In-VitroCell NU-8631 Water Jacket CO2 Incubator
Model NU-8631 is a Water Jacket CO2 Incubator featuring an Oxygen monitoring and control system to suppress Oxygen levels in the growth chamber by injecting Nitrogen for hypoxia research.
- Overview
- Specifications
- Reviews
- Resources
- Options
Overview
The In-VitroCell CO2 Incubator Model NU-8631 is a beacon of innovation for Lab Managers, Principal Investigators, and Laboratory Technicians striving for excellence in cell culture applications. Its design integrates a water jacket, heater, and precise temperature probes to regulate the growth chamber's environment expertly. This model shines in tasks that demand strict control over oxygen levels, offering specialized capabilities for maintaining suppressed oxygen levels or hypoxic conditions. Oxygen is meticulously monitored via an advanced sensor, and nitrogen gas is injected as needed to reach the desired setpoint. This incubator is not just about maintaining optimal conditions; it's about ease of use and peace of mind. With a user-friendly interface, superior filtration system, and continuous monitoring of chamber conditions, the NU-8631 guarantees that your cell cultures, particularly in critical areas such as stem cell and age-related research, are nurtured in an environment where precision meets protection. The NU-8631 is more than an incubator; it is a pivotal tool in advancing scientific discovery and research excellence.
Optimize Cell Growth with Precision Oxygen Control
For labs focusing on sensitive cell cultures prone to stress and DNA damage, our CO2 Incubators with Oxygen Control are a game-changer. Featuring an advanced O2 sensor, these incubators meticulously monitor and regulate oxygen levels within the growth chamber. By injecting Nitrogen (N2) gas to adjust oxygen to the desired set point, they cater to a wide range of research applications, including studies on the brain, eyes, liver, heart, and kidneys. This precise oxygen control is crucial for maintaining the integrity and health of delicate cell lines, making it an indispensable tool for Lab Managers, Principal Investigators, and Laboratory Technicians dedicated to groundbreaking cell culture work.
Advanced IR Sensor for Precise CO2 Control
Designed for laboratory excellence, our single-source dual wave infrared (IR) sensor expertly controls CO2 levels within the growth chamber, ensuring an optimal pH environment for cell culture success. Utilizing specific wavelengths absorbed exclusively by CO2, this sensor delivers highly accurate measurements unaffected by other components like water vapor. Its advanced design results in a stable output, minimizing drift and reducing the frequency of calibrations. With this state-of-the-art technology, managing the delicate balance of CO2 in your growth chamber becomes more reliable and efficient, enhancing the quality of your cell culture work.
Optimal Temperature Control with Water Jacket Incubation
The In-VitroCell Water Jacket CO2 Incubators are a cornerstone for precise cell culture growth, featuring an expansive 18-gallon (68.1-liter) water jacket. This innovative design envelops the inner chamber, ensuring a uniformly maintained temperature within ±0.2°C. Enhancing this stability, the R5 insulation along the outer chamber walls significantly reduces heat loss. The microprocessor-controlled door and perimeter heaters adeptly respond to ambient room temperatures. These heaters can be manually adjusted up to ±20 percent, providing added control to mitigate condensation within the growth chamber. With the In-VitroCell Water Jacket CO2 Incubators, you can trust an environment that fosters optimal cell growth and development.
Superior Cleanability with Smooth Design
Crafted for the meticulous needs of Lab Managers, Principal Investigators, and Laboratory Technicians, the growth chamber of our CO2 incubator is a model of hygienic design. It features a crevice-free architecture constructed from robust 16 gauge, type 304L polished stainless steel. This thoughtful design ensures that every inch of the chamber walls is smooth, complete with rounded corners for more efficient cleaning. This eliminates the hard-to-reach spots often found in conventional 90-degree corners, making maintaining a contaminant-free environment for sensitive cell cultures easier. The added convenience of easily removable shelving, supports, and guide rails, all autoclavable, underscores our commitment to providing a cell culture incubator that meets and exceeds the stringent standards required in scientific research settings.
Specifications
CO2 Accuracy | ± 0.1% |
CO2 Control Logic | Fixed Algorithm/Manual, Environmental Adaptable |
CO2 Display Resolution | 0.1% |
CO2 Range | 0.1 to 20%, 5% Default Set Point |
CO2 Recovery | Up to 5% ± 0.2% / -0.5 in 5 minutes Average |
CO2 Sensor Type | Infrared (NDIR) |
Segmented Doors | Optional Set of 4 Inner Doors |
Access Port Location | Right Side |
Chamber Air Filter | 99.97% Efficiency @ ≥ 0.3 Micron Capsule Filter Located in Sensor Bay |
Exterior Door Seal | Magnetic Outer Door Gasket |
Exterior Material | 16 Gauge Steel with Textured Polyurethane Finish |
In-line Gas Filters | 99.97% Efficiency @ ≥ 0.3 Micron Disk Filters for Gas & Air Supplies, Disk Filter for CO2 Sensor |
Inner Doors | One Standard, Sectional optional |
Insulation | Insulation with R5.0 Rating |
Interior Door Seal | Silicone Rubber Gasket |
Interior Material | Polished Type 304L 16 Gauge Stainless Steel |
Sample Port Location | Inner Glass Door |
Shelf Capacity lbs (kg) | 25 lbs per Shelf / 125 lbs per Incubator |
Shelf Material | Stainless Steel or Copper Alloy |
Shelves | 4 Shelves Supplied, 16 Shelves Maximum Capacity |
Data Output Features | RS-485, USB, 4-20mA |
Remote Alarm Terminals | Standard |
Est. Shipping Depth Inches (mm) | 33 (838) |
Est. Shipping Height Inches (mm) | 49 (1245) |
Est. Shipping Width Inches (mm) | 31 (787) |
Exterior Depth Inches (mm) | 27 (685) |
Exterior Height Inches (mm) | 37.75 (958) |
Exterior Width Inches (mm) | 25.625 (649) |
Footprint Depth inches (mm) | 17.5 (445) |
Footprint Width inches (mm) | 22 (557) |
Interior Depth Inches (mm) | 20.625 (524) |
Interior Height Inches (mm) | 24 (611) |
Interior Volume Cubic Feet (Liters) | 5.65 (160) |
Interior Width Inches (mm) | 20.375 (518) |
Shelf Depth Inches (mm) | 18 3/4 (476) |
Shelf Width Inches (mm) | 18 (457) |
Water Pan Depth | 1.5 (38) |
Water Pan Length Inches (mm) | 12 (305) |
Water Pan Width | 10 (254) |
Electrical Configuration | 115V 60Hz |
Power Cord Length Foot (Meter) | 8 (2.5) |
Safety Certification | UL, UL-C, UK CA |
O2 Accuracy | ± 0.25% |
O2 Control Logic | Fixed algorithm/ manual environmental adaptable |
O2 Display Resolution | 0.1% |
O2 Measuring Range | 0 - 25% |
O2 Recovery | 5.0 ± 0.5% twenty minutes on Average |
O2 Sensor Type | Zirconia Ceramic |
O2 Set Point Range | 0.5 -21.0% (ambient) (21.0% Default) |
Decontamination Cycle | Not available |
RH Control Method | Water Pan |
RH Water Pan Capacity | 2L (Recommended Fill 1.5L) |
Chamber Air Circulation Method | Air Pump |
Chamber Jacket Technology | Water Jacket, 18 Gallon (68-Liter) |
Control System | NuTouch |
Chamber Heater(s) Location | Bottom of Chamber |
Door and Perimeter Heater Control Logic | Base Duty Cycle set to chamber temperature Set-Point, Proportional 0-100% [manually adjustable] |
Temperature Accuracy °C | ± 0.1% |
Temperature Control | Water Jacket |
Temperature Control Range | 5°C above ambient (to a 30°C max ambient) to 55°C |
Temperature Display Resolution | 0.1°C |
Temperature Recovery | 0.12°C/min. on Average |
Temperature Sensor Type | Precision Integrated Circuit |
Temperature Set-Point Range | 5°C to 55°C (37.0°C Default) |
Temperature Uniformity °C | ± 0.20°C @ 37°C |
Est. Shipping Weight lbs (kg) | 370 (168) |
Net Weight lbs (kg) | 403 (183) includes full water jacket and shelves |
CO2 Accuracy | ± 0.1% |
CO2 Control Logic | Fixed Algorithm/Manual, Environmental Adaptable |
CO2 Display Resolution | 0.1% |
CO2 Range | 0.1 to 20%, 5% Default Set Point |
CO2 Recovery | Up to 5% ± 0.2% / -0.5 in 5 minutes Average |
CO2 Sensor Type | Infrared (NDIR) |
Segmented Doors | Optional Set of 4 Inner Doors |
Access Port Location | Right Side |
Chamber Air Filter | 99.97% Efficiency @ ≥ 0.3 Micron Capsule Filter Located in Sensor Bay |
Exterior Door Seal | Magnetic Outer Door Gasket |
Exterior Material | 16 Gauge Steel with Textured Polyurethane Finish |
In-line Gas Filters | 99.97% Efficiency @ ≥ 0.3 Micron Disk Filters for Gas & Air Supplies, Disk Filter for CO2 Sensor |
Inner Doors | One Standard, Sectional optional |
Insulation | Insulation with R5.0 Rating |
Interior Door Seal | Silicone Rubber Gasket |
Interior Material | Polished Type 304L 16 Gauge Stainless Steel |
Sample Port Location | Inner Glass Door |
Shelf Capacity lbs (kg) | 25 lbs per Shelf / 125 lbs per Incubator |
Shelf Material | Stainless Steel or Copper Alloy |
Shelves | 4 Shelves Supplied, 16 Shelves Maximum Capacity |
Data Output Features | RS-485, USB, 4-20mA |
Remote Alarm Terminals | Standard |
Est. Shipping Depth Inches (mm) | 33 (838) |
Est. Shipping Height Inches (mm) | 49 (1245) |
Est. Shipping Width Inches (mm) | 31 (787) |
Exterior Depth Inches (mm) | 27 (685) |
Exterior Height Inches (mm) | 37.75 (958) |
Exterior Width Inches (mm) | 25.625 (649) |
Footprint Depth inches (mm) | 17.5 (445) |
Footprint Width inches (mm) | 22 (557) |
Interior Depth Inches (mm) | 20.625 (524) |
Interior Height Inches (mm) | 24 (611) |
Interior Volume Cubic Feet (Liters) | 5.65 (160) |
Interior Width Inches (mm) | 20.375 (518) |
Shelf Depth Inches (mm) | 18 3/4 (476) |
Shelf Width Inches (mm) | 18 (457) |
Water Pan Depth | 1.5 (38) |
Water Pan Length Inches (mm) | 12 (305) |
Water Pan Width | 10 (254) |
Electrical Configuration | 230V 50/60Hz |
Power Cord Length Foot (Meter) | 8 (2.5) |
Safety Certification | UL, UL-C, UK CA |
O2 Accuracy | ± 0.25% |
O2 Control Logic | Fixed algorithm/ manual environmental adaptable |
O2 Display Resolution | 0.1% |
O2 Measuring Range | 0 - 25% |
O2 Recovery | 5.0 ± 0.5% twenty minutes on Average |
O2 Sensor Type | Zirconia Ceramic |
O2 Set Point Range | 0.5 -21.0% (ambient) (21.0% Default) |
Decontamination Cycle | Not available |
RH Control Method | Water Pan |
RH Water Pan Capacity | 2L (Recommended Fill 1.5L) |
Chamber Air Circulation Method | Air Pump |
Chamber Jacket Technology | Water Jacket, 18 Gallon (68-Liter) |
Control System | NuTouch |
Chamber Heater(s) Location | Bottom of Chamber |
Door and Perimeter Heater Control Logic | Base Duty Cycle set to chamber temperature Set-Point, Proportional 0-100% [manually adjustable] |
Temperature Accuracy °C | ± 0.1% |
Temperature Control | Water Jacket |
Temperature Control Range | 5°C above ambient (to a 30°C max ambient) to 55°C |
Temperature Display Resolution | 0.1°C |
Temperature Recovery | 0.12°C/min. on Average |
Temperature Sensor Type | Precision Integrated Circuit |
Temperature Set-Point Range | 5°C to 55°C (37.0°C Default) |
Temperature Uniformity °C | ± 0.20°C @ 37°C |
Est. Shipping Weight lbs (kg) | 370 (168) |
Net Weight lbs (kg) | 403 (183) includes full water jacket and shelves |
Review
Resources
Brochures
Drawings
Request Your Quote for a NU-8631
Please fill out the form below for a lab equipment quote and we'll get to work on getting you what you need. Need to talk with someone right away? Give us a call at 763-553-1270.
Thank you for completing the form.
We will be in touch. If you have any urgent questions, please reach out at 763-553-1270.