Blizzard HC NU-99338J -80°CUltralow Freezer
- Overview
- Specifications
- Resources
Overview
Introducing the Blizzard NU-99338J, an 12 cu. Ft. (341 L) -86°C Ultralow Freezer is expertly designed for laboratories requiring cost-effective, ultra-low temperature storage in a compact form. This freezer utilizes HC refrigerants, ensuring energy-efficient operation. Its robust structure, combining steel walls with composite VIP and polyurethane insulation, guarantees optimal thermal protection. The internal layout features multiple insulated doors and stainless-steel shelves, facilitating easy access while maintaining temperature stability. The front electronic control panel constantly displays running parameters, with a USB port enabling extensive data logging. The NU-99338J is the perfect solution for labs needing reliable, ultra-low-temperature storage in a space-conscious, energy-efficient model.
Reliable Control & Monitoring
Our -86°C ultralow temperature freezer features an eye-level electronic control system, offering clear visibility and easy access to crucial data. This reliable system displays internal and ambient temperatures, voltage levels, and more. In case of any irregularities, it promptly alerts users with audible and visual alarms. Informative indicator lights provide insights into the freezer's condition, including alarms and maintenance needs. User-friendly navigation and a secure passcode feature allow for personalized temperature settings, alarms, and other preferences, ensuring optimal performance and sample safety.
Streamlined Data Export with Integrated USB Port
The integrated USB port makes downloading extensive data effortless. It is ideal for facilities with strict reporting protocols and allows easy access to several years of temperature and operational records.
Enhanced Insulation for Optimal Cold Storage
Revolutionize Cold Storage: This -86°C ultralow temperature freezer boasts state-of-the-art insulation technology. Its main body integrates polyurethane and VIP insulation, providing a formidable barrier to preserve low temperatures. The outer door features a quadruple gasket to prevent cold air loss, complementing a sturdy latch for a secure seal. Inside, the segmented inner doors, each insulated and single-gasket, offer an additional layer of temperature control. Stainless steel shelves, aligned with these segmented doors, allow quick access to specific samples while maintaining the integrity of other compartments.
Specifications
| Access Port Location | Back Wall |
| Back Up Battery for Alarm Functions | High/low temperature, power failure, door open, sensor failure, high ambient temperature, hot condenser, and low battery alarms |
| Cabinet Thickness Inches (mm) | 5 (130) |
| Casters | All-direction caster with fixing stand |
| Door Thickness Inches (mm) | 3.5 (90) |
| Exterior Material | Color Coating Cold Plate Steel |
| Fan Brand | EBM |
| Interior Door Seal | Single Seal on all Interior Doors |
| Shelf Material | Stainless Steel |
| Style | Upright |
| Auto Voltage Safeguard | Included |
| Remote Alarm Terminals | Standard |
| Door Thickness Inches (mm) | 3.5 (90) |
| Exterior Depth Inches (mm) | 35.2 (893) |
| Exterior Depth with Door Open Inches (mm) | 62.8 (1596) |
| Exterior Height Inches (mm) | 72.7 (1846) |
| Exterior Width Inches (mm) | 32 (812) |
| Footprint Depth inches (mm) | 35.2 (893) |
| Footprint Width inches (mm) | 32 (812) |
| Interior Depth Inches (mm) | 24.8 (630) |
| Interior Height Inches (mm) | 45.9 (1165) |
| Interior Width Inches (mm) | 18.3 (465) |
| Electric Protection Type | Class I |
| Electrical Configuration | 230V50Hz |
| Input Power (W) | 920 |
| Power Consumption KWh/day | 7.5 |
| Power Cord | Grounded Three Prong Power Plug, Rated 16A |
| Power Cord Length Foot (Meter) | 8.2 ft (2.5m) |
| Rated Current (A) | 7.5 |
| Rated Frequency (Hz) | 50 |
| Rated Voltage (V) | 230 |
| Stable Current (A) | 4 |
| 1 Min Door Open Recovery Time (25°C ambient running temp -75°C) | 25 |
| Ambient Temperature (°C) | 10 to 32 |
| Cool Down Time | 195 |
| Heat Rejected (BTU/Hour) | 1239 (Average) |
| Safety Certification | UL-C,US, CE, UKCA |
| Compressor Capacity | 950 |
| Compressor Type/Brand/Number | Hermetic Reciprocating Type / SECOP / 2 |
| Condenser Type | Enhanced Micro-Channel & Forced-Air Cooled |
| Defrost Method | Manual |
| Evaporator Type | Cold Wall With Enhanced Heat Transfer Treatment |
| Product Shipping Weight | 612 (278) |
| Temperature Accuracy | ±1 |
| Temperature Control | Microprocessor Controller |
| Temperature Range | -40 to -86 |
| Temperature Sensor Type | RTD (Pt100) |
| Temperature Uniformity | ±5 |
| Access Port Location | Back Wall |
| Back Up Battery for Alarm Functions | High/low temperature, power failure, door open, sensor failure, high ambient temperature, hot condenser, and low battery alarms |
| Cabinet Thickness Inches (mm) | 5 (130) |
| Casters | All-direction caster with fixing stand |
| Door Thickness Inches (mm) | 3.5 (90) |
| Exterior Material | Color Coating Cold Plate Steel |
| Fan Brand | EBM |
| Interior Door Seal | Single Seal on all Interior Doors |
| Shelf Material | Stainless Steel |
| Style | Upright |
| Auto Voltage Safeguard | Included |
| Remote Alarm Terminals | Standard |
| Door Thickness Inches (mm) | 3.5 (90) |
| Exterior Depth Inches (mm) | 35.2 (893) |
| Exterior Depth with Door Open Inches (mm) | 62.8 (1596) |
| Exterior Height Inches (mm) | 72.7 (1846) |
| Exterior Width Inches (mm) | 32 (812) |
| Footprint Depth inches (mm) | 35.2 (893) |
| Footprint Width inches (mm) | 32 (812) |
| Interior Depth Inches (mm) | 24.8 (630) |
| Interior Height Inches (mm) | 45.9 (1165) |
| Interior Width Inches (mm) | 18.3 (465) |
| Electric Protection Type | Class I |
| Electrical Configuration | 220V60Hz |
| Input Power (W) | 1540 |
| Power Consumption KWh/day | 8.2 |
| Power Cord | Grounded Three Prong Power Plug, Rated 16A |
| Power Cord Length Foot (Meter) | 8.2 ft (2.5m) |
| Rated Current (A) | 7.5 |
| Rated Frequency (Hz) | 60 |
| Rated Voltage (V) | 220 |
| Stable Current (A) | 7 |
| 1 Min Door Open Recovery Time (25°C ambient running temp -75°C) | 25 |
| Ambient Temperature (°C) | 10 to 32 |
| Cool Down Time | 195 |
| Heat Rejected (BTU/Hour) | 1166 |
| Safety Certification | UL-C,US, CE, UKCA |
| Compressor Capacity | 950 |
| Compressor Type/Brand/Number | Hermetic Reciprocating Type / SECOP / 2 |
| Condenser Type | Enhanced Micro-Channel & Forced-Air Cooled |
| Defrost Method | Manual |
| Evaporator Type | Cold Wall With Enhanced Heat Transfer Treatment |
| Product Shipping Weight | 612 (278) |
| Temperature Accuracy | ±1 |
| Temperature Control | Microprocessor Controller |
| Temperature Range | -40 to -86 |
| Temperature Sensor Type | RTD (Pt100) |
| Temperature Uniformity | ±5 |
| Access Port Location | Back Wall |
| Back Up Battery for Alarm Functions | High/low temperature, power failure, door open, sensor failure, high ambient temperature, hot condenser, and low battery alarms |
| Cabinet Thickness Inches (mm) | 5 (130) |
| Casters | All-direction caster with fixing stand |
| Door Thickness Inches (mm) | 3.5 (90) |
| Exterior Material | Color Coating Cold Plate Steel |
| Fan Brand | EBM |
| Interior Door Seal | Single Seal on all Interior Doors |
| Shelf Material | Stainless Steel |
| Style | Upright |
| Auto Voltage Safeguard | Included |
| Remote Alarm Terminals | Standard |
| Door Thickness Inches (mm) | 3.5 (90) |
| Exterior Depth Inches (mm) | 35.2 (893) |
| Exterior Depth with Door Open Inches (mm) | 62.8 (1596) |
| Exterior Height Inches (mm) | 72.7 (1846) |
| Exterior Width Inches (mm) | 32 (812) |
| Footprint Depth inches (mm) | 35.2 (893) |
| Footprint Width inches (mm) | 32 (812) |
| Interior Depth Inches (mm) | 24.8 (630) |
| Interior Height Inches (mm) | 45.9 (1165) |
| Interior Width Inches (mm) | 18.3 (465) |
| Electric Protection Type | Class I |
| Electrical Configuration | 115V60Hz |
| Input Power (W) | 935 |
| Power Consumption KWh/day | 7.5 |
| Power Cord | Grounded Three Prong Power Plug, Rated 20A |
| Power Cord Length Foot (Meter) | 8.2 ft (2.5m) |
| Rated Current (A) | 18.0 |
| Rated Frequency (Hz) | 60 |
| Rated Voltage (V) | 115 |
| Stable Current (A) | 6.8 |
| 1 Min Door Open Recovery Time (25°C ambient running temp -75°C) | 25 |
| Ambient Temperature (°C) | 10 to 32 |
| Cool Down Time | 195 |
| Heat Rejected (BTU/Hour) | 1032 |
| Safety Certification | UL-C,US, CE, UKCA |
| Compressor Capacity | 950 |
| Compressor Type/Brand/Number | Hermetic Reciprocating Type / SECOP / 2 |
| Condenser Type | Enhanced Micro-Channel & Forced-Air Cooled |
| Defrost Method | Manual |
| Evaporator Type | Cold Wall With Enhanced Heat Transfer Treatment |
| Product Shipping Weight | 612 (278) |
| Temperature Accuracy | ±1 |
| Temperature Control | Microprocessor Controller |
| Temperature Range | -40 to -86 |
| Temperature Sensor Type | RTD (Pt100) |
| Temperature Uniformity | ±5 |