In-VitroCell NU-5810 Direct Heat CO2 Incubator

The In-VitroCell ES (Energy Saver) NU-5810 Microbiological CO2 Incubator features a 145°C dry decontamination cycle and 95°C humidified decontamination cycle as an added defensive against incubator contamination providing an optimally controlled environment for cell growth.
Available for

Overview

The In-VitroCell NU-5810 Direct Heat CO2 Incubator is expertly crafted to foster optimal cell growth conditions. Equipped with dual decontamination cycles, it ensures precise control over temperature and CO2 levels, bolstered by cutting-edge microprocessor technology. This design meets the highest performance standards and excels in minimizing contamination risks. Its advanced capabilities make it ideal for meticulously storing and preserving gametes and tissue cell cultures at or near body temperature. It provides a reliable and controlled environment essential for modern laboratory demands.

Efficient Overnight Decontamination

Optimize Cell Culture Conditions with Dual Decontamination Cycles: Our direct heat technology facilitates two thorough decontamination modes – a 145°C dry and 95°C humidified cycle. Efficiently executed overnight in just 8 hours, these cycles aid in maintaining a pristine chamber environment, acting as both preventative maintenance and a means to address contamination. The intuitive NuTouch control system guides you through the process with clear on-screen instructions, tracking each phase's progress for a hassle-free, comprehensive clean.

Optimize Cell Culture Growth with HEPA Filtration

The In-VitroCell system constantly circulates chamber air through external HEPA filters, creating a contaminant-free environment. This closed-loop filtration maintains a clean air setting ideal for sensitive cell cultures, effectively minimizing the risk of contamination and cell desiccation. Experience a new standard of cell culture protection with In-VitroCell's advanced HEPA filtration, ensuring the integrity and optimal growth of your cell cultures.

Seamless Cleaning with Coved Corners

NuAire CO2 Incubators feature coved interior corners, eliminating hard-to-reach areas where contaminants can hide. This design minimizes the risk of contamination and simplifies the cleaning process. The smooth, crevice-free interior ensures thorough disinfection, providing an optimal, clean environment for cell culture growth.

Streamlined Touch Control for Optimal Culture Growth

NuAire's NuTouch control system delivers an intuitive, user-friendly experience, making it easier for lab technicians to navigate various parameters for optimal culture growth. Its simple interface allows users to adjust set points, review chamber history, initiate decontamination cycles, and perform calibration procedures. This modern touchscreen control streamlines incubator operation, ensuring lab personnel can maintain ideal growth conditions with ease and efficiency.

Specifications

In-VitroCell NU-5810 Direct Heat 200-Liter CO2 Incubator featuring Dual Decontamination Cycles
CO2 Accuracy ± 0.1%
CO2 Control Logic Fixed Algorithm/Manual, Environmental Adaptable
CO2 Display Resolution 0.1%
CO2 Range 0.1 to 20%, 5% Default Set Point
CO2 Recovery Up to 5% ± 0.2% / -0.5 in 5 minutes Average
CO2 Sensor Type Infrared (NDIR)
Segmented Doors Optional Set of 4 Inner Doors
Access Port Location Right Side
Chamber Air Filter 99.97% Efficiency @ ≥ 0.3 Micron Capsule Filter Located in Sensor Bay
Exterior Door Seal Magnetic Outer Door Gasket
Exterior Material Cold Rolled 16 & 18 Gauge Steel, Finished in Powder Coated Polyurethane Finish
In-line Gas Filters 99.97% Efficiency @ ≥ 0.3 Micron Disk Filters for Gas & Air Supplies, Disk Filter for CO2 Sensor
Inner Doors One, single or sectional
Insulation High Density Insulation with High "R" Rating
Interior Door Seal Silicone Rubber Gasket
Interior Material Highly Polished Type 304L 16 Gauge Stainless Steel
Sample Port Location Inner Glass Door
Shelf Capacity lbs (kg)
Shelf Material Stainless Steel or Stainless Steel Enriched Copper
Shelves 4 Shelves Supplied, 20 Shelves Maximum Capacity
Data Output Features RS-485, USB, 4-20mA
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 31 (787)
Est. Shipping Height Inches (mm) 51(1219)
Est. Shipping Width Inches (mm) 31 (787)
Exterior Depth Inches (mm) 27.188 (691)
Exterior Height Inches (mm) 39.688 (1008)
Exterior Width Inches (mm) 26.750 (680)
Footprint Depth inches (mm) 20.75 (527)
Footprint Width inches (mm) 23.75 (603)
Interior Depth Inches (mm) 20.053 (509)
Interior Height Inches (mm) 28.500 (724)
Interior Volume Cubic Feet (Liters) 7.06 (200)
Interior Width Inches (mm) 21.257 (540)
Shelf Depth Inches (mm) 18 3/4 (476)
Shelf Width Inches (mm) 19 3/4 (502)
Water Pan Depth 1.5 (38)
Water Pan Length Inches (mm) 12 (305)
Water Pan Width 10 (254)
Electrical Configuration 115V60Hz
Power Cord Length Foot (Meter) 8 (2.5)
Safety Certification UL, UL-C
O2 Accuracy
O2 Control Logic
O2 Display Resolution
O2 Measuring Range
O2 Recovery
O2 Sensor Type
O2 Set Point Range
Decontamination Cycle 95°C Humidified Decontamination, 145°C Dry Decontamination Cycle
RH Accuracy
RH Control Logic
RH Control Method Water Pan, Convection
RH Control Range
RH Display Resolution
RH Evaporator Box Capacity
RH Recovery
RH Sensor Type
RH Water Pan Capacity
Chamber Air Circulation Method Air Pump
Chamber Jacket Technology Air Jacket via Two Axial Fans Drawing Air into Shell
Control System NuTouch
Chamber Heater(s) Location Sides, Bottom, Top and Back of Chamber
Door and Perimeter Heater Control Logic Base Duty Cycle set to chamber temperature Set-Point, Proportional 0-100% [manually adjustable]
Temperature Accuracy °C ± 0.1%
Temperature Control Direct Heat
Temperature Control Range 5°C above ambient (to a 30°C max ambient) to 55°C
Temperature Display Resolution 0.1°C
Temperature Recovery 0.12°C/min. on Average
Temperature Sensor Type Precision Integrated Circuit
Temperature Set-Point Range 5°C to 55°C (37.0°C Default)
Temperature Uniformity °C ± 0.35°C @ 37°C
Est. Shipping Weight lbs (kg) 325 (147)
Net Weight lbs (kg) 235 (106)
CO2 Accuracy ± 0.1%
CO2 Control Logic Fixed Algorithm/Manual, Environmental Adaptable
CO2 Display Resolution 0.1%
CO2 Range 0.1 to 20%, 5% Default Set Point
CO2 Recovery Up to 5% ± 0.2% / -0.5 in 5 minutes Average
CO2 Sensor Type Infrared (NDIR)
Segmented Doors Optional Set of 4 Inner Doors
Access Port Location Right Side
Chamber Air Filter 99.97% Efficiency @ ≥ 0.3 Micron Capsule Filter Located in Sensor Bay
Exterior Door Seal Magnetic Outer Door Gasket
Exterior Material Cold Rolled 16 & 18 Gauge Steel, Finished in Powder Coated Polyurethane Finish
In-line Gas Filters 99.97% Efficiency @ ≥ 0.3 Micron Disk Filters for Gas & Air Supplies, Disk Filter for CO2 Sensor
Inner Doors One, single or sectional
Insulation High Density Insulation with High "R" Rating
Interior Door Seal Silicone Rubber Gasket
Interior Material Highly Polished Type 304L 16 Gauge Stainless Steel
Sample Port Location Inner Glass Door
Shelf Capacity lbs (kg)
Shelf Material Stainless Steel or Stainless Steel Enriched Copper
Shelves 4 Shelves Supplied, 20 Shelves Maximum Capacity
Data Output Features RS-485, USB, 4-20mA
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 31 (787)
Est. Shipping Height Inches (mm) 51(1219)
Est. Shipping Width Inches (mm) 31 (787)
Exterior Depth Inches (mm) 27.188 (691)
Exterior Height Inches (mm) 39.688 (1008)
Exterior Width Inches (mm) 26.750 (680)
Footprint Depth inches (mm) 20.75 (527)
Footprint Width inches (mm) 23.75 (603)
Interior Depth Inches (mm) 20.053 (509)
Interior Height Inches (mm) 28.500 (724)
Interior Volume Cubic Feet (Liters) 7.06 (200)
Interior Width Inches (mm) 21.257 (540)
Shelf Depth Inches (mm) 18 3/4 (476)
Shelf Width Inches (mm) 19 3/4 (502)
Water Pan Depth 1.5 (38)
Water Pan Length Inches (mm) 12 (305)
Water Pan Width 10 (254)
Electrical Configuration 230V5060Hz
Power Cord Length Foot (Meter) 8 (2.5)
Safety Certification UL, UL-C
O2 Accuracy
O2 Control Logic
O2 Display Resolution
O2 Measuring Range
O2 Recovery
O2 Sensor Type
O2 Set Point Range
Decontamination Cycle 95°C Humidified Decontamination, 145°C Dry Decontamination Cycle
RH Accuracy
RH Control Logic
RH Control Method Water Pan, Convection
RH Control Range
RH Display Resolution
RH Evaporator Box Capacity
RH Recovery
RH Sensor Type
RH Water Pan Capacity
Chamber Air Circulation Method Air Pump
Chamber Jacket Technology Air Jacket via Two Axial Fans Drawing Air into Shell
Control System NuTouch
Chamber Heater(s) Location Sides, Bottom, Top and Back of Chamber
Door and Perimeter Heater Control Logic Base Duty Cycle set to chamber temperature Set-Point, Proportional 0-100% [manually adjustable]
Temperature Accuracy °C ± 0.1%
Temperature Control Direct Heat
Temperature Control Range 5°C above ambient (to a 30°C max ambient) to 55°C
Temperature Display Resolution 0.1°C
Temperature Recovery 0.12°C/min. on Average
Temperature Sensor Type Precision Integrated Circuit
Temperature Set-Point Range 5°C to 55°C (37.0°C Default)
Temperature Uniformity °C ± 0.35°C @ 37°C
Est. Shipping Weight lbs (kg) 325 (147)
Net Weight lbs (kg) 235 (106)

Review

Options

  • 115V, 60Hz, 15 Amp, NEMA 5-15P, Made in USA
  • 230V, 50/60 Hz, 15 Amp, Type F Plug, Made in USA
  • 230V, 50/60 Hz, 15 Amp, Plug Type G, Made in USA
  • Stainless Steel Chamber with Floor Mounted Water Pan
  • Stainless Steel Shelves (Qty 4)
  • Heavy Duty Stainless Steel Shelves (Qty 4)
  • Copper Alloy Shelves (Qty 4)
  • Left Hinged Door Swing
  • Right Hinged Door Swing
  • Standard Glass Door with Cam Action Lock
  • Sectioned Inner Door with Cam Action Locks, 6 Sections (2x3)
  • Platform with Combination Leg Levelers and Casters
  • Stacking Brackets
  • Stacking Rack, Floor Mount
  • Regulator CO2 - Two Stage
  • Tank Switch, External, CO2 or N2
  • Tubing Kit (1)
  • Water Pan, Copper Alloy, Qty 1
  • Water Pan, Stainless Steel, Qty 1
  • CO2 Incubator Shelf, Copper Alloy, Qty1
  • CO2 Incubator Shelf, Stainless Steel, Qty1
  • CO2 Incubator Shelf, Stainless Steel, Heavy Duty, Qty1
  • Fyrite Kit CO2 Analyzer (Dry)
  • Replacement Fluid CO2 Analyzer (carton)
  • Duplex Outlet Moisture Proof, 115V
  • Surge Protector, 115V

Request Your Quote for a NU-5810

Please fill out the form below for a lab equipment quote and we'll get to work on getting you what you need. Need to talk with someone right away? Give us a call at 763-553-1270.

Thank you for completing the form.

We will be in touch. If you have any urgent questions, please reach out at 763-553-1270.