In-VitroCell NU-5810 Direct Heat CO2 Incubator
The In-VitroCell ES (Energy Saver) NU-5810 Microbiological CO2 Incubator features a 145°C dry decontamination cycle and 95°C humidified decontamination cycle as an added defensive against incubator contamination providing an optimally controlled environment for cell growth.
Available for
- Overview
- Specifications
- Reviews
- Resources
- Options
Overview
The In-VitroCell NU-5810 Direct Heat CO2 Incubator is expertly crafted to foster optimal cell growth conditions. Equipped with dual decontamination cycles, it ensures precise control over temperature and CO2 levels, bolstered by cutting-edge microprocessor technology. This design meets the highest performance standards and excels in minimizing contamination risks. Its advanced capabilities make it ideal for meticulously storing and preserving gametes and tissue cell cultures at or near body temperature. It provides a reliable and controlled environment essential for modern laboratory demands.
Efficient Overnight Decontamination
Optimize Cell Culture Conditions with Dual Decontamination Cycles: Our direct heat technology facilitates two thorough decontamination modes – a 145°C dry and 95°C humidified cycle. Efficiently executed overnight in just 8 hours, these cycles aid in maintaining a pristine chamber environment, acting as both preventative maintenance and a means to address contamination. The intuitive NuTouch control system guides you through the process with clear on-screen instructions, tracking each phase's progress for a hassle-free, comprehensive clean.
Optimize Cell Culture Growth with HEPA Filtration
The In-VitroCell system constantly circulates chamber air through external HEPA filters, creating a contaminant-free environment. This closed-loop filtration maintains a clean air setting ideal for sensitive cell cultures, effectively minimizing the risk of contamination and cell desiccation. Experience a new standard of cell culture protection with In-VitroCell's advanced HEPA filtration, ensuring the integrity and optimal growth of your cell cultures.
Seamless Cleaning with Coved Corners
NuAire CO2 Incubators feature coved interior corners, eliminating hard-to-reach areas where contaminants can hide. This design minimizes the risk of contamination and simplifies the cleaning process. The smooth, crevice-free interior ensures thorough disinfection, providing an optimal, clean environment for cell culture growth.
Streamlined Touch Control for Optimal Culture Growth
NuAire's NuTouch control system delivers an intuitive, user-friendly experience, making it easier for lab technicians to navigate various parameters for optimal culture growth. Its simple interface allows users to adjust set points, review chamber history, initiate decontamination cycles, and perform calibration procedures. This modern touchscreen control streamlines incubator operation, ensuring lab personnel can maintain ideal growth conditions with ease and efficiency.
Specifications
CO2 Accuracy | ± 0.1% |
CO2 Control Logic | Fixed Algorithm/Manual, Environmental Adaptable |
CO2 Display Resolution | 0.1% |
CO2 Range | 0.1 to 20%, 5% Default Set Point |
CO2 Recovery | Up to 5% ± 0.2% / -0.5 in 5 minutes Average |
CO2 Sensor Type | Infrared (NDIR) |
Segmented Doors | Optional Set of 4 Inner Doors |
Access Port Location | Right Side |
Chamber Air Filter | 99.97% Efficiency @ ≥ 0.3 Micron Capsule Filter Located in Sensor Bay |
Exterior Door Seal | Magnetic Outer Door Gasket |
Exterior Material | Cold Rolled 16 & 18 Gauge Steel, Finished in Powder Coated Polyurethane Finish |
In-line Gas Filters | 99.97% Efficiency @ ≥ 0.3 Micron Disk Filters for Gas & Air Supplies, Disk Filter for CO2 Sensor |
Inner Doors | One, single or sectional |
Insulation | High Density Insulation with High "R" Rating |
Interior Door Seal | Silicone Rubber Gasket |
Interior Material | Highly Polished Type 304L 16 Gauge Stainless Steel |
Sample Port Location | Inner Glass Door |
Shelf Capacity lbs (kg) | |
Shelf Material | Stainless Steel or Stainless Steel Enriched Copper |
Shelves | 4 Shelves Supplied, 20 Shelves Maximum Capacity |
Data Output Features | RS-485, USB, 4-20mA |
Remote Alarm Terminals | Standard |
Est. Shipping Depth Inches (mm) | 31 (787) |
Est. Shipping Height Inches (mm) | 51(1219) |
Est. Shipping Width Inches (mm) | 31 (787) |
Exterior Depth Inches (mm) | 27.188 (691) |
Exterior Height Inches (mm) | 39.688 (1008) |
Exterior Width Inches (mm) | 26.750 (680) |
Footprint Depth inches (mm) | 20.75 (527) |
Footprint Width inches (mm) | 23.75 (603) |
Interior Depth Inches (mm) | 20.053 (509) |
Interior Height Inches (mm) | 28.500 (724) |
Interior Volume Cubic Feet (Liters) | 7.06 (200) |
Interior Width Inches (mm) | 21.257 (540) |
Shelf Depth Inches (mm) | 18 3/4 (476) |
Shelf Width Inches (mm) | 19 3/4 (502) |
Water Pan Depth | 1.5 (38) |
Water Pan Length Inches (mm) | 12 (305) |
Water Pan Width | 10 (254) |
Electrical Configuration | 115V60Hz |
Power Cord Length Foot (Meter) | 8 (2.5) |
Safety Certification | UL, UL-C |
O2 Accuracy | |
O2 Control Logic | |
O2 Display Resolution | |
O2 Measuring Range | |
O2 Recovery | |
O2 Sensor Type | |
O2 Set Point Range |
Decontamination Cycle | 95°C Humidified Decontamination, 145°C Dry Decontamination Cycle |
RH Accuracy | |
RH Control Logic | |
RH Control Method | Water Pan, Convection |
RH Control Range | |
RH Display Resolution | |
RH Evaporator Box Capacity | |
RH Recovery | |
RH Sensor Type | |
RH Water Pan Capacity |
Chamber Air Circulation Method | Air Pump |
Chamber Jacket Technology | Air Jacket via Two Axial Fans Drawing Air into Shell |
Control System | NuTouch |
Chamber Heater(s) Location | Sides, Bottom, Top and Back of Chamber |
Door and Perimeter Heater Control Logic | Base Duty Cycle set to chamber temperature Set-Point, Proportional 0-100% [manually adjustable] |
Temperature Accuracy °C | ± 0.1% |
Temperature Control | Direct Heat |
Temperature Control Range | 5°C above ambient (to a 30°C max ambient) to 55°C |
Temperature Display Resolution | 0.1°C |
Temperature Recovery | 0.12°C/min. on Average |
Temperature Sensor Type | Precision Integrated Circuit |
Temperature Set-Point Range | 5°C to 55°C (37.0°C Default) |
Temperature Uniformity °C | ± 0.35°C @ 37°C |
Est. Shipping Weight lbs (kg) | 325 (147) |
Net Weight lbs (kg) | 235 (106) |
CO2 Accuracy | ± 0.1% |
CO2 Control Logic | Fixed Algorithm/Manual, Environmental Adaptable |
CO2 Display Resolution | 0.1% |
CO2 Range | 0.1 to 20%, 5% Default Set Point |
CO2 Recovery | Up to 5% ± 0.2% / -0.5 in 5 minutes Average |
CO2 Sensor Type | Infrared (NDIR) |
Segmented Doors | Optional Set of 4 Inner Doors |
Access Port Location | Right Side |
Chamber Air Filter | 99.97% Efficiency @ ≥ 0.3 Micron Capsule Filter Located in Sensor Bay |
Exterior Door Seal | Magnetic Outer Door Gasket |
Exterior Material | Cold Rolled 16 & 18 Gauge Steel, Finished in Powder Coated Polyurethane Finish |
In-line Gas Filters | 99.97% Efficiency @ ≥ 0.3 Micron Disk Filters for Gas & Air Supplies, Disk Filter for CO2 Sensor |
Inner Doors | One, single or sectional |
Insulation | High Density Insulation with High "R" Rating |
Interior Door Seal | Silicone Rubber Gasket |
Interior Material | Highly Polished Type 304L 16 Gauge Stainless Steel |
Sample Port Location | Inner Glass Door |
Shelf Capacity lbs (kg) | |
Shelf Material | Stainless Steel or Stainless Steel Enriched Copper |
Shelves | 4 Shelves Supplied, 20 Shelves Maximum Capacity |
Data Output Features | RS-485, USB, 4-20mA |
Remote Alarm Terminals | Standard |
Est. Shipping Depth Inches (mm) | 31 (787) |
Est. Shipping Height Inches (mm) | 51(1219) |
Est. Shipping Width Inches (mm) | 31 (787) |
Exterior Depth Inches (mm) | 27.188 (691) |
Exterior Height Inches (mm) | 39.688 (1008) |
Exterior Width Inches (mm) | 26.750 (680) |
Footprint Depth inches (mm) | 20.75 (527) |
Footprint Width inches (mm) | 23.75 (603) |
Interior Depth Inches (mm) | 20.053 (509) |
Interior Height Inches (mm) | 28.500 (724) |
Interior Volume Cubic Feet (Liters) | 7.06 (200) |
Interior Width Inches (mm) | 21.257 (540) |
Shelf Depth Inches (mm) | 18 3/4 (476) |
Shelf Width Inches (mm) | 19 3/4 (502) |
Water Pan Depth | 1.5 (38) |
Water Pan Length Inches (mm) | 12 (305) |
Water Pan Width | 10 (254) |
Electrical Configuration | 230V5060Hz |
Power Cord Length Foot (Meter) | 8 (2.5) |
Safety Certification | UL, UL-C |
O2 Accuracy | |
O2 Control Logic | |
O2 Display Resolution | |
O2 Measuring Range | |
O2 Recovery | |
O2 Sensor Type | |
O2 Set Point Range |
Decontamination Cycle | 95°C Humidified Decontamination, 145°C Dry Decontamination Cycle |
RH Accuracy | |
RH Control Logic | |
RH Control Method | Water Pan, Convection |
RH Control Range | |
RH Display Resolution | |
RH Evaporator Box Capacity | |
RH Recovery | |
RH Sensor Type | |
RH Water Pan Capacity |
Chamber Air Circulation Method | Air Pump |
Chamber Jacket Technology | Air Jacket via Two Axial Fans Drawing Air into Shell |
Control System | NuTouch |
Chamber Heater(s) Location | Sides, Bottom, Top and Back of Chamber |
Door and Perimeter Heater Control Logic | Base Duty Cycle set to chamber temperature Set-Point, Proportional 0-100% [manually adjustable] |
Temperature Accuracy °C | ± 0.1% |
Temperature Control | Direct Heat |
Temperature Control Range | 5°C above ambient (to a 30°C max ambient) to 55°C |
Temperature Display Resolution | 0.1°C |
Temperature Recovery | 0.12°C/min. on Average |
Temperature Sensor Type | Precision Integrated Circuit |
Temperature Set-Point Range | 5°C to 55°C (37.0°C Default) |
Temperature Uniformity °C | ± 0.35°C @ 37°C |
Est. Shipping Weight lbs (kg) | 325 (147) |
Net Weight lbs (kg) | 235 (106) |
Review
Resources
Brochures
Drawings
Videos
Specifications
BIM Revit
Request Your Quote for a NU-5810
Please fill out the form below for a lab equipment quote and we'll get to work on getting you what you need. Need to talk with someone right away? Give us a call at 763-553-1270.
Thank you for completing the form.
We will be in touch. If you have any urgent questions, please reach out at 763-553-1270.