In-VitroCell NU-5710 Direct HeatCO2 Incubator
- Overview
- Specifications
- Resources
Overview
The In-VitroCell NU-5710 Direct Heat CO2 Incubator is a cutting-edge solution for researchers demanding the highest standards in cell culture. This incubator provides a stable, contamination-free environment crucial for successful cell growth and research outcomes. With precise control of temperature, CO2, and humidity, the NU-5710 ensures optimal conditions for cell proliferation. Its standout feature is the dual decontamination cycles, offering 145°C dry and 95°C humidified options for flexible, thorough decontamination.
Continuous HEPA filtration maintains ISO Class 5 air quality within the chamber, minimizing the risk of contamination. The direct heat technology enables rapid temperature recovery and uniformity, while the user-friendly interface allows for easy monitoring and adjustment of parameters. The NU-5710's advanced sensors and control systems maintain a stable environment even with changing external conditions, enhancing experimental reproducibility. Designed with both performance and convenience in mind, this incubator is an ideal choice for cell culture laboratories prioritizing precise environmental control and effective contamination prevention.
Effortless Overnight Decontamination
Experience hassle-free contamination control with our Direct Heat Technology, featuring an efficient 8-hour overnight decontamination cycle at 145°C dry and 95°C humidified settings. This advanced system allows you to run full decontamination without removing CO2 or temperature sensors, ensuring minimal downtime. The intuitive NuTouch control system guides you through each phase with on-screen instructions and progress updates, simplifying the entire process and enhancing your laboratory workflow.
Advanced Contamination Control for Optimal Cell Culture Integrity
Enhance your cell culture protection with In-VitroCell's Constant Contamination Control. This advanced system merges continual HEPA filtration with high heat decontamination to maintain an ISO Class 5 clean air environment and slight positive pressure inside the chamber. By consistently cycling air through an external HEPA filter, In-VitroCell ensures a robust, multi-layered defense against contamination, safeguarding the integrity and vitality of your cell cultures.
Easy to Clean Chamber
Optimize cleanability with NuAire CO2 Incubators, showcasing a crevice-free interior and coved corners. Their streamlined design facilitates easy cleaning, effectively minimizing contamination risks for a reliably pristine research environment.
Precision CO2 Control with Minimal Drift
NuAire's CO2 Incubators feature a cutting-edge dual wave infrared (IR) sensor meticulously engineered for precise CO2 level control within the growth chamber. This innovative sensor uses unique wavelengths absorbed exclusively by CO2, ensuring accurate measurements unaffected by other elements like water vapor. Its advanced design promises stable output with minimal drift, reducing the need for frequent recalibrations and maintaining optimal pH levels for superior cell culture conditions.
Specifications
| Access Port Location | Right Side |
| Chamber Air Filter | 99.97% Efficiency @ ≥ 0.3 Micron Capsule Filter Located in Sensor Bay |
| Exterior Door Seal | Magnetic Outer Door Gasket |
| Exterior Material | Cold Rolled 16 & 18 Gauge Steel, Finished in Powder Coated Polyurethane Finish |
| In-line Gas Filters | 99.97% Efficiency @ ≥ 0.3 Micron Disk Filters for Gas & Air Supplies, Disk Filter for CO2 Sensor |
| Insulation | High Density Insulation with High "R" Rating |
| Interior Door Seal | Silicone Rubber Gasket |
| Interior Material | Highly Polished Type 304L 16 Gauge Stainless Steel |
| Sample Port Location | Inner Glass Door |
| Shelf Capacity | 25 lbs per Shelf / 125 lbs per Incubator |
| Shelf Material | Stainless Steel |
| Data Output Features | RS-485, USB, 4-20mA |
| Remote Alarm Terminals | Standard |
| Exterior Depth Inches (mm) | 27.500 (699) |
| Exterior Height Inches (mm) | 36.188 (894) |
| Exterior Width Inches (mm) | 25.500 (648) |
| Footprint Depth inches (mm) | 20.825 (530) |
| Footprint Width inches (mm) | 22.625 (575) |
| Interior Depth Inches (mm) | 20.678 (525) |
| Interior Height Inches (mm) | 24.000 (610) |
| Interior Volume Cubic Feet (Liters) | 5.65 (160) |
| Interior Width Inches (mm) | 20.250 (514) |
| Shelf Depth Inches (mm) | 18 3/4 (476) |
| Shelf Width Inches (mm) | 18 (457) |
| Water Pan Depth | 1.5 (38) |
| Water Pan Length Inches (mm) | 12 (305) |
| Water Pan Width | 10 (254) |
| Electrical Configuration | 115V, 60Hz |
| Power Cord Length Foot (Meter) | 8 (2.5) |
| Safety Certification | UL, UL-C |
| Safety Certification | UL-C,US,CE,UKCA |
| Chamber Air Circulation Method | Air Pump |
| Chamber Jacket Technology | Air Jacket via Two Axial Fans Drawing Air into Shell |
| Control System | NuTouch |
| Chamber Heater(s) Location | Sides, Bottom, Top and Back of Chamber |
| Door and Perimeter Heater Control Logic | Base Duty Cycle set to chamber temperature Set-Point, Proportional 0-100% [manually adjustable] |
| Temperature Accuracy | ± 0.1% |
| Temperature Control | Direct Heat |
| Temperature Control Range | 5°C above ambient (to a 30°C max ambient) to 55°C |
| Temperature Display Resolution | 0.1°C |
| Temperature Recovery | 0.12°C/min. on Average |
| Temperature Sensor Type | Precision Integrated Circuit |
| Temperature Set-Point Range | 5°C to 55°C (37.0°C Default) |
| Temperature Uniformity | ± 0.35°C @ 37°C |
| Net Weight lbs (kg) | 220 (100) |
| Access Port Location | Right Side |
| Chamber Air Filter | 99.97% Efficiency @ ≥ 0.3 Micron Capsule Filter Located in Sensor Bay |
| Exterior Door Seal | Magnetic Outer Door Gasket |
| Exterior Material | Cold Rolled 16 & 18 Gauge Steel, Finished in Powder Coated Polyurethane Finish |
| In-line Gas Filters | 99.97% Efficiency @ ≥ 0.3 Micron Disk Filters for Gas & Air Supplies, Disk Filter for CO2 Sensor |
| Insulation | High Density Insulation with High "R" Rating |
| Interior Door Seal | Silicone Rubber Gasket |
| Interior Material | Highly Polished Type 304L 16 Gauge Stainless Steel |
| Sample Port Location | Inner Glass Door |
| Shelf Capacity | 25 lbs per Shelf / 125 lbs per Incubator |
| Shelf Material | Stainless Steel |
| Data Output Features | RS-485, USB, 4-20mA |
| Remote Alarm Terminals | Standard |
| Exterior Depth Inches (mm) | 27.500 (699) |
| Exterior Height Inches (mm) | 36.188 (894) |
| Exterior Width Inches (mm) | 25.500 (648) |
| Footprint Depth inches (mm) | 20.825 (530) |
| Footprint Width inches (mm) | 22.625 (575) |
| Interior Depth Inches (mm) | 20.678 (525) |
| Interior Height Inches (mm) | 24.000 (610) |
| Interior Volume Cubic Feet (Liters) | 5.65 (160) |
| Interior Width Inches (mm) | 20.250 (514) |
| Shelf Depth Inches (mm) | 18 3/4 (476) |
| Shelf Width Inches (mm) | 18 (457) |
| Water Pan Depth | 1.5 (38) |
| Water Pan Length Inches (mm) | 12 (305) |
| Water Pan Width | 10 (254) |
| Electrical Configuration | 230V, 50/60Hz |
| Power Cord Length Foot (Meter) | 8 (2.5) |
| Safety Certification | UL, UL-C |
| Safety Certification | UL-C,US,CE,UKCA |
| Chamber Air Circulation Method | Air Pump |
| Chamber Jacket Technology | Air Jacket via Two Axial Fans Drawing Air into Shell |
| Control System | NuTouch |
| Chamber Heater(s) Location | Sides, Bottom, Top and Back of Chamber |
| Door and Perimeter Heater Control Logic | Base Duty Cycle set to chamber temperature Set-Point, Proportional 0-100% [manually adjustable] |
| Temperature Accuracy | ± 0.1% |
| Temperature Control | Direct Heat |
| Temperature Control Range | 5°C above ambient (to a 30°C max ambient) to 55°C |
| Temperature Display Resolution | 0.1°C |
| Temperature Recovery | 0.12°C/min. on Average |
| Temperature Sensor Type | Precision Integrated Circuit |
| Temperature Set-Point Range | 5°C to 55°C (37.0°C Default) |
| Temperature Uniformity | ± 0.35°C @ 37°C |
| Net Weight lbs (kg) | 220 (100) |