In-VitroCell NU-5841 Direct HeatCO2 Incubator
The In-VitroCell ES NU-5841 provides an easy method to monitor and control humidity and oxygen levels in the chamber for hypoxic stress studies, stem cell culture, carcinogenic tumors, toxicity, and more.
The In-VitroCell ES NU-5841 provides an easy method to monitor and control humidity and oxygen levels in the chamber for hypoxic stress studies, stem cell culture, carcinogenic tumors, toxicity, and more.
- Overview
- Specifications
- Resources
Overview
The In-VitroCell NU-5841 represents a state-of-the-art Direct Heat Hypoxic CO2 Incubator with humidity control that precisely monitors and controls both oxygen and relative humidity levels within its growth chamber. Featuring a generous 200-liter chamber capacity, the NU-5841 is ideal for hypoxic stress studies, stem cell culture, carcinogenic tumor research, toxicity studies, and more. Its advanced Zirconia Ceramic O2 sensor and precision humidity controls provide the environmental stability essential for sensitive cell culture applications.
Specifications
| Segmented Doors | Optional Set of 6 Inner Doors, 2 Across by 3 Down |
| Access Port Location | Right Side |
| Chamber Air Filter | 99.97% Efficiency @ ≥ 0.3 Micron Capsule Filter Located in Sensor Bay |
| Exterior Door Seal | Magnetic Outer Door Gasket |
| Exterior Material | Cold Rolled 16 & 18 Gauge Steel, Finished in Powder Coated Polyurethane Finish |
| In-line Gas Filters | 99.97% Efficiency @ ≥ 0.3 Micron Disk Filters for Gas & Air Supplies, Disk Filter for CO2 Sensor |
| Inner Doors | One |
| Insulation | High Density Insulation with High R Rating |
| Interior Door Seal | Silicone Rubber Gasket |
| Interior Material | Polished Type 304L 16 Gauge Stainless Steel |
| Sample Port Location | Inner Glass Door |
| Shelf Capacity lbs (kg) | 25 lbs per Shelf / 125 lbs per Incubator |
| Shelf Material | Stainless Steel or Copper Alloy |
| Shelves | 4 Shelves Supplied, 20 Shelves Maximum Capacity |
| Data Output Features | RS-485, USB, 4-20mA |
| Remote Alarm Terminals | Standard |
| Est. Shipping Depth Inches (mm) | 31 (787) |
| Est. Shipping Height Inches (mm) | 51 (1219) |
| Est. Shipping Width Inches (mm) | 31 (787) |
| Exterior Depth Inches (mm) | 27.188 (691) |
| Exterior Height Inches (mm) | 39.688 (1008) |
| Exterior Width Inches (mm) | 26.750 (680) |
| Footprint Depth inches (mm) | 20.75 (527) |
| Footprint Width inches (mm) | 23.75 (603) |
| Interior Depth Inches (mm) | 20.053 (509) |
| Interior Height Inches (mm) | 28.500 (724) |
| Interior Volume Cubic Feet (Liters) | 7.06 (200) |
| Interior Width Inches (mm) | 21.257 (540) |
| Shelf Depth Inches (mm) | 18 3/4 (476) |
| Shelf Width Inches (mm) | 19 3/4 (502) |
| Water Pan Depth | 1.5 (38) |
| Water Pan Length Inches (mm) | 12 (305) |
| Water Pan Width | 10 (254) |
| Electrical Configuration | 115V 60Hz |
| Power Cord Length Foot (Meter) | 8 (2.5) |
| Safety Certification | UL, UL-C |
| O2 Accuracy | ± 0.25% |
| O2 Control Logic | Fixed algorithm/ manual environmental adaptable |
| O2 Display Resolution | 0.1% |
| O2 Measuring Range | 0 - 25% |
| O2 Recovery | 5.0 ± 0.5% twenty minutes on Average |
| O2 Sensor Type | Zirconia Ceramic |
| O2 Set Point Range | 0.5 -21.0% (ambient) (21.0% Default) |
| Decontamination Cycle | 95°C Humidified Decontamination, 145°C Dry Decontamination Cycle |
| RH Accuracy | +5% /- 3% |
| RH Control Logic | Fixed algorithm/manual environmental adaptable |
| RH Control Method | Water Pan or Evaporator Box, Depending on Model |
| RH Control Range | Ambient dependent to 90% |
| RH Display Resolution | 0.1% |
| RH Evaporator Box Capacity | 3L |
| RH Recovery | 90% +5%/-3% within 25 minutes on average |
| RH Sensor Type | Precision capacitance bulk-polymer |
| RH Water Pan Capacity | 2L (Recommended Fill 1.5L) (For Calibration Only) |
| Chamber Air Circulation Method | Air Pump |
| Chamber Jacket Technology | Air Jacket via One or Two Axial Fans Drawing Air into Shell |
| Control System | NuTouch |
| Chamber Heater(s) Location | Walls, Top and Bottom of Chamber |
| Door and Perimeter Heater Control Logic | Base Duty Cycle set to chamber temperature Set-Point, Proportional 0-100% [manually adjustable] |
| Temperature Accuracy °C | ± 0.1% |
| Temperature Control | Direct Heat |
| Temperature Control Range | 5°C above ambient (to a 30°C max ambient) to 55°C |
| Temperature Display Resolution | 0.1°C |
| Temperature Recovery | 0.12°C/min. on Average |
| Temperature Sensor Type | Precision Integrated Circuit |
| Temperature Set-Point Range | 5°C to 55°C (37.0°C Default) |
| Temperature Uniformity °C | ± 0.35°C @ 37°C |
| Est. Shipping Weight lbs (kg) | 325 (147) |
| Net Weight lbs (kg) | 235 (106) |
| Segmented Doors | Optional Set of 6 Inner Doors, 2 Across by 3 Down |
| Access Port Location | Right Side |
| Chamber Air Filter | 99.97% Efficiency @ ≥ 0.3 Micron Capsule Filter Located in Sensor Bay |
| Exterior Door Seal | Magnetic Outer Door Gasket |
| Exterior Material | Cold Rolled 16 & 18 Gauge Steel, Finished in Powder Coated Polyurethane Finish |
| In-line Gas Filters | 99.97% Efficiency @ ≥ 0.3 Micron Disk Filters for Gas & Air Supplies, Disk Filter for CO2 Sensor |
| Inner Doors | One |
| Insulation | High Density Insulation with High R Rating |
| Interior Door Seal | Silicone Rubber Gasket |
| Interior Material | Polished Type 304L 16 Gauge Stainless Steel |
| Sample Port Location | Inner Glass Door |
| Shelf Capacity lbs (kg) | 25 lbs per Shelf / 125 lbs per Incubator |
| Shelf Material | Stainless Steel or Copper Alloy |
| Shelves | 4 Shelves Supplied, 20 Shelves Maximum Capacity |
| Data Output Features | RS-485, USB, 4-20mA |
| Remote Alarm Terminals | Standard |
| Est. Shipping Depth Inches (mm) | 31 (787) |
| Est. Shipping Height Inches (mm) | 51 (1219) |
| Est. Shipping Width Inches (mm) | 31 (787) |
| Exterior Depth Inches (mm) | 27.188 (691) |
| Exterior Height Inches (mm) | 39.688 (1008) |
| Exterior Width Inches (mm) | 26.750 (680) |
| Footprint Depth inches (mm) | 20.75 (527) |
| Footprint Width inches (mm) | 23.75 (603) |
| Interior Depth Inches (mm) | 20.053 (509) |
| Interior Height Inches (mm) | 28.500 (724) |
| Interior Volume Cubic Feet (Liters) | 7.06 (200) |
| Interior Width Inches (mm) | 21.257 (540) |
| Shelf Depth Inches (mm) | 18 3/4 (476) |
| Shelf Width Inches (mm) | 19 3/4 (502) |
| Water Pan Depth | 1.5 (38) |
| Water Pan Length Inches (mm) | 12 (305) |
| Water Pan Width | 10 (254) |
| Electrical Configuration | 230V 50/60Hz |
| Power Cord Length Foot (Meter) | 8 (2.5) |
| Safety Certification | UL, UL-C |
| O2 Accuracy | ± 0.25% |
| O2 Control Logic | Fixed algorithm/ manual environmental adaptable |
| O2 Display Resolution | 0.1% |
| O2 Measuring Range | 0 - 25% |
| O2 Recovery | 5.0 ± 0.5% twenty minutes on Average |
| O2 Sensor Type | Zirconia Ceramic |
| O2 Set Point Range | 0.5 -21.0% (ambient) (21.0% Default) |
| Decontamination Cycle | 95°C Humidified Decontamination, 145°C Dry Decontamination Cycle |
| RH Accuracy | +5% /- 3% |
| RH Control Logic | Fixed algorithm/manual environmental adaptable |
| RH Control Method | Water Pan or Evaporator Box, Depending on Model |
| RH Control Range | Ambient dependent to 90% |
| RH Display Resolution | 0.1% |
| RH Evaporator Box Capacity | 3L |
| RH Recovery | 90% +5%/-3% within 25 minutes on average |
| RH Sensor Type | Precision capacitance bulk-polymer |
| RH Water Pan Capacity | 2L (Recommended Fill 1.5L) (For Calibration Only) |
| Chamber Air Circulation Method | Air Pump |
| Chamber Jacket Technology | Air Jacket via One or Two Axial Fans Drawing Air into Shell |
| Control System | NuTouch |
| Chamber Heater(s) Location | Walls, Top and Bottom of Chamber |
| Door and Perimeter Heater Control Logic | Base Duty Cycle set to chamber temperature Set-Point, Proportional 0-100% [manually adjustable] |
| Temperature Accuracy °C | ± 0.1% |
| Temperature Control | Direct Heat |
| Temperature Control Range | 5°C above ambient (to a 30°C max ambient) to 55°C |
| Temperature Display Resolution | 0.1°C |
| Temperature Recovery | 0.12°C/min. on Average |
| Temperature Sensor Type | Precision Integrated Circuit |
| Temperature Set-Point Range | 5°C to 55°C (37.0°C Default) |
| Temperature Uniformity °C | ± 0.35°C @ 37°C |
| Est. Shipping Weight lbs (kg) | 325 (147) |
| Net Weight lbs (kg) | 235 (106) |
Resources
Brochures
Drawings
Videos
Specifications
BIM Revit
Request Your Quote for a NU-5841
Please fill out the form below for a lab equipment quote and we'll get to work on getting you what you need. Need to talk with someone right away? Give us a call at 763-553-1270.