The In-VitroCell NU-5841 represents a state-of-the-art Direct Heat Hypoxic CO2 Incubator with humidity control that precisely monitors and controls both oxygen and relative humidity levels within its growth chamber. Featuring a generous 200-liter chamber capacity, the NU-5841 is ideal for hypoxic stress studies, stem cell culture, carcinogenic tumor research, toxicity studies, and more. Its advanced Zirconia Ceramic O2 sensor and precision humidity controls provide the environmental stability essential for sensitive cell culture applications.

Specifications

NU-5841 Direct Heat CO2 Incubator with Humidity and Oxygen Control
CO2 Accuracy ± 0.1%
CO2 Control Logic Fixed Algorithm/Manual, Environmental Adaptable
CO2 Display Resolution 0.1%
CO2 Range 0.1 to 20%, 5% Default Set Point
CO2 Recovery Up to 5% ± 0.2% / -0.5 in 5 minutes Average
CO2 Sensor Type Infrared (NDIR)
Segmented Doors Optional Set of 6 Inner Doors, 2 Across by 3 Down
Access Port Location Right Side
Chamber Air Filter 99.97% Efficiency @ ≥ 0.3 Micron Capsule Filter Located in Sensor Bay
Exterior Door Seal Magnetic Outer Door Gasket
Exterior Material Cold Rolled 16 & 18 Gauge Steel, Finished in Powder Coated Polyurethane Finish
In-line Gas Filters 99.97% Efficiency @ ≥ 0.3 Micron Disk Filters for Gas & Air Supplies, Disk Filter for CO2 Sensor
Inner Doors One
Insulation High Density Insulation with High R Rating
Interior Door Seal Silicone Rubber Gasket
Interior Material Polished Type 304L 16 Gauge Stainless Steel
Sample Port Location Inner Glass Door
Shelf Capacity lbs (kg) 25 lbs per Shelf / 125 lbs per Incubator
Shelf Material Stainless Steel or Copper Alloy
Shelves 4 Shelves Supplied, 20 Shelves Maximum Capacity
Data Output Features RS-485, USB, 4-20mA
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 31 (787)
Est. Shipping Height Inches (mm) 51 (1219)
Est. Shipping Width Inches (mm) 31 (787)
Exterior Depth Inches (mm) 27.188 (691)
Exterior Height Inches (mm) 39.688 (1008)
Exterior Width Inches (mm) 26.750 (680)
Footprint Depth inches (mm) 20.75 (527)
Footprint Width inches (mm) 23.75 (603)
Interior Depth Inches (mm) 20.053 (509)
Interior Height Inches (mm) 28.500 (724)
Interior Volume Cubic Feet (Liters) 7.06 (200)
Interior Width Inches (mm) 21.257 (540)
Shelf Depth Inches (mm) 18 3/4 (476)
Shelf Width Inches (mm) 19 3/4 (502)
Water Pan Depth 1.5 (38)
Water Pan Length Inches (mm) 12 (305)
Water Pan Width 10 (254)
Electrical Configuration 115V 60Hz
Power Cord Length Foot (Meter) 8 (2.5)
Safety Certification UL, UL-C
O2 Accuracy ± 0.25%
O2 Control Logic Fixed algorithm/ manual environmental adaptable
O2 Display Resolution 0.1%
O2 Measuring Range 0 - 25%
O2 Recovery 5.0 ± 0.5% twenty minutes on Average
O2 Sensor Type Zirconia Ceramic
O2 Set Point Range 0.5 -21.0% (ambient) (21.0% Default)
Decontamination Cycle 95°C Humidified Decontamination, 145°C Dry Decontamination Cycle
RH Accuracy +5% /- 3%
RH Control Logic Fixed algorithm/manual environmental adaptable
RH Control Method Water Pan or Evaporator Box, Depending on Model
RH Control Range Ambient dependent to 90%
RH Display Resolution 0.1%
RH Evaporator Box Capacity 3L
RH Recovery 90% +5%/-3% within 25 minutes on average
RH Sensor Type Precision capacitance bulk-polymer
RH Water Pan Capacity 2L (Recommended Fill 1.5L) (For Calibration Only)
Chamber Air Circulation Method Air Pump
Chamber Jacket Technology Air Jacket via One or Two Axial Fans Drawing Air into Shell
Control System NuTouch
Chamber Heater(s) Location Walls, Top and Bottom of Chamber
Door and Perimeter Heater Control Logic Base Duty Cycle set to chamber temperature Set-Point, Proportional 0-100% [manually adjustable]
Temperature Accuracy °C ± 0.1%
Temperature Control Direct Heat
Temperature Control Range 5°C above ambient (to a 30°C max ambient) to 55°C
Temperature Display Resolution 0.1°C
Temperature Recovery 0.12°C/min. on Average
Temperature Sensor Type Precision Integrated Circuit
Temperature Set-Point Range 5°C to 55°C (37.0°C Default)
Temperature Uniformity °C ± 0.35°C @ 37°C
Est. Shipping Weight lbs (kg) 325 (147)
Net Weight lbs (kg) 235 (106)
CO2 Accuracy ± 0.1%
CO2 Control Logic Fixed Algorithm/Manual, Environmental Adaptable
CO2 Display Resolution 0.1%
CO2 Range 0.1 to 20%, 5% Default Set Point
CO2 Recovery Up to 5% ± 0.2% / -0.5 in 5 minutes Average
CO2 Sensor Type Infrared (NDIR)
Segmented Doors Optional Set of 6 Inner Doors, 2 Across by 3 Down
Access Port Location Right Side
Chamber Air Filter 99.97% Efficiency @ ≥ 0.3 Micron Capsule Filter Located in Sensor Bay
Exterior Door Seal Magnetic Outer Door Gasket
Exterior Material Cold Rolled 16 & 18 Gauge Steel, Finished in Powder Coated Polyurethane Finish
In-line Gas Filters 99.97% Efficiency @ ≥ 0.3 Micron Disk Filters for Gas & Air Supplies, Disk Filter for CO2 Sensor
Inner Doors One
Insulation High Density Insulation with High R Rating
Interior Door Seal Silicone Rubber Gasket
Interior Material Polished Type 304L 16 Gauge Stainless Steel
Sample Port Location Inner Glass Door
Shelf Capacity lbs (kg) 25 lbs per Shelf / 125 lbs per Incubator
Shelf Material Stainless Steel or Copper Alloy
Shelves 4 Shelves Supplied, 20 Shelves Maximum Capacity
Data Output Features RS-485, USB, 4-20mA
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 31 (787)
Est. Shipping Height Inches (mm) 51 (1219)
Est. Shipping Width Inches (mm) 31 (787)
Exterior Depth Inches (mm) 27.188 (691)
Exterior Height Inches (mm) 39.688 (1008)
Exterior Width Inches (mm) 26.750 (680)
Footprint Depth inches (mm) 20.75 (527)
Footprint Width inches (mm) 23.75 (603)
Interior Depth Inches (mm) 20.053 (509)
Interior Height Inches (mm) 28.500 (724)
Interior Volume Cubic Feet (Liters) 7.06 (200)
Interior Width Inches (mm) 21.257 (540)
Shelf Depth Inches (mm) 18 3/4 (476)
Shelf Width Inches (mm) 19 3/4 (502)
Water Pan Depth 1.5 (38)
Water Pan Length Inches (mm) 12 (305)
Water Pan Width 10 (254)
Electrical Configuration 230V 50/60Hz
Power Cord Length Foot (Meter) 8 (2.5)
Safety Certification UL, UL-C
O2 Accuracy ± 0.25%
O2 Control Logic Fixed algorithm/ manual environmental adaptable
O2 Display Resolution 0.1%
O2 Measuring Range 0 - 25%
O2 Recovery 5.0 ± 0.5% twenty minutes on Average
O2 Sensor Type Zirconia Ceramic
O2 Set Point Range 0.5 -21.0% (ambient) (21.0% Default)
Decontamination Cycle 95°C Humidified Decontamination, 145°C Dry Decontamination Cycle
RH Accuracy +5% /- 3%
RH Control Logic Fixed algorithm/manual environmental adaptable
RH Control Method Water Pan or Evaporator Box, Depending on Model
RH Control Range Ambient dependent to 90%
RH Display Resolution 0.1%
RH Evaporator Box Capacity 3L
RH Recovery 90% +5%/-3% within 25 minutes on average
RH Sensor Type Precision capacitance bulk-polymer
RH Water Pan Capacity 2L (Recommended Fill 1.5L) (For Calibration Only)
Chamber Air Circulation Method Air Pump
Chamber Jacket Technology Air Jacket via One or Two Axial Fans Drawing Air into Shell
Control System NuTouch
Chamber Heater(s) Location Walls, Top and Bottom of Chamber
Door and Perimeter Heater Control Logic Base Duty Cycle set to chamber temperature Set-Point, Proportional 0-100% [manually adjustable]
Temperature Accuracy °C ± 0.1%
Temperature Control Direct Heat
Temperature Control Range 5°C above ambient (to a 30°C max ambient) to 55°C
Temperature Display Resolution 0.1°C
Temperature Recovery 0.12°C/min. on Average
Temperature Sensor Type Precision Integrated Circuit
Temperature Set-Point Range 5°C to 55°C (37.0°C Default)
Temperature Uniformity °C ± 0.35°C @ 37°C
Est. Shipping Weight lbs (kg) 325 (147)
Net Weight lbs (kg) 235 (106)

Options

  • Stainless Steel Chamber with Floor Mounted Water Pan
  • Stainless Steel Chamber with Evaporator Box
  • Copper Alloy Chamber with Floor Mounted Water Pan
  • Copper Alloy Chamber with Evaporator Box
  • Standard Glass Door with Cam Action Lock
  • Sectioned Inner Door with Cam Action Locks (6 Sections, 2 Across by 3 Down)
  • Left Side Door Hinge
  • 115V, 60Hz, 15 Amp, NEMA 5-15P, Made in USA
  • 230V, 50/60 Hz, 15 Amp, Type F or G Plug, Made in USA