In-VitroCell NU-5700 Direct Heat CO2 Incubator

The NU-5700 CO2 Incubator offers advanced temperature and CO2 control, HEPA-filtered air circulation, and a user-friendly touch screen for optimal cell culture conditions.

Overview

The NU-5700 CO2 Incubator is a state-of-the-art solution for various cell culture applications. It features an intuitive touch panel for controlling and monitoring temperature and CO2 levels. The incubator’s innovative design incorporates an infrared sensor ensuring precise CO2 control and separately adjustable door and perimeter heaters for balanced internal temperature. Its 160L growth chamber is complemented by an external air pump that circulates HEPA-filtered air, maintaining clean air at positive pressure to minimize contamination risks. The user-friendly touch screen facilitates easy setting adjustments and historical data access. With the capability to be stacked, the NU-5700 offers convenient access to the top chamber, making it a versatile and efficient choice for any cell culture laboratory seeking a controlled and balanced growth environment.

NuTouch Touchscreen Controls

Enhance your lab's efficiency with the intuitive NuTouch control system, a standard feature on all NuAire CO2 incubators. This user-friendly interface simplifies your daily tasks, allowing effortless adjustments of set points, easy access to chamber history, and quick initiation of decontamination cycles or calibration procedures. Designed for the modern laboratory, the NuTouch system offers a consistent user experience across all NuAire incubators, enabling seamless transition and operation between different units in your lab. Experience the convenience and reliability of NuTouch, streamlining your research processes with precision and ease.

Uniform Heat Distribution

Experience unparalleled temperature consistency with our direct heat incubator, designed for precision and reliability. Its innovative heating elements, strategically positioned around the chamber, around the door perimeter, and within the door itself, ensure a balanced temperature distribution within a robust, insulated chamber. With the capability to independently adjust door and perimeter heaters, our incubator guarantees uniform temperature control, adapting effortlessly to varying ambient conditions. This feature ensures optimal performance and stability for sensitive incubation processes, regardless of external temperature fluctuations, making it an essential tool for demanding laboratory environments.

HEPA Filtration and Contamination Control

Experience the Assurance of Constant Contamination Control: Our advanced design features continual HEPA filtration, creating consistent, clean air conditions similar to an ISO Class 5 cleanroom within the chamber. By routing air through an external HEPA filter and returning it to the chamber, we ensure a high level of cleanliness and slight positive pressure for added protection. This creates a multi-tiered defense system to safeguard your cell cultures against contamination, ensuring their integrity and your peace of mind.

Precise CO2 Control, Minimal Calibrations

Experience precision and stability with InVitrocell's Advanced Dual Wave IR Sensor: This sensor is designed to control CO2 levels accurately and ensures optimal pH in your growth chamber. Its unique dual-wave infrared technology targets only CO2, eliminating interference from water vapor and other elements. This results in a remarkably stable output with minimal drift, reducing the need for frequent recalibrations and ensuring consistent, reliable conditions for your cell cultures.

Specifications

NU-5700 CO2 Incubator
CO2 Accuracy ± 0.1%
CO2 Control Logic Fixed Algorithm/Manual, Environmental Adaptable
CO2 Display Resolution 0.1%
CO2 Range 0.1 to 20%, 5% Default Set Point
CO2 Recovery Up to 5% ± 0.2% / -0.5 in 5 minutes Average
CO2 Sensor Type Infrared (NDIR)
Segmented Doors Optional Set of 4 Inner Doors
Access Port Location Right Side
Chamber Air Filter 99.97% Efficiency @ ≥ 0.3 Micron Capsule Filter Located in Sensor Bay
Exterior Door Seal Magnetic Outer Door Gasket
Exterior Material Cold Rolled 16 & 18 Gauge Steel, Finished in Powder Coated Polyurethane Finish
In-line Gas Filters 99.97% Efficiency @ ≥ 0.3 Micron Disk Filters for Gas & Air Supplies, Disk Filter for CO2 Sensor
Inner Doors One, Sectioned Optional
Insulation High Density Insulation with High R Rating
Interior Door Seal Silicone Rubber Gasket
Interior Material Highly Polished Type 304L 16 Gauge Stainless Steel
Sample Port Location Inner Glass Door
Shelf Capacity lbs (kg) 25 lbs per Shelf / 125 lbs per Incubator
Shelf Material Stainless Steel
Shelves 4 Shelves Supplied, 16 Shelves Maximum Capacity
Data Output Features RS-485, USB, 4-20mA
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 31 (787)
Est. Shipping Height Inches (mm) 47 (1194)
Est. Shipping Width Inches (mm) 30 (762)
Exterior Depth Inches (mm) 27.500 (699)
Exterior Height Inches (mm) 36.188 (894)
Exterior Width Inches (mm) 25.500 (648)
Footprint Depth inches (mm) 20.825 (530)
Footprint Width inches (mm) 22.625 (575)
Interior Depth Inches (mm) 20.678 (525)
Interior Height Inches (mm) 24.000 (610)
Interior Volume Cubic Feet (Liters) 5.65 (160)
Interior Width Inches (mm) 20.250 (514)
Shelf Depth Inches (mm) 18 3/4 (476)
Shelf Width Inches (mm) 18 (457)
Water Pan Depth 1.5 (38)
Water Pan Length Inches (mm) 12 (305)
Water Pan Width 10 (254)
Electrical Configuration 115V 60Hz
Power Cord Length Foot (Meter) 8 (2.5)
Safety Certification UL, UL-C, UK CA
Chamber Air Circulation Method Air Pump
Chamber Jacket Technology Air Jacket via Two Axial Fans Drawing Air into Shell
Control System NuTouch
Chamber Heater(s) Location Sides, Bottom, Top and Back of Chamber
Door and Perimeter Heater Control Logic Base Duty Cycle set to chamber temperature Set-Point, Proportional 0-100% [manually adjustable]
Temperature Accuracy °C ± 0.1%
Temperature Control Direct Heat
Temperature Control Range 5°C above ambient (to a 30°C max ambient) to 55°C
Temperature Display Resolution 0.1°C
Temperature Recovery 0.12°C/min. on Average
Temperature Sensor Type Precision Integrated Circuit
Temperature Set-Point Range 5°C to 55°C (37.0°C Default)
Temperature Uniformity °C ± 0.35°C @ 37°C
Est. Shipping Weight lbs (kg) Estimated 275 lbs (125 kgs)
Net Weight lbs (kg) 220 (100)
CO2 Accuracy ± 0.1%
CO2 Control Logic Fixed Algorithm/Manual, Environmental Adaptable
CO2 Display Resolution 0.1%
CO2 Range 0.1 to 20%, 5% Default Set Point
CO2 Recovery Up to 5% ± 0.2% / -0.5 in 5 minutes Average
CO2 Sensor Type Infrared (NDIR)
Segmented Doors Optional Set of 4 Inner Doors
Access Port Location Right Side
Chamber Air Filter 99.97% Efficiency @ ≥ 0.3 Micron Capsule Filter Located in Sensor Bay
Exterior Door Seal Magnetic Outer Door Gasket
Exterior Material Cold Rolled 16 & 18 Gauge Steel, Finished in Powder Coated Polyurethane Finish
In-line Gas Filters 99.97% Efficiency @ ≥ 0.3 Micron Disk Filters for Gas & Air Supplies, Disk Filter for CO2 Sensor
Inner Doors One, Sectioned Optional
Insulation High Density Insulation with High R Rating
Interior Door Seal Silicone Rubber Gasket
Interior Material Highly Polished Type 304L 16 Gauge Stainless Steel
Sample Port Location Inner Glass Door
Shelf Capacity lbs (kg) 25 lbs per Shelf / 125 lbs per Incubator
Shelf Material Stainless Steel
Shelves 4 Shelves Supplied, 16 Shelves Maximum Capacity
Data Output Features RS-485, USB, 4-20mA
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 31 (787)
Est. Shipping Height Inches (mm) 47 (1194)
Est. Shipping Width Inches (mm) 30 (762)
Exterior Depth Inches (mm) 27.500 (699)
Exterior Height Inches (mm) 36.188 (894)
Exterior Width Inches (mm) 25.500 (648)
Footprint Depth inches (mm) 20.825 (530)
Footprint Width inches (mm) 22.625 (575)
Interior Depth Inches (mm) 20.678 (525)
Interior Height Inches (mm) 24.000 (610)
Interior Volume Cubic Feet (Liters) 5.65 (160)
Interior Width Inches (mm) 20.250 (514)
Shelf Depth Inches (mm) 18 3/4 (476)
Shelf Width Inches (mm) 18 (457)
Water Pan Depth 1.5 (38)
Water Pan Length Inches (mm) 12 (305)
Water Pan Width 10 (254)
Electrical Configuration 230V 50/60Hz
Power Cord Length Foot (Meter) 8 (2.5)
Safety Certification UL, UL-C, UK CA
Chamber Air Circulation Method Air Pump
Chamber Jacket Technology Air Jacket via Two Axial Fans Drawing Air into Shell
Control System NuTouch
Chamber Heater(s) Location Sides, Bottom, Top and Back of Chamber
Door and Perimeter Heater Control Logic Base Duty Cycle set to chamber temperature Set-Point, Proportional 0-100% [manually adjustable]
Temperature Accuracy °C ± 0.1%
Temperature Control Direct Heat
Temperature Control Range 5°C above ambient (to a 30°C max ambient) to 55°C
Temperature Display Resolution 0.1°C
Temperature Recovery 0.12°C/min. on Average
Temperature Sensor Type Precision Integrated Circuit
Temperature Set-Point Range 5°C to 55°C (37.0°C Default)
Temperature Uniformity °C ± 0.35°C @ 37°C
Est. Shipping Weight lbs (kg) Estimated 275 lbs (125 kgs)
Net Weight lbs (kg) 220 (100)

Review

Options

  • 115V, 60Hz, 15 Amp, NEMA 5-15P, Made in USA
  • 230V, 50/60 Hz, 15 Amp, Type F Plug, Made in USA
  • 230V, 50/60 Hz, 15 Amp, Plug Type G, Made in USA
  • Stainless Steel Chamber with Floor Mounted Water Pan
  • Stainless Steel Shelves (Qty 4)
  • Heavy Duty Stainless Steel Shelves (Qty 4)
  • Copper Alloy Shelves (Qty 4)
  • CO2 Incubator Shelf, Stainless Steel (Qty 1) with Guide Brackets (Qty 2)
  • CO2 Incubator Copper Alloy Shelf (Qty 1) with Guide Brackets (Qty 2)
  • CO2 Incubator Shelf, Stainless Steel, Heavy Duty (Qty 1) with Guide Brackets (Qty 2)
  • Left Hinged Door Swing
  • Right Hinged Door Swing
  • Standard Glass Door with Cam Action Lock
  • Sectioned Inner Door with Cam Action Locks (4 Vertical Sections)
  • Regulator CO2 - Two Stage
  • Tank Switch, External, CO2
  • Tubing Kit (1)

Request Your Quote for a NU-5700

Please fill out the form below for a lab equipment quote and we'll get to work on getting you what you need. Need to talk with someone right away? Give us a call at 763-553-1270.

Thank you for completing the form.

We will be in touch. If you have any urgent questions, please reach out at 763-553-1270.