In-VitroCell NU-8625 Water JacketCO2 Incubator
- Overview
- Specifications
- Resources
Overview
Discover the pinnacle of cell culture growth with the In-VitroCell NU-8625 Water Jacket CO2 Incubator. This state-of-the-art incubator features a sophisticated humidity sensor for monitoring RH levels within its 160-liter stainless steel growth chamber. Enhanced with coved interior corners, the chamber facilitates effortless surface cleaning and decontamination. Accommodating diverse needs, the NU-8625 comes standard with four shelves, offering options in stainless steel, copper alloy, or heavy-duty stainless steel. Precision-engineered to maintain temperature accuracy within 0.1% and equipped with a reliable humidity monitor, the NU-8625 is an ideal solution for sensitive cell lines at risk of desiccation. Its intuitive touch interface allows for seamless control, ensuring your cell cultures thrive under optimal conditions.
Track RH Levels for Optimal Cell Culture Growth
Discover the precision of our humidity monitor in CO2 incubators, tailored for the most sensitive cell cultures. With an advanced RH sensor, it meticulously tracks relative humidity levels up to 90% in the growth chamber. This feature is a boon for lab technicians working with delicate cell cultures susceptible to desiccation. The monitor ensures optimal humidity conditions and allows for real-time tracking. This careful control of the microenvironment is critical in preserving the integrity and viability of your cell cultures, facilitating successful and reproducible results in your scientific endeavors.
Precision Temperature Control in CO2 Incubators
Experience the precision of In-VitroCell Water Jacket CO2 Incubators, expertly designed to maintain a consistent temperature for cell culture growth. The 20-gallon (75.7-liter) water jacket envelops the inner chamber, ensuring uniform temperature distribution within ±0.2°C. Enhanced by R5 insulation, these incubators adeptly minimize heat loss, bolstering efficient temperature maintenance. Equipped with microprocessor-controlled door and perimeter heaters, they adapt to ambient room temperatures with a manual adjustment option of ±20 percent, further reducing condensation for optimal cell culture conditions.
Optimize Cell Growth with Advanced IR Sensor Technology
Experience unparalleled accuracy in mammalian cell culture growth with our cutting-edge IR sensor technology. This sophisticated system precisely regulates CO2 levels in the growth chamber, maintaining the ideal pH for cell cultures. Specially designed to absorb only CO2-specific wavelengths, our sensor ensures measurements are unaffected by extraneous elements like water vapor. The result? A stable, drift-free output that demands fewer calibrations, providing your cell cultures thrive in a consistent and reliable environment.
Minimize Risk with a Crevice-Free Chamber Design
Our meticulously crafted growth chamber enhances cell growth reproducibility in an environment designed to minimize the risk of contamination. The chamber is constructed from 16 gauge, type 304L polished stainless steel and boasts a crevice-free design. Its smooth walls and rounded corners ensure thorough contact with cleaning solutions, surpassing the efficacy of conventional 90-degree corners. This design not only simplifies cleaning but significantly reduces contamination risks. Additionally, the shelving, supports, and guide rails are effortlessly removable, offering the convenience of autoclaving or retaining them during sterilization cycles, ensuring a pristine environment for your cell cultures.
Specifications
| Segmented Doors | Option, Set of 4 Inner Doors |
| Access Port Location | Right Side |
| Chamber Air Filter | 99.97% Efficiency @ ≥ 0.3 Micron Capsule Filter Located in Sensor Bay |
| Exterior Door Seal | Magnetic Outer Door Gasket |
| Exterior Material | 16 Gauge Steel with Textured Polyurethane Finish |
| In-line Gas Filters | 99.97% Efficiency @ ≥ 0.3 Micron Disk Filters for Gas & Air Supplies, Disk Filter for CO2 Sensor |
| Inner Doors | One Standard, Sectional optional |
| Insulation | Insulation with R5.0 Rating |
| Interior Door Seal | Silicone Rubber Gasket |
| Interior Material | Polished Type 304L 16 Gauge Stainless Steel |
| Sample Port Location | Inner Glass Door |
| Shelf Capacity lbs (kg) | 25 lbs per Shelf / 125 lbs per Incubator |
| Shelf Material | Stainless Steel or Copper Alloy |
| Shelves | 4 Shelves Supplied, 16 Shelves Maximum Capacity |
| Data Output Features | RS-485, USB, 4-20mA |
| Remote Alarm Terminals | Standard |
| Est. Shipping Depth Inches (mm) | 33 (838) |
| Est. Shipping Height Inches (mm) | 49 (1245) |
| Est. Shipping Width Inches (mm) | 31 (787) |
| Exterior Depth Inches (mm) | 27 (685) |
| Exterior Height Inches (mm) | 37.75 (958) |
| Exterior Width Inches (mm) | 25.625 (649) |
| Footprint Depth inches (mm) | 17.5 (445) |
| Footprint Width inches (mm) | 22 (557) |
| Interior Depth Inches (mm) | 20.625 (524) |
| Interior Height Inches (mm) | 24 (611) |
| Interior Volume Cubic Feet (Liters) | 5.65 (160) |
| Interior Width Inches (mm) | 20.375 (518) |
| Shelf Depth Inches (mm) | 18 3/4 (476) |
| Shelf Width Inches (mm) | 18 (457) |
| Water Pan Depth | 1.5 (38) |
| Water Pan Length Inches (mm) | 12 (305) |
| Water Pan Width | 10 (254) |
| Electrical Configuration | 115V 60Hz |
| Power Cord Length Foot (Meter) | 8 (2.5) |
| Safety Certification | UL, UL-C, UK CA |
| O2 Accuracy | Not Available |
| O2 Control Logic | Not Available |
| O2 Display Resolution | Not Available |
| O2 Measuring Range | Not Available |
| O2 Recovery | Not Available |
| O2 Sensor Type | Not Available |
| O2 Set Point Range | Not Available |
| Decontamination Cycle | Not available |
| RH Accuracy | +5% / -3% |
| RH Control Method | Water Pan |
| RH Control Range | 0 - 100% (RH) / -40°C - +60°C (Temp) |
| RH Display Resolution | 0.1% |
| RH Sensor Type | Precision capacitance bulk-polymer |
| RH Water Pan Capacity | 2L (Recommended Fill 1.5L) |
| Chamber Air Circulation Method | Air Pump |
| Chamber Jacket Technology | Water Jacket, 20 Gallon (75.7L) |
| Control System | NuTouch |
| Chamber Heater(s) Location | Bottom of Chamber |
| Door and Perimeter Heater Control Logic | Base Duty Cycle set to chamber temperature Set-Point, Proportional 0-100% [manually adjustable] |
| Temperature Accuracy °C | ± 0.1% |
| Temperature Control | Water Jacket |
| Temperature Control Range | 5°C above ambient (to a 30°C max ambient) to 55°C |
| Temperature Display Resolution | 0.1°C |
| Temperature Recovery | 0.12°C/min. on Average |
| Temperature Sensor Type | Precision Integrated Circuit |
| Temperature Set-Point Range | 5°C to 55°C (37.0°C Default) |
| Temperature Uniformity °C | ± 0.20°C @ 37°C |
| Est. Shipping Weight lbs (kg) | 370 (168) |
| Net Weight lbs (kg) | 403 (183) includes full water jacket and shelves |
| Segmented Doors | Option, Set of 4 Inner Doors |
| Access Port Location | Right Side |
| Chamber Air Filter | 99.97% Efficiency @ ≥ 0.3 Micron Capsule Filter Located in Sensor Bay |
| Exterior Door Seal | Magnetic Outer Door Gasket |
| Exterior Material | 16 Gauge Steel with Textured Polyurethane Finish |
| In-line Gas Filters | 99.97% Efficiency @ ≥ 0.3 Micron Disk Filters for Gas & Air Supplies, Disk Filter for CO2 Sensor |
| Inner Doors | One Standard, Sectional optional |
| Insulation | Insulation with R5.0 Rating |
| Interior Door Seal | Silicone Rubber Gasket |
| Interior Material | Polished Type 304L 16 Gauge Stainless Steel |
| Sample Port Location | Inner Glass Door |
| Shelf Capacity lbs (kg) | 25 lbs per Shelf / 125 lbs per Incubator |
| Shelf Material | Stainless Steel or Copper Alloy |
| Shelves | 4 Shelves Supplied, 16 Shelves Maximum Capacity |
| Data Output Features | RS-485, USB, 4-20mA |
| Remote Alarm Terminals | Standard |
| Est. Shipping Depth Inches (mm) | 33 (838) |
| Est. Shipping Height Inches (mm) | 49 (1245) |
| Est. Shipping Width Inches (mm) | 31 (787) |
| Exterior Depth Inches (mm) | 27 (685) |
| Exterior Height Inches (mm) | 37.75 (958) |
| Exterior Width Inches (mm) | 25.625 (649) |
| Footprint Depth inches (mm) | 17.5 (445) |
| Footprint Width inches (mm) | 22 (557) |
| Interior Depth Inches (mm) | 20.625 (524) |
| Interior Height Inches (mm) | 24 (611) |
| Interior Volume Cubic Feet (Liters) | 5.65 (160) |
| Interior Width Inches (mm) | 20.375 (518) |
| Shelf Depth Inches (mm) | 18 3/4 (476) |
| Shelf Width Inches (mm) | 18 (457) |
| Water Pan Depth | 1.5 (38) |
| Water Pan Length Inches (mm) | 12 (305) |
| Water Pan Width | 10 (254) |
| Electrical Configuration | 230V 50/60Hz |
| Power Cord Length Foot (Meter) | 8 (2.5) |
| Safety Certification | UL, UL-C, UK CA |
| O2 Accuracy | Not Available |
| O2 Control Logic | Not Available |
| O2 Display Resolution | Not Available |
| O2 Measuring Range | Not Available |
| O2 Recovery | Not Available |
| O2 Sensor Type | Not Available |
| O2 Set Point Range | Not Available |
| Decontamination Cycle | Not available |
| RH Accuracy | +5% / -3% |
| RH Control Method | Water Pan |
| RH Control Range | 0 - 100% (RH) / -40°C - +60°C (Temp) |
| RH Display Resolution | 0.1% |
| RH Sensor Type | Precision capacitance bulk-polymer |
| RH Water Pan Capacity | 2L (Recommended Fill 1.5L) |
| Chamber Air Circulation Method | Air Pump |
| Chamber Jacket Technology | Water Jacket, 20 Gallon (75.7L) |
| Control System | NuTouch |
| Chamber Heater(s) Location | Bottom of Chamber |
| Door and Perimeter Heater Control Logic | Base Duty Cycle set to chamber temperature Set-Point, Proportional 0-100% [manually adjustable] |
| Temperature Accuracy °C | ± 0.1% |
| Temperature Control | Water Jacket |
| Temperature Control Range | 5°C above ambient (to a 30°C max ambient) to 55°C |
| Temperature Display Resolution | 0.1°C |
| Temperature Recovery | 0.12°C/min. on Average |
| Temperature Sensor Type | Precision Integrated Circuit |
| Temperature Set-Point Range | 5°C to 55°C (37.0°C Default) |
| Temperature Uniformity °C | ± 0.20°C @ 37°C |
| Est. Shipping Weight lbs (kg) | 370 (168) |
| Net Weight lbs (kg) | 403 (183) includes full water jacket and shelves |