kg.
Net Weight lbs (kg) 465 lbs. / 211 kg.
Blower Contact Wires Optional
Closure Panels Optional Rear Closure Panels for Seismic Brackets
Cord Pass Through Standard Right, Optional Left
Double Exhaust HEPA Filter N/A
Gas Supply Interlock with Blower N/A
Glass Sidewalls N/A
IV Bar with 6 Hooks Optional
Magnifying Glass in Window N/A
Motorized Base Stand Optional as Separate Accessory
Motorized Window N/A
Other Built-in Supply Filter Option(s) N/A
Outlet(s) Standard, two backwall
Plumbing Optional 3/8" Soft Copper, 3/8" Black Pipe (Gas Only), or 1/2" Rigid Copper
Remote Service Valves N/A
Seismic Brackets or Studs Optional Rear or Floor Mount Seismic Brackets
Service Couplings (3/8-inch NPT) Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Three Each Side Wall Optional
Service Valves (3/8-inch NPT) One Valve on Right Side Wall is Standard, Maximum of Three Each Side Wall Optional
Side Panels Optional with Plumbing out Bottom, Top or Back
Smooth Interior N/A
Ultraviolet (UV) Light Optional
Window Edge Protector Optional
Access Opening Glass Type Tempered
Armrest Standard Plastic with Optional Stainless Steel
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Casters N/A
Decontamination Seal-able Window N/A
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 6-inch (152 mm) 99.99% Efficiency on 0.3 microns
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Single Piece Stainless Steel Side and Back Wall Construction
Motor(s) 3/4 HP DC ECM
Plenum Type HEPEX
Pre-filter N/A
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.99% Efficiency on 0.3 microns
Viewing Window Inches (mm) 21 (533) open to fully closed
Work Access Opening(s) 8, 10-inch (203, 254 mm)
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 43 (1092)
Est. Shipping Height Inches (mm) 75 (1905)
Est. Shipping Width Inches (mm) 72 (1829)
Exterior Depth Inches (mm) 32 1/8 (817)
Exterior Depth with Armrest Removed Inches (mm) 31 7/16 (799)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 87.375 (2219)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 93.375 (2371)
Exterior Width Inches (mm) 65 5/8 (1669)
Nominal Width Feet (Meters) 5 ft. (1.5m)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 57 7/8 (1470)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 25 3/4 (654)
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) Inquire
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 46 3/8 (1178)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 4.5
Blower/Lights Amps [12-inch (305 mm) Access Opening]
Blower/Lights Amps [14-inch (356mm) Access Opening]
Blower/Lights Amps [8-inch (203 mm) Access Opening] 4.1
Electrical Configuration 115V60Hz
Junction Box Optional
Outlet Amps 3
Power Cord Single 12-foot (3.7 m) 12 GA-3 Wire, 20A Std., 15A Optional
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 14
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 ≤ 58
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 531 (902)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 451-676 (766-1149)
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 445 (756)
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 365-590 (621-1003)
Bag In Bag Out N/A
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 1768
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) 1611
Heat Rejected Vented (BTU/Hour) 198
Other Built-in Exhaust Option(s) N/A
Plant Duct Static Pressure Inches (mm) 0.05-0.1"/1.27-2.54mm H2O
Australian Test Method N/A
Performance Standard NSF-ANSI-49
Safety Certification
Air Cleanliness (ISO 14644) ISO-Class-5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor Pressure
Control System AeroMax
Est. Shipping Weight lbs (kg) 600 lbs. / 272 kg.
Net Weight lbs (kg) 550 lbs. / 249 kg.
Blower Contact Wires Optional
Closure Panels Optional Rear Closure Panels for Seismic Brackets
Cord Pass Through Standard Right, Optional Left
Double Exhaust HEPA Filter N/A
Gas Supply Interlock with Blower N/A
Glass Sidewalls N/A
IV Bar with 6 Hooks Optional
Magnifying Glass in Window N/A
Motorized Base Stand Optional as Separate Accessory
Motorized Window N/A
Other Built-in Supply Filter Option(s) N/A
Outlet(s) Standard, two backwall
Plumbing Optional 3/8" Soft Copper, 3/8" Black Pipe (Gas Only), or 1/2" Rigid Copper
Remote Service Valves N/A
Seismic Brackets or Studs Optional Rear or Floor Mount Seismic Brackets
Service Couplings (3/8-inch NPT) Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Three Each Side Wall Optional
Service Valves (3/8-inch NPT) One Valve on Right Side Wall is Standard, Maximum of Three Each Side Wall Optional
Side Panels Optional with Plumbing out Bottom, Top or Back
Smooth Interior N/A
Ultraviolet (UV) Light Optional
Window Edge Protector Optional
Access Opening Glass Type Tempered Glass
Armrest Standard Plastic with Optional Stainless Steel
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Casters N/A
Decontamination Seal-able Window N/A
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 6-inch (152 mm) 99.99% Efficiency on 0.3 microns
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Single Piece Stainless Steel Side and Back Wall Construction
Motor(s) 3/4 HP DC ECM
Plenum Type HEPEX
Pre-filter N/A
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.99% Efficiency on 0.3 microns
Viewing Window Inches (mm) 21 (533) open to fully closed
Work Access Opening(s) 10-inch (254 mm)
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 43 (1092)
Est. Shipping Height Inches (mm) 75 (1905)
Est. Shipping Width Inches (mm) 72 (1829)
Exterior Depth Inches (mm) 32 1/8 (817)
Exterior Depth with Armrest Removed Inches (mm) 31 7/16 (799)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 88 3/8 (2245)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 94 3/8 (2397)
Exterior Width Inches (mm) 65 5/8 (1669)
Nominal Width Feet (Meters) 5 ft. (1.5m)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 57 7/8 (1470)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 25 3/4 (654)
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) N/A
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 46 3/8 (1178)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 4.5
Blower/Lights Amps [12-inch (305 mm) Access Opening]
Blower/Lights Amps [14-inch (356mm) Access Opening]
Blower/Lights Amps [8-inch (203 mm) Access Opening]
Electrical Configuration 230V5060Hz
Junction Box Optional
Outlet Amps 3
Power Cord Single 12-foot (3.7 m) 14 GA-3 Wire, 15A Std.
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 11
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 ≤ 58
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 531 (902)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 451-676 (766-1149)
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
Bag In Bag Out N/A
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 1768
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) N/A
Heat Rejected Vented (BTU/Hour) 198
Other Built-in Exhaust Option(s) N/A
Plant Duct Static Pressure Inches (mm) 0.05-0.1"/1.27-2.54mm H2O
Australian Test Method N/A
Performance Standard NSF-ANSI-49
Safety Certification
Air Cleanliness (ISO 14644) ISO-Class-5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor Pressure
Control System AeroMax
Est. Shipping Weight lbs (kg) 600 lbs. / 272 kg.
Net Weight lbs (kg) 550 lbs. / 249 kg.
Blower Contact Wires Optional
Closure Panels Optional Rear Closure Panels for Seismic Brackets
Cord Pass Through Standard Right, Optional Left
Double Exhaust HEPA Filter N/A
Gas Supply Interlock with Blower N/A
Glass Sidewalls N/A
IV Bar with 6 Hooks Optional
Magnifying Glass in Window N/A
Motorized Base Stand Optional as Separate Accessory
Motorized Window N/A
Other Built-in Supply Filter Option(s) N/A
Outlet(s) Standard, two backwall
Plumbing Optional 3/8" Soft Copper, 3/8" Black Pipe (Gas Only), or 1/2" Rigid Copper
Remote Service Valves N/A
Seismic Brackets or Studs Optional Rear or Floor Mount Seismic Brackets
Service Couplings (3/8-inch NPT) Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Three Each Side Wall Optional
Service Valves (3/8-inch NPT) One Valve on Right Side Wall is Standard, Maximum of Three Each Side Wall Optional
Side Panels Optional with Plumbing out Bottom, Top or Back
Smooth Interior N/A
Ultraviolet (UV) Light Optional
Window Edge Protector Optional
Access Opening Glass Type Tempered
Armrest Standard Plastic with Optional Stainless Steel
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Casters N/A
Decontamination Seal-able Window N/A
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 6-inch (152 mm) 99.99% Efficiency on 0.3 microns
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Single Piece Stainless Steel Side and Back Wall Construction
Motor(s) 3/4 HP DC ECM
Plenum Type HEPEX
Pre-filter N/A
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.99% Efficiency on 0.3 microns
Viewing Window Inches (mm) 21 (533) open to fully closed
Work Access Opening(s) 8, 10-inch (203, 254 mm)
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 43 (1092)
Est. Shipping Height Inches (mm) 75 (1905)
Est. Shipping Width Inches (mm) 84 (2137)
Exterior Depth Inches (mm) 32 1/8 (817)
Exterior Depth with Armrest Removed Inches (mm) 31 7/16 (799)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 87.375 (2219)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 93.375 (2371)
Exterior Width Inches (mm) 77 5/8 (1972)
Nominal Width Feet (Meters) 6 ft. (1.8m)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 69 7/8 (1775)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 25 3/4 (654)
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) Inquire
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 70 3/8 (1788)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 4.8
Blower/Lights Amps [12-inch (305 mm) Access Opening]
Blower/Lights Amps [14-inch (356mm) Access Opening]
Blower/Lights Amps [8-inch (203 mm) Access Opening] 4.5
Electrical Configuration 115V60Hz
Junction Box Optional
Outlet Amps 3
Power Cord Single 12-foot (3.7 m) 12 GA-3 Wire, 20A Std., 15A Optional
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 14
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 ≤ 60 dba
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 634 (1077)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 538-763 (915-1297)
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 532 (904)
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 436-661 (741-1124)
Bag In Bag Out N/A
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 1884
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) 1768
Heat Rejected Vented (BTU/Hour) 198
Other Built-in Exhaust Option(s) N/A
Plant Duct Static Pressure Inches (mm) 0.05-0.1"/1.27-2.54mm H2O
Australian Test Method N/A
Performance Standard NSF-ANSI-49
Safety Certification
Air Cleanliness (ISO 14644) ISO-Class-5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor Pressure
Control System AeroMax
Est. Shipping Weight lbs (kg) 670 lbs. / 304 kg.
Net Weight lbs (kg) 620 lbs. / 281 kg.
Blower Contact Wires Optional
Closure Panels Optional Rear Closure Panels for Seismic Brackets
Cord Pass Through Standard Right, Optional Left
Double Exhaust HEPA Filter N/A
Gas Supply Interlock with Blower N/A
Glass Sidewalls N/A
IV Bar with 6 Hooks Optional
Magnifying Glass in Window N/A
Motorized Base Stand Optional as Separate Accessory
Motorized Window N/A
Other Built-in Supply Filter Option(s) N/A
Outlet(s) Standard, two backwall
Plumbing Optional 3/8" Soft Copper, 3/8" Black Pipe (Gas Only), or 1/2" Rigid Copper
Remote Service Valves N/A
Seismic Brackets or Studs Optional Rear or Floor Mount Seismic Brackets
Service Couplings (3/8-inch NPT) Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Three Each Side Wall Optional
Service Valves (3/8-inch NPT) One Valve on Right Side Wall is Standard, Maximum of Three Each Side Wall Optional
Side Panels Optional with Plumbing out Bottom, Top or Back
Smooth Interior N/A
Ultraviolet (UV) Light Optional
Window Edge Protector Optional
Access Opening Glass Type Safety Plate
Armrest Standard Plastic with Optional Stainless Steel
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Casters N/A
Decontamination Seal-able Window N/A
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 6-inch (152 mm) 99.99% Efficiency on 0.3 microns
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Single Piece Stainless Steel Side and Back Wall Construction
Motor(s) 3/4 HP DC ECM
Plenum Type HEPEX
Pre-filter N/A
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.99% Efficiency on 0.3 microns
Viewing Window Inches (mm) 21 (533) open to fully closed
Work Access Opening(s) 10-inch (254 mm)
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 43 (1092)
Est. Shipping Height Inches (mm) 75 (1905)
Est. Shipping Width Inches (mm) 84 (2137)
Exterior Depth Inches (mm) 32 1/8 (817)
Exterior Depth with Armrest Removed Inches (mm) 31 7/16 (799)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 88 3/8 (2245)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 94 3/8 (2397)
Exterior Width Inches (mm) 77 5/8 (1972)
Nominal Width Feet (Meters) 6 ft. (1.8m)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 69 7/8 (1775)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 25 3/4 (654)
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) N/A
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 70 3/8 (1788)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 4.8
Blower/Lights Amps [12-inch (305 mm) Access Opening]
Blower/Lights Amps [14-inch (356mm) Access Opening]
Blower/Lights Amps [8-inch (203 mm) Access Opening]
Electrical Configuration 230V5060Hz
Junction Box Optional
Outlet Amps 3
Power Cord Single 12-foot (3.7 m) 14 GA-3 Wire, 15A Std.
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 11
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 ≤ 60 dba
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 634 (1077)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 538-763 (915-1297)
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
Bag In Bag Out N/A
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 1884
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) N/A
Heat Rejected Vented (BTU/Hour) 198
Other Built-in Exhaust Option(s) N/A
Plant Duct Static Pressure Inches (mm) 0.05-0.1"/1.27-2.54mm H2O
Australian Test Method N/A
Performance Standard NSF-ANSI-49
Safety Certification
Air Cleanliness (ISO 14644) ISO-Class-5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor Pressure
Control System AeroMax
Est. Shipping Weight lbs (kg) 670 lbs. / 304 kg.
Net Weight lbs (kg) 620 lbs. / 281 kg.

Review

Resources

Options

  • 3-foot (0.9 meter)
  • 4-foot (1.2 meter)
  • 5-foot (1.5 meter)
  • 6-foot (1.8 meter)
  • Stainless Steel Coved Interior, Cord Pass Through Right Sidewall, 2 Left Couplings, 1 Right Coupling and 1 Right Valve
  • 10-inch (254 mm) Access Opening, Manual Adjustable, Tempered Glass
  • 8-inch (203 mm) Access Opening, Manual Adjustable, Tempered Glass
  • 115V, 60Hz
  • 230V, 50/60 Hz
  • Qty 2 Duplex, NEMA 5-15R, 3 Amp Max, 115V
  • GFI, Qty 2 Duplex NEMA 5-15R, 3 Amp Max, 115V
  • GFI, Qty 2 Duplex NEMA 5-15R, 15 Amp Max, Dedicated NEMA 5-15P Power Cord, 115V
  • GFI, Qty 2 Duplex NEMA 5-20R, 20 Amp Max, Dedicated NEMA 5-20P Power Cord, 115V
  • GFI, Qty 2 Duplex NEMA 5-15R, 5 Amp Max, Removes Accessory Outlet, 115V
  • Qty 2, Socket Type B, 3 Amp Max, 230V
  • Qty 2, Socket Type D, 3 Amp Max, 230V
  • Qty 2, Socket Type E, 3 Amp Max, 230V
  • Qty 2, Socket Type F, 3 Amp Max, 230V
  • Qty 2, Socket Type G, 3 Amp Max, 230V
  • Qty 2, Socket Type H, 3 Amp Max, 230V
  • Qty 2, Socket Type I, 3 Amp Max, 230V
  • Qty 2, Socket Type J, 3 Amp Max, 230V
  • Qty 2, Socket Type K, 3 Amp Max, 230V
  • Qty 2, Socket Type M, 3 Amp Max, 230V
  • No UV Light, Field Retrofittable
  • UV Light Backwall
  • 3-inch (76 mm) Supply, 6-inch (152 mm) Exhaust Metal Frame Separatorless 99.99% @ 0.3 Micron HEPA Filters with Permanent Plenum
  • Left Top Service Valve
  • Left Middle Service Valve
  • Left Bottom Service Valve
  • Right Top Service Valve
  • Right Middle Service Valve
  • Left Top Service Coupling
  • Right Top Service Coupling
  • Right Bottom Service Coupling, Replaces Right Bottom Service Valve
  • Rigid Copper 1/2-inch
  • Black Pipe 3/8-inch
  • Soft Copper 3/8-inch
  • Stainless Steel Flexible Pipe 96-inches (2439 mm)
  • CSST Yellow Flexible Pipe 96-inches (2439 mm)
  • Side Panels without Plumbing
  • Side Panels with Plumbing Out Bottom
  • Side Panels with Plumbing Out Top
  • Side Panels with Plumbing Out Back
  • Cord Pass-Thru Left Sidewall, NSF Approved
  • Stainless Steel Armrest
  • IV Bar with 6 hooks and 3 height locations
  • Stainless Steel Window Edge Protector
  • Blower Contact Wires
  • Power Cord with Twist Lock Plug
  • Cable Management Brackets
  • Telescoping Base Stand, Leg Levelers
  • Telescoping Base Stand, Casters
  • Motorized Base Stand, Leg Levelers
  • Motorized Base Stand, Casters
  • Telescoping Base Stand with Storage Cabinet, Leg Levelers
  • Telescoping Base Stand with Storage Cabinet, Casters
  • Telescoping Base Stand, Seismic/OPM, Leg Levelers Shipped Factory Assembled
  • Motorized Base Stand, Seismic Floor Mount, Leg Levelers
  • Telescoping Base Stand, Fully Welded, Leg Levelers Shipped Factory Assembled
  • Base Stand Shelf 8-inches (203mm)
  • Base Stand Shelf 12-inches (305mm)
  • Ergotron Workstation for Telescoping Base Stand
  • Ergotron Workstation for Motorized Base Stand
  • Ergotron Laptop Arm for Telescoping Biosafety Cabinet Base Stands
  • Ergotron Laptop Arm for Automatic Adjustable Biosafety Cabinet Base Stands
  • Rear Closure Panel
  • Seismic Brackets, Rear Mount for Telescoping Base Stand
  • Seismic Brackets, Rear Mount for Motorized Base Stand
  • Seismic Brackets, Floor Mount for Telescoping Base Stand
  • Variable Range Low Flow Exhaust Canopy with Monitor
  • Fixed Range Transition
  • 25% Fill Activated Charcoal Filter Exhaust Transition
  • 25% Fill Purafill Filter Exhaust Transition
  • Flex Duct, 8-feet (2.4 m), Qty 2 Stainless Steel Band Clamps
  • Manual Air Tight Stainless Steel Butterfly Damper
  • 8-inch (203 mm) to 10-inch (254 mm) Round to Round Transition
  • Adjustable Footrest
  • Forearm Pad for Armrest (Disposable Pkg of 10)
  • Stainless Steel Table, Rotating, 12-inch (305 mm) Diameter
  • Silicone Pad Elbow Rest 3 x 5-inches (76 x 127 mm)
  • Silicone Pad Elbow Rest 3 x 10-inches (76 x 254 mm)
  • Ergonomic Accessory Kit

Request Your Quote for a NU-540

Please fill out the form below for a lab equipment quote and we'll get to work on getting you what you need. Need to talk with someone right away? Give us a call at 763-553-1270.

Thank you for completing the form.

We will be in touch. If you have any urgent questions, please reach out at 763-553-1270.